Lesson 2 of 4 · Calculate energy across operating modes while retaining peak-power and loss limits.
Balance operating modes
8 minute lesson · 3 checks along the way
Your goal for this lessonCalculate energy across operating modes while retaining peak-power and loss limits.
In this lesson 3 sections · 3 checks
Read & understand
Keep watts and watt-hours distinct
Power is the rate at which electrical energy is used. A watt-hour is an amount of energy: one watt sustained for one hour. In a simplified constant-load calculation, multiply power in watts by duration in hours to obtain watt-hours. Add the energy used in different intervals only after expressing every duration in the same unit.
The following original fictional ledger is not an ARGO specification or operating record. A small spacecraft has two non-overlapping modes over one hour: a six-watt active mode for thirty minutes and a two-watt standby mode for thirty minutes. These powers represent the complete listed load in each mode. Do not add the standby load to the active load again.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Build the ledger one interval at a time
Thirty minutes is half an hour. The fictional active interval uses 6 × 0.5 = 3 watt-hours, and the standby interval uses 2 × 0.5 = 1 watt-hour. The listed demand is therefore 4 watt-hours. Over the full hour its average power is four watts, even though its active-mode demand reaches six watts.
If the active mode instead lasts forty-five minutes and standby lasts fifteen, the same fictional loads use 6 × 0.75 + 2 × 0.25 = 5 watt-hours. Moving time into a more demanding mode changes the energy requirement even when neither power rating changes. The schedule is part of the budget.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Check the limits that the total leaves out
Assume an invented battery makes five watt-hours available at its output and the intervening converter delivers eighty percent of that energy to the loads. Only four watt-hours reach the listed loads, exactly matching the first ledger with no reserve. The fictional efficiency is a deliberately fixed teaching assumption. Additional heaters, losses or a longer active interval would require revising the plan.
An energy total does not establish acceptable instantaneous power. Suppose the same fictional bus output can supply at most five watts while active mode asks for six. Enough stored watt-hours would not remove that peak mismatch. A workable revision must address both time-integrated energy and the power required during each mode, then verify the changed configuration.
Check energy and peak power separately
Original fictional ledger: listed loads only; no reserve after conversion.
Open full-size diagram in a new tab: Check energy and peak power separatelyCheck 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: TASA: ARGO program historyInstitutional account of the program, termination and the potential for later use of development work.
- Read: NASA: supporting systems inside a CubeSat busGeneral explanation of bus services; the commercial examples are not ARGO hardware.
- Read: NASA: product realization and reuseGeneral guidance on checking reused products against new uses and environments; not a record of ARGO testing.