Lesson 3 of 3 · Retarding potential and cumulative response
Read an ion-energy threshold
22 minute lesson · 3 checks along the way
Your goal for this lessonRecover current in energy intervals while preserving the distinction between a threshold measurement, particle density and the plasma voltage reference.
In this lesson 4 sections · 3 checks
Read & understand
Model the barrier in the ion’s direction of entry
ARCADE carries the Compact Ionospheric Probe developed by National Central University in Taiwan. CIP retains measurement modes of the earlier Advanced Ionospheric Probe, including a retarding potential analyzer. The primary AIP method paper describes increasing a grid’s potential to reject lower-energy positive ions. Its potential reference is the surrounding plasma. We use that principle in an original ideal planar model, rather than transferring AIP operating settings or calibration coefficients to ARCADE.
For singly charged positive ions, an effective barrier of V volts requires normal kinetic energy of at least V electronvolts. Normal means perpendicular to the grid plane. With total energy E and velocity angle θ from that normal, E_normal=E cos²θ because the normal velocity is v cosθ. A 4 eV ion at 60° therefore has only 1 eV normal energy. An ideal 1.5 V barrier rejects it even though its total energy exceeds 1.5 eV.
Read & understand
Read the current as an integral above a threshold
Define j(E) as an ideal collected-current spectrum per normal-energy interval, measured in nA/eV before a known constant transmission factor g. It includes flux weighting; it is not a particle-number density. Let b be a known additive current offset. In our sharp-threshold model, I(V)=b+g∫ᵥ∞j(E)dE, with effective V in volts and the lower energy limit numerically V in eV. Assume steady conditions during the sweep, singly charged ions and no response broadening.
Invent thresholds [0,1,2,3] V and measured currents [7,5.5,3,1] nA, with b=1 nA and g=0.5. Corrected cumulative currents are (I−b)/g=[12,9,4,0] nA. Differences give currents [3,5,4] nA within successive 1 eV intervals. Dividing by interval width gives the same numerical interval averages [3,5,4] nA/eV. These are bin averages, not point samples at the threshold. The fictional dataset stipulates zero collected-current tail above 3 eV.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Keep the offset and voltage origin distinct
A constant b cancels in adjacent current differences, but it remains necessary for the cumulative tail itself. The total above the first threshold is (7−1)/0.5=12 nA, not 14 nA. Transmission g scales both the tail and interval currents. If a terminal current exceeds the calibrated offset, the ideal model has a remaining tail. If it falls below the offset, noise or an inconsistent calibration/model must be considered; a negative result is not a physical negative ion population.
Define V_eff=V_command+ψ, where ψ is the signed reference correction to the surrounding plasma. A positive ψ=0.2 V moves the command interval [1,2] V to normal energies [1.2,2.2] eV. Its width stays 1 eV, so the same current difference gives the same bin average while its energy label changes. This calculation assumes ψ is fixed during the sweep. An uncertain reference can prevent an accurate absolute-energy interpretation even when current differences are precise.
Difference tail currents to recover energy bins
Original ideal response model. The connected points illustrate a piecewise constant bin spectrum; actual grids, angle, species and sheath response require more calibration. Zero current above 3 eV is stipulated.
Open full-size diagram in a new tab: Difference tail currents to recover energy binsCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Change the bin width without changing the units
For an alternate invented sweep, use thresholds [0,2,4,6] V and currents [13,9,3,1] nA, again with b=1 and g=0.5. Corrected tails are [24,16,4,0] nA. Differences [8,12,4] nA occupy 2 eV intervals, giving averages [4,6,2] nA/eV. The middle interval contains 12 nA, not 6 nA. With ψ=−0.3 V, its energy boundaries become [1.7,3.7] eV; subtracting ψ instead of adding it would reverse the stated convention.
The complete AIP response considers species, speed and temperature, with real grid and potential effects requiring calibration. Our bin exercise cannot recover all those quantities or establish particle density from current alone. An ion energetic enough to pass a barrier may still miss the collector or encounter a grid. Similarly, a published instrument principle does not establish a later flight result. Record the response assumptions, voltage reference and available calibration before attaching a physical interpretation to a sweep.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Lin and colleagues: AIP measurement principlesThe April 2017 primary paper, Section 3.2 and Equation 2 on printed page 102, defines retarding response and the plasma potential reference. This is AIP heritage physics, not ARCADE calibration.
- Read: Chiu and colleagues: CIP payload modesThe February 18, 2022 IDEASSat paper, Section 2.2 and Table 5 on pages 7–8, establishes CIP’s AIP heritage and retarding-analyzer mode. IDEASSat results are not attributed to ARCADE.
- Read: NTU: ARCADE mission and instrumentsIdentifies ARCADE/INSPIRESat-4 and the NCU-built CIP. Its planned lower-orbit investigations are not treated as achieved experiments or current operational status.