Lesson 2 of 3 · Co-location, inverse problems and uncertainty
Retrieve one consistent scene
24 minute lesson · 3 checks along the way
Your goal for this lessonCombine complementary observations of one scene and diagnose incompatible measurements and propagated uncertainty.
In this lesson 4 sections · 3 checks
Read & understand
Match the scene before solving it
EarthCARE combines instruments to estimate an atmospheric state: quantities such as particle type, water content, size and optical properties through a profile. MSI helps describe horizontal variation around the narrow active-sensor track. Co-location means more than attaching the same map coordinate to every value. Viewing direction, acquisition time, footprint and the altitude used to align an oblique view all affect which cloud volume contributes to a measurement.
Imagine a tall cloud above a darker surface. If an oblique radiometer view is matched at the ground while its photons mostly emerge from cloud top, it may be assigned to the wrong part of the scene. Meanwhile the cloud can evolve between views. A retrieval should therefore document its spatial support and alignment assumptions before interpreting disagreement as a physical change. Instrument synergy begins with compatible observations; adding an unrelated measurement can make an estimate worse.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Different sensitivities can break an ambiguity
An original linear example makes the information gain visible. Let x and y be two nonnegative, dimensionless state quantities in one scene. Invent two observations u=x+2y and v=2x+y. These coefficients are teaching choices, not EarthCARE instrument responses. The observation u=4 alone permits several states: (x,y)=(4,0), (2,1) or (0,2). A second observation with a different sensitivity can distinguish them. Repeating u with greater precision would still leave that same ambiguity.
For u=4 and v=5, eliminate one unknown to obtain x=(2v−u)/3=2 and y=(2u−v)/3=1. Both observations are reproduced by one shared state. Averaging 4 and 5 would instead give 4.5, which is neither x nor y and has no interpretation in this model. The real ACM-CAP approach uses a forward model to predict multiple instrument signals from a common atmosphere; its physical relationships and nonlinear responses are much richer than these two equations.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Carry measurement error into the answer
A unique solution is not an exact solution. Suppose u and v have independent, zero-mean errors with standard deviations 0.2 and 0.3 in our dimensionless exercise. Because x=(2v−u)/3, its variance is (4×0.3²+0.2²)/9≈0.04444, giving standard deviation about 0.211. Similarly y has variance (4×0.2²+0.3²)/9≈0.02778 and standard deviation about 0.167. The coefficients are squared when variances are propagated.
The retrieved x and y errors are correlated even though the input errors were independent: their covariance is −2(0.2²+0.3²)/9≈−0.02889. An upward error in u pushes x down and y up. For example, increasing u alone by 0.3 changes x by −0.1 and y by +0.2. Reporting only separate error bars would hide that relationship. In a nonlinear retrieval, observation errors, assumed particle physics and prior constraints all influence the inferred state and its uncertainty.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
A perfect fit can expose incompatible inputs
Now deliberately break co-location. Retain u=4 from the state (2,1), but take v=9 from another scene with state (4,1). Solving as though both observations described one scene gives x=14/3 and y=−1/3. The equations fit exactly, yet the solution violates our declared nonnegative state. The response should be to investigate scene matching, noise and model adequacy. Simply replacing the negative value with zero hides the inconsistency and no longer reproduces both measurements.
Real retrievals may impose positivity or other physical constraints, and an inconsistent result need not prove misalignment specifically. It can also expose a deficient forward model, calibration error or unaccounted uncertainty. The key is to compare predicted and observed signals, retain quality information and test independent evidence. The 2023 ACM-CAP paper demonstrates its method using synthetic atmospheric scenes; those controlled tests support algorithm understanding, while validating flight data requires its own observations and documented conditions.
One scene, two different constraints
Original linear teaching model, not operational radar or lidar coefficients. Both observations must describe the same scene. Error bars summarize a stated independent-input model and do not include real retrieval model error.
Open full-size diagram in a new tab: One scene, two different constraintsPut it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Mason et al.: the ACM-CAP synergistic retrievalSections 1–2 explain a shared atmospheric state, forward models, physical assumptions and uncertainty. The paper evaluates synthetic scenes.
- Read: Wehr et al.: EarthCARE science and system overview2023 instrument design and measurement roles; design requirements are not universal achieved accuracy.
- Read: Velázquez Blázquez et al.: radiance-to-flux conversionThe 2024 BMA-FLX description applies angular models to individual views, then checks and combines their flux estimates.
- Read: Barker et al.: EarthCARE radiative closureSections 2.2–2.3 define effective fluxes and an uncertainty-aware closure assessment; the demonstration uses synthetic observations.