Lesson 4 of 4 · Injection recovery and masking limits
Test the pipeline with injected signals
20 minute lesson · 3 checks along the way
Your goal for this lessonUse controlled injections and changed masks to test what the complete correction procedure preserves and what it cannot identify.
In this lesson 3 sections · 3 checks
Read & understand
Inject before the correction is refitted
Add a known extra stellar contribution δu to the original y, then refit the nuisance coefficient and repeat the naive sequential analysis. In this linear example the recovered amplitude increases by δ/2. Injecting 2 ppm produces only a 1 ppm increment in the reported stellar amplitude. Compare the injected and uninjected runs; the increment measures recovery of the added signal, rather than confusing it with the original amplitude.
Now place that same 2 ppm injection into r only after the correction has already been performed, and fit u. The reported amplitude increases by the full 2 ppm. That test bypassed the stage that absorbed half the signal. It verifies the final fitting step but overstates recovery through the whole procedure. For this exact linear model, joint fitting recovers the full increment when the injection precedes the fit.
Injection placement changes the test
Original linear exercise, with each increment measured relative to its uninjected run. The accessible table also gives 1 ppm and 4 ppm injections. This tests a particular processing configuration, not every period, phase, amplitude or data-dependent mask.
Open full-size diagram in a new tab: Injection placement changes the testRead diagram data as a table
| Injected amplitude (ppm) | Increment with injection before refitting (ppm) | Increment with injection after correction (ppm) |
|---|---|---|
| 1 | 1/2 | 1 |
| 2 | 1 | 2 |
| 4 | 2 | 4 |
Original linear exercise, with each increment measured relative to its uninjected run. The accessible table also gives 1 ppm and 4 ppm injections. This tests a particular processing configuration, not every period, phase, amplitude or data-dependent mask.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
A quality mask can remove the separating information
Suppose a hypothetical mask retains only samples 0 and 2. Both retained templates become (−1, 1), and the retained measurements are (−5, 5) ppm. The data identify a + b = 5 ppm. They cannot choose between (a, b) = (3, 2), (1, 4), (5, 0) or other pairs with that sum. The determinant is now zero: applying a joint-fitting formula does not restore information that the mask removed.
This is not an argument for keeping corrupt measurements. It is a reason to reassess the inference after justified quality selection. Independent calibration establishing b = 2 ppm would let this restricted example recover a = 3 ppm; if that calibration is uncertain, its uncertainty must also be propagated. Without such evidence, report the combined contribution or limit the claim instead of presenting an arbitrary split as a recovered stellar amplitude.
Masking can remove the separation
Fictional mask, not a recommendation to keep bad measurements. The retained data determine only a + b. An independent exact calibration b = 2 ppm would identify a = 3 ppm; uncertain calibration must carry its own uncertainty.
Open full-size diagram in a new tab: Masking can remove the separationRead diagram data as a table
| a (ppm) | b (ppm) | Sample 0 prediction (ppm) | Sample 2 prediction (ppm) |
|---|---|---|---|
| 3 | 2 | -5 | 5 |
| 1 | 4 | -5 | 5 |
| 5 | 0 | -5 | 5 |
| -2 | 7 | -5 | 5 |
Fictional mask, not a recommendation to keep bad measurements. The retained data determine only a + b. An independent exact calibration b = 2 ppm would identify a = 3 ppm; uncertain calibration must carry its own uncertainty.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Document the recovery test and its limits
An injection test should record the signal shape, amplitude, sampling, insertion stage, flags, fitting method and recovered increment. If clipping or data-dependent masks are part of the real procedure, rerun those decisions too. Testing a single amplitude with a frozen mask does not establish performance for other phases, periods or strengths. Preserve failures as evidence about the method instead of retaining only the injections that look convincing.
Our examples establish specific mathematical facts under declared assumptions: a naive projection can attenuate a real contribution, consistent joint fitting can recover independent templates, and a mask can make the split unidentifiable. They do not confirm a planet, determine a stellar interior or certify the CoRoT pipeline. A scientific interpretation still needs appropriate mission products, documented uncertainties, a defensible physical model and independent checks suited to the claim.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: NASA Exoplanet Archive: CoRoT products and known issuesPrimary data products, channels, observing runs, known issues. Course templates, samples and noise values are fictional teaching examples.
- Read: Auvergne et al.: CoRoT in-flight description and performanceAuthor abstract and bibliographic record only. Course templates, samples and noise values are fictional teaching examples.