Lesson 2 of 3 · Rates, accumulation and missing intervals
Integrate dose through time
12 minute lesson · 3 checks along the way
Your goal for this lessonCalculate accumulated dose from time intervals and bound an incomplete measurement record.
In this lesson 4 sections · 3 checks
Read & understand
Separate a rate from an accumulated quantity
A radiation experiment can ask how much energy was deposited over an interval or how rapidly deposition occurred during part of that interval. These are related questions with different units. A dose rate describes dose per unit time. Accumulated dose adds contributions over time. RADSAT-SK’s radiation-research objective provides a reason to care about the distinction, but the following sequence is an original classroom example and does not describe its sensor design or orbital environment.
Imagine a calibrated detector reporting a constant rate within each of three consecutive intervals. It measures 2 microgray per minute for ten minutes, 8 for five minutes, and 1 for fifteen minutes. A microgray is one thousandth of a milligray. We assume the detector remains sensitive throughout each interval and that each rate represents the whole interval. An instantaneous sample would need additional assumptions before it could stand for several minutes of exposure.
Read & understand
Weight each rate by its duration
For a constant interval, dose equals rate multiplied by time. The first interval contributes 2 × 10 = 20 microgray. The second contributes 8 × 5 = 40, and the third contributes 1 × 15 = 15. Add the contributions to obtain 75 microgray over thirty minutes. The short high-rate interval contributes more than either longer interval, because both rate and duration determine the accumulated quantity.
The time-average rate is total dose divided by total time: 75/30 = 2.5 microgray per minute. Simply averaging the three displayed rates gives (2 + 8 + 1)/3, approximately 3.67. That calculation assigns equal weight to intervals lasting ten, five and fifteen minutes. It answers a different question. When time stamps or interval boundaries are wrong, even individually correct rate values can produce an incorrect accumulated dose.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Keep a gap visible
Now suppose the middle five-minute record is unavailable. The known intervals still contribute 20 + 15 = 35 microgray. A communication gap does not mean the spacecraft stopped experiencing radiation. If independent information justifies a rate between zero and ten microgray per minute throughout the missing interval, its unknown contribution lies between zero and fifty. The total therefore lies between 35 and 85 microgray under those stated bounds.
The complete example’s 75 falls inside that interval, but a real analyst would not know it from the incomplete record alone. Filling the gap with zero chooses the lowest allowed total without evidence. Filling it with a neighboring rate is also an assumption that should be named and tested. If there is no justified upper bound, the received data alone cannot establish a finite upper total. Record missingness explicitly so a later analysis does not mistake it for a measurement.
Add the area under each rate interval
Original rate-and-duration model, not flight measurements. Each rate represents its complete interval. The missing-interval bound requires independent justification for the stated maximum rate.
Open full-size diagram in a new tab: Add the area under each rate intervalCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Check what an onboard accumulator preserves
A separate cumulative counter can sometimes preserve information across a downlink gap. Consider an invented counter that adds one unit per fixed dose increment and wraps from 255 back to zero. It reads 240 before a gap and 14 after it. If other evidence establishes that the increase was less than 256 increments, the change is (14 − 240) modulo 256 = 30. The negative ordinary subtraction is a consequence of the representation, not a negative physical dose.
Without the less-than-256 condition, thirty is not the only possibility: 286 increments produces the same final counter. A reset during the gap would also invalidate this inference. Preserve reset flags, time stamps and counter definitions alongside the values. An accumulated counter may recover a total without revealing when a peak occurred. A student team should decide which scientific questions require interval rates, cumulative readings or both, then test how that evidence survives missing packets and student handovers.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: University of Saskatchewan: RADSAT-SK research objectivesMay 29, 2023 prelaunch account of the dosimeter and melanin-coating investigation. It establishes objectives, not measured shielding performance.
- Read: NIST: applying an instrument calibrationInverse calibration converts response to the measured quantity. Our exact two-point examples omit the fitting and uncertainty work needed with real instruments.