Lesson 1 of 3 · Atmospheric harmonics and observing phases
Fit atmospheric tides without losing the clock
18 minute lesson · 3 checks along the way
Your goal for this lessonRecover the mean, amplitude and phase of an ideal temperature cycle and identify observations that cannot determine all three.
In this lesson 4 sections · 3 checks
Read & understand
Give the temperature cycle a defined clock
Hope’s EMIRS instrument observes the Martian atmosphere in infrared light. A published analysis of its temperature retrievals fits atmospheric tides using time and longitude together. That distinction matters: a repeating variation at one location does not, by itself, identify a wave that follows the Sun around the planet. The Emirates Mars Mission was extended through 2028 in a February 2026 announcement. An approved extension describes the mission plan; it is not a guarantee that every instrument has uninterrupted observations.
Construct an original temperature model at one fixed pressure and latitude: T(t) = M + C cos(2πt) + S sin(2πt). Here t is the fraction of a Martian sol measured from local solar midnight. A 24-hour local clock divides that sol into 24 equal parts; those clock hours are not Earth elapsed hours. Assume a stable cycle, no noise, no changing weather, no longitude dependence and no higher harmonics. M, C and S are temperatures in kelvin. This three-parameter model is a teaching exercise, not the EMIRS retrieval or the paper’s full tidal fit.
Read & understand
Recover coefficients before interpreting a peak
Invent four temperatures at t = 0, 1/4, 1/2 and 3/4: 206, 208, 194 and 192 K. The cosine values are 1, 0, −1, 0; the sine values are 0, 1, 0, −1. Opposite phases therefore give M = (206 + 194)/2 = 200 K and C = (206 − 194)/2 = 6 K. The other pair independently gives M = (208 + 192)/2 = 200 K and S = (208 − 192)/2 = 8 K. Agreement between the two means checks this deliberately exact model.
Rewrite the varying part as A cos(2πt − φ), where A = √(C² + S²) = 10 K. Its maximum occurs at phase φ = atan2(S,C) = 53.1301 degrees, or 3.5420 local clock hours after midnight. The peak temperature is 210 K and the trough is 190 K. Neither 6 K nor 8 K alone is the full amplitude, and the peak-to-trough range is 20 K. The two-argument angle function preserves the quadrant; using an ordinary inverse tangent without checking signs can put the peak half a sol away.
Hope Probe undergoes solar-array testing before launch, as shown in the mission team’s 2022 overview. The photograph shows flight hardware and a ground test setting; it does not show Mars or an atmospheric measurement. Display versions are resized and format-converted without cropping.
Look closely
Which part of Hope’s science still needs evidence beyond this hardware photograph?
See what to notice
The photograph identifies deployed hardware during a ground test. Atmospheric retrievals require calibrated instrument measurements, viewing geometry, and an uncertainty model.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Ask whether the observations can determine the model
Suppose only midnight and noon are observed. Their sine terms are both zero. They still determine M = 200 K and C = 6 K, but any value of S reproduces those two readings. Repeating those same phases a hundred times can reduce random noise if it is independent; it cannot reveal the missing sine component. Setting S to zero would be an extra assumption, not a measured result. Consequently the amplitude and peak time are also undetermined, even with perfectly precise midnight and noon temperatures.
Each observation contributes a row [1, cos(2πt), sin(2πt)] to a linear system. Recovering three coefficients requires three independent directions in those rows, not merely three entries in a file. A measurement at one-quarter sol adds sensitivity to S and resolves the exact example. Closely clustered phases can technically permit a solution while making it highly sensitive to noise. Plan observing times to constrain the whole cycle, and inspect residuals at additional phases rather than celebrating a fit that uses as many unknowns as independent observations.
Recover a cycle from independent phases
Original one-harmonic temperature model. Clock hours divide a Martian sol; they are not Earth elapsed hours. Complete phase coverage and a defined phase convention are essential.
Open full-size diagram in a new tab: Recover a cycle from independent phasesCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Separate a local cycle from a planetary tide
For an alternate cycle, temperatures [205,222,215,198] K at the same phases give M = 210 K, C = −5 K and S = 12 K. The amplitude is 13 K and the maximum occurs at 7.507991 local clock hours; atan2 preserves the second-quadrant phase. The first model predicts 209.899 K at t = 1/8, while this alternate predicts 222.021 K at t = 3/8. These are conditional predictions to test, not additional measured points. Quarter-sol and three-quarter-sol observations alone would leave C unidentified because their cosine terms vanish.
Change the clock origin with t′ = t − 1/4, making zero six local clock hours later. Substituting t = t′ + 1/4 gives C′ = S and S′ = −C. The initial coefficients become [8,−6] K and the maximum wraps to 21.542007 hours; the alternate becomes [12,5] K with maximum 1.507991 hours. Neither amplitude changes. Real EMIRS analysis also treats longitude, vertical response and model sampling explicitly; overlapping seasonal windows share information. A four-point local fit does not establish a migrating wave or a unique heating mechanism. Preserve the clock and observation model when comparing results.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: EMIRS: diurnal temperatures and migrating thermal tidesMethod section 3.2 distinguishes the published longitude/time fit from this original one-harmonic classroom model. Check phase conventions and matched sampling.