Lesson 4 of 4 · MWR wet-path correction and inter-instrument continuity
Carry a delay correction across missions
22 minute lesson · 3 checks along the way
Your goal for this lessonCarry a positive atmospheric excess range into a signed height correction and diagnose an instrument offset that distorts a fitted trend.
In this lesson 4 sections · 3 checks
Read & understand
Support the radar with a different measurement
Envisat’s Microwave Radiometer, MWR, measured microwave brightness temperatures at 23.8 and 36.5 GHz. A central task was to constrain water vapour and cloud liquid water so that their influence on the radar-altimeter measurement could be accounted for. The two channels have different sensitivities, but they do not independently determine every layer in a vertical humidity profile. Background information and a forward model contribute additional constraints. Rain, land within a footprint and surface conditions can complicate interpretation.
The 2017 intercalibration study combines ERS-1, ERS-2 and Envisat observations in a reprocessed record. It examines calibration differences as well as retrieved column water vapour and wet tropospheric correction. This is a useful continuation of Envisat’s scientific record after spacecraft operations ended. Contact was lost on 8 April 2012, and ESA declared the mission ended on 9 May. Later processing can improve interpretation of preserved observations; it does not imply that the spacecraft resumed measurements.
Read & understand
Declare the sign before correcting height
For an original nadir example, let H be satellite altitude relative to a chosen reference, h the surface height, and Rg=H−h the geometric range. Define d as a positive atmospheric excess expressed as one-way-equivalent range. Then Rraw=Rg+d, and the corrected height is h=H−Rraw+d. The delay made the apparent range too long and the uncorrected height too low. Product conventions may store a signed correction differently, so this definition must accompany the calculation.
Choose H=800,000 m, h=10 m and d=0.128 m. The raw range becomes 799,990.128 m. Subtracting it from H alone gives 9.872 m; adding d recovers 10 m. Doubling the correction instead gives 10.128 m and creates an error. Radar time is a round trip, but the raw-range calculation already divided c times that time by two. A second factor of two is not justified. This reduced budget isolates one wet-path term; orbit, dry atmosphere, ionosphere and surface-response terms still matter in a complete altimetry product.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Carry units through a conditional conversion
Use a stipulated conversion k=0.0064 m per kg/m² for this exercise, so d=kW for column water vapour W. At W=20 kg/m², d=0.128 m. If the retrieval instead gives 22 kg/m² while the raw range is unchanged, the applied correction becomes 0.1408 m and the recovered height is 12.8 mm too high. The sign follows the declared positive-excess convention. Column mass per area and path length are different quantities linked here by an explicit model coefficient.
The paper gives approximately 6.4 mm of wet correction per kg/m² as a useful scale, while its derivation also involves atmospheric temperature. Our fixed k is a teaching assumption, not a universal atmospheric constant or a replacement for an operational correction. A small uncertainty in the column retrieval can matter when the intended signal is measured in millimetres. Treating a correction as exact because its formula is short hides the information and uncertainty used to estimate it.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Do not let an instrument step become a climate trend
Construct six annual surface-height anomalies at times 0, 1, 2, 3, 4 and 5 years. Let their true values be 0, 2, 4, 6, 8 and 10 mm, a trend of 2 mm/year. If a second instrument adds an 8 mm offset to the final three values, the combined record becomes 0, 2, 4, 14, 16 and 18 mm. A single ordinary least-squares line then has slope 142/35≈4.057 mm/year. This is an invented calibration-step example, not an observed Envisat sea-level trend.
Same-time, matched observations during an overlap can estimate a relative offset; removing an independently established 8 mm step restores the 2 mm/year slope. An equal hidden offset on both instruments would remain invisible to that comparison. The reviewed study also cautions against interpreting every difference from a changing background as instrument drift. Record compatibility requires more than joining files, and overfitting corrections to a reference can suppress the variation one hoped to measure. A credible long record keeps its measurement, calibration and comparison assumptions available for re-examination.
Correct the range and preserve the trend
Original sign and continuity examples. The wet delay is already expressed as one-way-equivalent range, so no second factor of two is applied. The plotted step is an invented instrument offset, not Envisat sea-level data; its effect on the fitted slope demonstrates why an independent overlap calibration matters.
Open full-size diagram in a new tab: Correct the range and preserve the trendCheck 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Bennartz et al.: intercalibrated ERS/Envisat water-vapour and wet-correction recordReviewed complete PDF pages 1–8 and 12–13; appendix pages visually inspected. The lesson uses a declared coefficient and original trend series rather than reproducing unresolved printed appendix formulas.
- Read: CNES AVISO+: Envisat Microwave RadiometerInstrument-specific channel, footprint and primary altimeter-correction context. Brightness temperatures are not independently resolved vertical profiles.
- Read: ESA: end of mission for EnvisatComplete end-of-mission announcement reviewed. Last contact, formal declaration and later use of preserved data remain distinct.