Lesson 3 of 4 · Use an ideal mixing model to distinguish one volume exchange from complete removal of an initial tracer.
Model a volume exchange
8 minute lesson · 3 checks along the way
Your goal for this lessonUse an ideal mixing model to distinguish one volume exchange from complete removal of an initial tracer.
In this lesson 3 sections · 3 checks
Read & understand
Flow serves several ground-system jobs
The Ares I upper-stage development report describes a proposed purge system that supplied conditioned gas to three compartments before liftoff. Its jobs included environmental control, mixing and cooling avionics. This was development work for the planned upper stage, distinct from the simulator flown on Ares I-X.
A volume-exchange rate tells us how much gas flows through a compartment per unit time. It does not tell us that every original molecule leaves after one exchange. To explore that distinction, use a harmless imaginary tracer and a deliberately simplified mixing model. The calculation is not a launch procedure or a hazardous-gas acceptance criterion.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Follow dilution over successive exchanges
Assume a constant-volume chamber of 12 cubic meters, a constant clean inflow and equal outflow of 3 cubic meters per minute, instantaneous uniform mixing, and no continuing tracer source. Flow and volume use the same local pressure and temperature convention. The exchange time is τ = V/Q = 12/3 = 4 minutes. Because the outflow contains a mixture of old and new gas, removal slows as the tracer concentration falls.
Under these assumptions, the fraction of the initial tracer remaining is C/C₀ = exp(−Qt/V) = exp(−t/τ). The function exp(x) means e raised to x. After four minutes, exp(−1) ≈ 0.368: about 36.8% remains. After twelve minutes, exp(−3) ≈ 0.0498: about 4.98% remains. A 95% reduction therefore takes about three exchange times, not one. All chamber values are fictional; this is not a measurement of an Ares compartment.
An exchanged volume is not a clean sweep
Fictional tracer model · not a hazardous-gas acceptance test.
Open full-size diagram in a new tab: An exchanged volume is not a clean sweepCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Check the assumptions against the hardware
Real compartments can contain poorly mixed pockets, blocked paths or continuing sources. A measurement near one vent need not represent every location. The ideal exponential is useful for reasoning, but local measurements and flow evidence are needed to assess the actual compartment.
NASA’s duct trade illustrates why total flow is not the only design variable: flexible cloth ducts could not keep directed cooling jets sufficiently repeatable. Geometry and rigidity affected where the gas went. Doubling the assumed flow halves τ in our ideal model; it does not, by itself, prove uniform mixing, acceptable temperatures or successful full-system qualification.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.