Lesson 3 of 3 · Measure the interface you will deliver
Measure the interface you will deliver
22 minute lesson · 3 checks along the way
Your goal for this lessonKeep size, geometry and roughness distinct; propagate machining and net coating growth through a width interval; apply an explicitly stated measurement decision rule.
In this lesson 6 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
A fit check asks a limited question
The study of the InDUS3US-derived 3U printed frame includes a photograph of a ground fit check, with the structure guided into a test jig. That is useful evidence about the demonstrated configuration. It does not show a launch, an orbital deployment or a complete flight-qualification campaign. A fit can be checked while other requirements remain untested. Manufacturing evidence becomes more useful when the team records what was measured, which surfaces were involved, the condition of the part, and the criterion used to make the decision.
Additive manufacturing can create shapes that are awkward to machine directly, but the surfaces that meet another mechanism may still need finishing. The study reports post-machining its critical rails. We will use that interface problem to distinguish three measurements: size between faces, geometry relative to a datum, and surface roughness. Then we will follow an invented width through machining and coating. All process allowances and measurement uncertainties below are classroom inputs, not instructions for fabricating or accepting InDUS3US hardware.
A printed 3U frame undergoing a physical fit check in a test jig, as reported in the 2026 DOST-MIRDC/PhilSA study. This photograph shows a ground fit check, not a flight-qualified spacecraft or an orbital deployment.
Look closely
What can this fit-check photograph establish?
See what to notice
The published image documents the frame inside a ground test jig. A measured friction force, vibration response and flight qualification require separate evidence; they cannot be read from the photograph.
Read & understand
Read the dimension and the datum
A size requirement might state that two outside faces must be between 99.900 and 100.100 mm apart. A parallelism requirement instead constrains the orientation or form of a surface relative to a defined reference, called a datum, within a stated tolerance zone. Roughness describes smaller-scale surface texture using a specified parameter and measurement method. A smooth rail can have the wrong overall width, and a correctly sized part can have unacceptable geometry. Passing one measurement cannot substitute for the others.
JAXA's interface drawing distinguishes 100±0.1-mm dimensions from 0.2-mm geometric tolerance zones and specifies that the values are met after coating. Its rail section separately limits roughness. This distinction also resolves an easy reading error in the manufacturing paper: Table 5's 0.135-mm result is compared with a 0.200-mm parallelism limit, not a 0.100-mm width limit. Read the row's quantity and reference before interpreting 'pass.' Conversely, a fictional width of 100.020 mm can pass its size interval while a separate 0.210-mm parallelism result fails a 0.200-mm limit.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Machining and coating move both faces
Model the outside width between two opposing faces. Let Wraw be the width before finishing, aL and aR the amounts removed from the left and right faces, and gL and gR the net outward growth after the selected coating process. Then Wfinal=Wraw−aL−aR+gL+gR. Each symbol has units of millimetres. Both machined faces reduce the outside width; both outward growth amounts increase it. This is a one-dimensional model, so it cannot establish parallelism, local waviness or the shape of an entire rail.
Net outward growth is deliberately defined here as the change of each external surface. It must not be assumed equal to every coating's total thickness: some processes also change material below the original surface. For a first invented calculation, start at 100.130 mm, remove 0.035 mm from each face and add 0.010 mm outward on each. The result is 100.080 mm. Counting only one face would give the wrong final size. A nominal calculation is still incomplete if the permitted raw dimensions and process amounts vary.
Read & understand
Calculate the full allowed process interval
For a bounded process example, let Wraw=100.100±0.020 mm, each removal be 0.040±0.005 mm, and each net growth be 0.008±0.002 mm. The nominal final width is 100.036 mm. The smallest result combines the smallest raw width, largest removals and smallest growths: 100.080−0.045−0.045+0.006+0.006=100.002 mm. The largest reverses those choices: 100.120−0.035−0.035+0.010+0.010=100.070 mm. The entire allowed interval fits within [99.900,100.100] for this model.
These are allowed ranges, with no probability distribution or cancellation assumption. Their worst effects add in the relevant directions; a square-root-of-squares uncertainty calculation would answer a different question. For an alternate process, use raw 99.930±0.010 mm, removals 0.020±0.003 mm per face and growths 0.008±0.002 mm per face. Its nominal result is 99.906 mm, but its interval is [99.886,99.926]. The nominal width passes while some allowed combinations fall below 99.900 mm. Tightening a process requires attention to the boundary that actually fails.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
A reading near the boundary needs a decision rule
A manufactured part's measured value is not its unknowable exact value. A reported coverage interval describes measurement uncertainty under specified assumptions and coverage; it is not a guarantee that the true value lies inside. JCGM guidance distinguishes tolerance limits from acceptance limits and explains guarded acceptance. For this exercise, explicitly stipulate a decision rule: accept this size measurement only when its entire reported coverage interval lies within [99.900,100.100] mm, including the boundaries. Other agreed rules can manage decision risks differently.
A reading of 100.080 mm with coverage half-width U=0.025 mm gives [100.055,100.105], so we hold it under the stated rule even though the central reading passes. That does not prove the part is oversized. A reading of 99.930±0.020 mm gives [99.910,99.950] and is accepted for this dimension. With fixed U=0.025 mm, acceptable central readings lie from 99.925 to 100.075 mm. This narrower acceptance interval leaves room for the reported coverage on each side. The process range and a measurement coverage interval are different concepts; do not simply count the same variation twice.
Measure the finished interface
Original one-dimensional outside-width model. Growth g means net outward surface change, not assumed total coating thickness. Process bounds are allowed ranges, not statistical uncertainty. Measurement coverage is a separate concept; the stipulated inclusive decision rule does not guarantee zero risk or complete interface qualification. Plotted widths use a shared linear millimetre scale.
Open full-size diagram in a new tab: Measure the finished interfaceCheck 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Report the exact configuration and evidence
Boundary wording changes a decision. Under our inclusive rule, 100.075±0.025 mm just reaches the upper limit and passes; 99.925±0.030 mm reaches 99.895 and is held. A decision report should name the measured quantity, datum where applicable, units, finished-part condition, method, uncertainty and rule. If the part is later coated, reworked or assembled in a way that changes the relevant dimension, the earlier measurement may no longer describe the delivered interface. Preserve that connection between the evidence and its configuration.
The same discipline connects all three lessons. A frame can save mass yet lose yield margin; a lighter mode can move to a lower frequency; a nominal width can pass while its allowed process range or measured coverage does not. None of those results erases the value of a design review or a successful fit check. They identify the next engineering question. Industrial capability grows when people can explain and reproduce these decisions, then obtain the additional evidence required for the actual hardware and its intended use.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: PhilSA: InDUS3US Briefer (2022)Slides 3 and 16–17 connect phased training to mechanical structures and dimensional interfaces. The reproduced interface drawing is historical.
- Read: Padaca et al.: Mass Reduction, Optimization, and Fabrication of a 3 U Nanosatellite Structure Through Advanced Additive Manufacturing Methods (17 June 2026)The printed-frame case connects design heritage, manufacturing and fit measurements. Its conflicting yield claims must not be treated as qualification.
- Read: JAXA: JEM Payload Accommodation Handbook Vol. 8, JX-ESPC-101133-E with E-1 amendmentsConsult the exact interface, configuration and revision: size, datum geometry, finished surfaces, stiffness restraints and load requirements are distinct.
- Read: JCGM 106:2012: The role of measurement uncertainty in conformity assessmentSections 8.1–8.3 distinguish tolerance and acceptance intervals. Our explicitly stated coverage-containment rule is an illustrative decision rule.