Lesson 4 of 4 · Design a fair image-based dust-removal comparison and distinguish cleared area from mass and functional performance.
Measure dust removal fairly
8 minute lesson · 3 checks along the way
Your goal for this lessonDesign a fair image-based dust-removal comparison and distinguish cleared area from mass and functional performance.
In this lesson 3 sections · 3 checks
Read & understand
Move dust and measure what changed
The Electrodynamic Dust Shield demonstration on Blue Ghost used changing electric fields to transport dust across test surfaces. The instrument-team report describes glass and radiator surfaces with different electrode arrangements and operating modes. A reduster supplied material for the experiment, and cameras and LEDs supported observation.
The report also records a failed LED that caused shadows and nonuniform illumination. This matters because a visual change can arise from the observation system as well as from moved dust. Surface design, dust loading, illumination and the operating sequence all belong with a performance claim.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Define a fictional area metric
Imagine matched images of the same fixed patch, at the same scale and lighting, with a consistent validated dust-classification method. Before treatment, 200 pixels are classified as dust-covered; afterward, 50 are. The reduction in projected dust-covered area is (200 − 50)/200 × 100 = 75%. These invented counts are a teaching example, not the flight experiment’s reported result.
The denominator is the original dust-covered area. Fifty pixels remain, which is 25% of that original area. Neither fraction is automatically the fraction of dust mass removed: particles may differ in thickness, size and overlap. Nor does 75% area reduction establish 75% recovery of radiator heat rejection or optical transmission. Those functions require their own measurements.
Define the dust-removal metric
Original worked example using the lesson’s fictional quantities and stated assumptions.
Open full-size diagram in a new tab: Define the dust-removal metricCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Check controls and transfer conditions
A useful comparison retains an untreated control patch and stable illumination references alongside the treated patch. If both patches brighten after an LED setting changes, brightness alone cannot establish dust removal. Reassess imaging conditions and use a suitable dust metric before attributing the change to the electric field.
Different surface designs and drive modes also complicate a direct ranking. A difference between two tests does not isolate one cause when several factors changed together. A future mission needs evidence under its own material, particle, charging and exposure conditions, plus a measurement of the function it hopes to protect. The demonstration supports further engineering decisions within its tested limits.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.