Lesson 2 of 3 · Pointing, battery boundaries and scheduling
Budget energy through pointing and sequence
22 minute lesson · 3 checks along the way
Your goal for this lessonIntegrate pointing-dependent power and follow a capacity-limited battery through a sequence while preserving its reserve.
In this lesson 4 sections · 3 checks
Read & understand
Pointing changes the power available for work
The 2018 AOBA-VELOX IV presentation compares energy budgets for Sun tracking, orbit maintenance and imaging. The planned activities change both consumption and solar collection. A low-power payload can therefore have a larger system cost if its pointing turns useful panel area away from the Sun. The presentation is preflight engineering evidence. Our following single-panel examples are original simplifications, not flight telemetry or a reconstruction of its multi-panel electrical system.
For an illuminated flat panel, assume collected electrical power is P=P0 max(0,cos θ), where θ is the angle between sunlight and the outward panel normal. Let P0=10 watts and treat illumination, temperature and efficiency as constant. At zero degrees, P=10 watts; at 60 degrees, P=5 watts. If the Sun is behind this one-sided panel, this model gives zero rather than negative generation. Reflections, shading by hardware and other panels are excluded.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Integrate energy at a declared electrical boundary
Consider an original 90-minute orbit with 60 minutes of sunlight. Point the panel directly at the Sun for 20 minutes and at 60 degrees for the other 40. Panel energy is 10×20/60+5×40/60=20/3 watt-hours. Assume a single 80% conversion efficiency from panel output to a battery-equivalent accounting boundary, giving 16/3 watt-hours, about 5.333. The eclipse contributes no generation. Watts measure rate; watt-hours measure the amount accumulated over time.
At that same accounting boundary, a three-watt base load for all 90 minutes uses 4.5 watt-hours. An additional 1.2-watt payload for 30 minutes uses 0.6. Total use is 5.1, leaving a net gain of 7/30 watt-hour, about 0.233. All load losses are already included in these stated boundary values, so applying the 80% conversion to them again would double-count a loss. This net total alone does not show whether the battery stays above reserve during every part of the orbit.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Track saturation and reserve in chronological order
Use a separate original battery ledger with capacity ten watt-hours, initial energy eight, and required reserve three. A recharge block R adds four watt-hours; each science block S removes three. Within each block energy changes monotonically, all quantities are at the battery boundary, and excess charge is discarded at capacity. R,S,S gives stored energies 10,7,4: the recharge would have reached twelve, so two are discarded. This order stays above reserve.
S,S,R instead gives 5,2,6. It ends with more energy but crosses below reserve after the second science block. Both schedules have the same nominal net change of minus two watt-hours, yet clipping at capacity and the order of demand produce different outcomes. A valid schedule must respect the whole path, not just its final number. On real hardware, discharge rate, temperature, aging and voltage limits also constrain usable capacity.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Do not spend nameplate capacity twice
For another original estimate, a nominal eight-volt, five-ampere-hour battery corresponds approximately to 40 watt-hours if voltage is treated as constant. Suppose retained capacity is 80% of that estimate and the permitted state-of-charge range is 20% to 90%. The energy between those limits is 40×0.8×0.7=22.4 watt-hours. If only 90% of that reaches a load, the load receives at most 20.16 watt-hours under these assumptions. Keep each boundary visible so a reserve or efficiency is not silently applied twice.
A defensible operations plan combines an attitude timeline, illumination, loads and battery limits, then checks the minimum stored energy through the sequence. Revisit it when a sensor or pointing mode changes. The AOBA-VELOX design comparison supplies the engineering motivation; these cosine, efficiency and ledger exercises do not establish its achieved endurance, actual battery capacity or safe flight commands.
Energy accounting and schedule minima
Original cosine and battery models. Recharge clipping and intermediate minima matter even when the nominal net change is identical.
Open full-size diagram in a new tab: Energy accounting and schedule minimaPut it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: AOBA-VELOX IV: 2018 team design presentationPublic copy of the primary conference presentation. The power-budget slide contrasts pointing modes; the course uses a separately defined, internally balanced model.
- Read: Small Satellite Conference: design paper recordAuthor and conference context. The abstract was reviewed; linked full-paper access was unavailable, so the presentation is the reviewed detailed source.