Lesson 4 of 4 · Convert pressure difference to panel force and evaluate combined loads against a defined test criterion.
Test heat and pressure together
8 minute lesson · 3 checks along the way
Your goal for this lessonConvert pressure difference to panel force and evaluate combined loads against a defined test criterion.
In this lesson 3 sections · 3 checks
Read & understand
Reproduce more than a temperature
Dyna-Soar skin-panel development used ground tests to examine how hot panels carried loads. Hepler, Backus and Smith describe heat lamps and a vacuum box: reducing pressure on one side creates a pressure difference across the panel. The supports and edge seals had to allow intended thermal movement while transmitting load. A test fixture that imposes the wrong restraint can test a different problem.
The study used repeated heat-and-load cycles before further loading and specified a deflection-based failure criterion. Temperature, duration, load sequence and support condition belong with the result. A specimen can reach its defined failure limit through excessive deformation even if it has not fractured. A ground component test supplies bounded evidence; it does not demonstrate a complete X-20 reentry.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Calculate the force from pressure difference
In a fictional uniform-pressure test, the outside pressure is 100 kilopascals, the box pressure is 80 kilopascals and the exposed panel area is 0.2 square meter. The difference is 20 kilopascals. Net pressure force is difference × area = 20 × 0.2 = 4 kilonewtons, directed toward the lower-pressure side. One kilopascal times one square meter equals one kilonewton.
Using the outside pressure alone would give 20 kilonewtons and ignore the opposing pressure inside the box. Using the box pressure alone would also be wrong. The calculation assumes a uniform pressure difference and the stated exposed area; it is not a stress distribution or a prediction of local bending. All pressures and areas in this exercise are invented.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Evaluate the combined condition
Suppose the fictional panel’s allowable force is 6 kilonewtons at room temperature but only 3 kilonewtons in the specified heated test. A 4-kilonewton load is 2 below the room-temperature limit and 1 above the heated limit. Passing the cool test therefore does not establish a pass under the combined heated load. These invented allowable forces are not material properties or historical qualification limits.
A separate fictional test defines failure as reaching 2 millimeters of center deflection under its stated temperature, duration and support conditions. A panel that reaches that deflection has failed that criterion even without a crack. Record the measured response and criterion together. Changes to the heating profile, exposure time, pressure cycles or fixture may require new evidence before a result can support a different configuration.
Test the combined condition
Original worked example using the lesson’s fictional quantities and stated assumptions.
Open full-size diagram in a new tab: Test the combined conditionCheck 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Hepler, Backus and Smith: Dyna-Soar skin-panel development1960 paper, printed pages 179–183 and figures on 189–190. Heat-lamp and vacuum-box tests preserve support conditions, temperature, load history and a deflection criterion. Exercise pressures and limits are fictional.
- Read: Hepler, Landry and Nelson: Dyna-Soar truss structure1960 paper, printed pages 161–168. Load paths, thermal deformation, joint/member mass and component testing. The primary structure survived the reported tests, while outer skin panels and expansion joints sustained some damage.