Lesson 4 of 4 · Reference targets and comparable radiometric measurements
Calibrate changing sensitivity
8 minute lesson · 3 checks along the way
Your goal for this lessonUse a reference-signal comparison to distinguish sensor response changes from changes in the observed scene.
In this lesson 3 sections · 3 checks
Read & understand
The same scene can produce a different signal
A sensor converts incoming light into recorded values. If its sensitivity changes, the same input can produce a different output. A lower recorded count therefore does not automatically prove that the observed surface became darker. Calibration estimates the relationship between the physical input and the instrument response.
In an invented linear sensor with zero offset, a fixed reference radiance first produces 100 counts and later 90. The response has fallen by ten counts, or 10 percent of the original response. This is a teaching example, not a reported FORMOSAT-5 calibration result. It holds the incoming radiance and other conditions constant to isolate sensitivity.
Hold the reference fixed to reveal response change
Original calibration model with explicit assumptions. Lin and colleagues’ historical FORMOSAT-5 measurements are not represented by these numbers.
Open full-size diagram in a new tab: Hold the reference fixed to reveal response changeCheck 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Bring a reference to the comparison
Tang-Huang Lin and colleagues studied FORMOSAT-5 RSI calibration using 2017–2018 observations. Their 2019 paper combines field measurements at Alkali Lake and Railroad Valley Playa with comparisons to Landsat-8’s Operational Land Imager. These provide ways to evaluate an orbiting sensor after launch.
A fair comparison must account for atmospheric conditions, viewing geometry and the instruments’ spectral responses. Two satellites looking at the same general landscape do not automatically receive equivalent signals. The field measurements and correction method help connect the reference with what the sensor actually observes.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Keep the calibration model and its dates attached
In the fictional zero-offset example, a later reading can be expressed on the earlier response scale by multiplying by 100/90, about 1.11. A later value of 45 then corresponds to 50 on that scale. This correction follows only from the stated linear model and reference conditions; it is not a calibration coefficient for RSI.
The published study concerns a particular historical interval. Its findings do not establish the instrument’s present response. An analyst should keep the band, calibration version, applicable dates and uncertainties with a product, then check whether those conditions match the observation being interpreted.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.