Lesson 1 of 3 · Signed curvature and calibration identifiability
Calibrate a bias that follows both charge signs
19 minute lesson · 3 checks along the way
Your goal for this lessonSeparate a common inverse-rigidity offset from a matched opposite-charge signal, and identify the assumptions that make the separation possible.
In this lesson 4 sections · 3 checks
Read & understand
A fitted track still needs a calibrated scale
AMS-02 uses a magnetic field and position measurements to infer the rigidity of charged particles. Rigidity describes momentum per charge, so opposite charge signs bend in opposite directions for comparable incoming motion. A fit can follow its measured detector hits closely yet still give a biased curvature when a coherent detector displacement changes the inferred track shape. The 2023 AMS alignment paper makes this distinction explicit: small spatial residuals alone do not establish the absolute rigidity scale.
Isolate that problem with an original two-equation model. Let κ denote a signed inverse-rigidity coordinate, in GV⁻¹, with the positive and negative samples assigned opposite signs. Suppose carefully matched samples have true coordinates +k and −k, where k is positive. An unknown common additive offset δ shifts both measured coordinates: κ+ = k + δ and κ− = −k + δ. These are hypothetical sample values, not reported AMS calibration constants. The model holds the field convention and matching conditions fixed and isolates one bias mode; it does not represent the detector’s complete alignment algorithm.
Read & understand
Use the midpoint and half-separation for different jobs
Add the two measured coordinates: κ+ + κ− = 2δ. Their signed midpoint therefore gives δ = (κ+ + κ−)/2. Subtract them: κ+ − κ− = 2k. Their half-separation gives k = (κ+ − κ−)/2. A common translation moves the midpoint but leaves the separation unchanged. Taking absolute values before adding would discard the sign information needed to distinguish these two quantities. The algebra works because both samples share the same stipulated k and δ.
For measured coordinates +0.052 and −0.048 GV⁻¹, the midpoint is +0.002 GV⁻¹ and half-separation is 0.050 GV⁻¹. Subtracting the offset gives +0.050 and −0.050 GV⁻¹. Both corrected rigidity magnitudes are 1/0.050 = 20 GV. The uncorrected reciprocal magnitudes would have been approximately 19.231 and 20.833 GV. Their difference is a consequence of the common signed offset, not evidence that the matched true magnitudes were different. Reconstructing the measurements as ±0.050 + 0.002 checks both signs.
NASA frame S134E009289 shows AMS-02 installed on the station’s S3 truss during STS-134 and Expedition 27 operations in May 2011. The complete frame records the instrument’s external setting; its internal particle tracks and calibration measurements require detector data.
Look closely
Which part of a charge-sign measurement cannot be read from this photograph?
See what to notice
The fitted track curvature and its calibration uncertainty come from detector signals and analysis. The photograph shows the mounted instrument and supporting station structures.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Transfer the correction before taking a reciprocal
An alternate matched pair, +0.021 and −0.019 GV⁻¹, gives δ = +0.001 GV⁻¹ and k = 0.020 GV⁻¹, hence a corrected magnitude of 50 GV. The offset has units of inverse rigidity. Subtracting 0.001 from a rigidity measured in GV would mix incompatible quantities. Apply a correction in the coordinate where its model is defined, then transform to the desired output. This order matters because taking a reciprocal is nonlinear.
The same absolute offset can have a larger fractional effect on a smaller inverse rigidity. If a separate fictional pair has true magnitudes of 100 GV, then k = 0.010 GV⁻¹. With δ = +0.002 GV⁻¹, its uncorrected coordinates are +0.012 and −0.008 GV⁻¹, giving apparent magnitudes about 83.333 and 125 GV. Those errors are not equal in percentage magnitude. Near a zero crossing, a reciprocal becomes especially unstable; neither this simplified example nor a small residual proves reliable charge identification there.
Use the midpoint and separation differently
Original two-equation calibration model. The actual AMS absolute-scale analysis compares energy-matched distributions; this diagram is not a detector layout or flight calibration result.
Open full-size diagram in a new tab: Use the midpoint and separation differentlyCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Check what makes the calibration identifiable
One positive sample alone cannot determine both k and δ. A measurement of +0.052 GV⁻¹ fits k = 0.050 with δ = 0.002, but also k = 0.051 with δ = 0.001. The matched negative sample supplies another constraint. If the two true magnitudes differ, however, their midpoint contains both the common offset and the mismatch. More arithmetic cannot repair a missing matching assumption. A correction estimated under the wrong model can look precise while being systematically wrong.
For its absolute-scale determination, the AMS paper compares electron and positron inverse-rigidity distributions at matched calorimeter energy using a likelihood method. Our two values are a teaching simplification of the matching idea, not a reconstruction of that analysis. In the relativistic electron/positron setting, matched energy supports matched momentum magnitude; arbitrary different particle species at the same energy need not meet that condition. Ask separately whether the fit follows the hits, whether the scale is calibrated and whether the samples justify the calibration model. Each conclusion requires its own evidence.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: AMS tracker alignment in spaceSections 8.3.2–8.3.4 distinguish residual alignment from curvature bias and use energy-matched electron/positron distributions. All pairs and offsets in this lesson are invented.
- Read: AMS detector rolesInstitutional overview of complementary charge, momentum, velocity and energy measurements. No current performance guarantee is inferred.