Lesson 3 of 3 · Error, bounds, alerts and service denominators
Distinguish accuracy from integrity
14 minute lesson · 3 checks along the way
Your goal for this lessonClassify a synthetic monitoring record using separate error, bound, alert and timing quantities, then calculate availability and continuity with explicit denominators.
In this lesson 4 sections · 3 checks
Read & understand
A small observed error is only one part of the question
Accuracy concerns how close an estimate is to the quantity being estimated. Integrity also concerns the trust that can be placed in the information and the ability to warn when required conditions are not met. Availability and continuity describe other aspects of a service. GAGAN combines correction and integrity information through a monitored augmentation chain; these concepts should not be collapsed into a single advertised accuracy number.
Build an original scalar monitoring exercise with an alert limit A = 10 metres and an allowed warning delay of four seconds. Let E be the nonnegative error magnitude determined afterward from independent truth, and P be a reported protection quantity in the fictional record. The receiver does not know E in real time simply because a textbook table lists it. For this exercise, a usable solution requires valid support, P < A and no active alert; equality P = A is unavailable. The thresholds and classification rules here are teaching assumptions, not actual GAGAN certification requirements or a procedure for choosing whether to fly.
Read & understand
Read the estimate and its protection information separately
For a valid, supported solution with E = 2 metres and P = 6 metres, the reported protection quantity lies below A and the offline error is also smaller. The synthetic record meets the stated conditions at that epoch. If E remains two metres but P rises to twelve, the protection quantity exceeds the allowed threshold. The modeled service is unavailable for this assumed requirement even though its actual error happened to be small. This does not, by itself, prove a measurement fault.
A missing position is another distinct case: there is no solution to classify as an accurate or inaccurate coordinate. If E = 7 metres while P = 5, the actual error exceeds the reported protection quantity even though both are below A. That is a failure of the stated bound to cover this observation; it is not the same event as error exceeding the alert limit. Preserve each comparison instead of calling every unusual row a generic bad signal.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Time the warning from the specified onset
Suppose a synthetic event begins at timestamp 100 seconds with E = 12 metres while P = 8 metres still indicates a quantity below the ten-metre threshold. The offline truth exceeds A, and the protection information understates it. A warning at 103 seconds arrives three seconds after the specified onset, within the fictional four-second allowance. Correct timing uses the event’s onset and the actual warning time on a common time reference.
If the E > A condition persists through timestamp 105 while the service is still declared usable and no warning has arrived, the allowance has been missed. A later warning does not retroactively become timely. Likewise, an event log that records only the eventual maximum error cannot reveal the time-to-alert without an onset definition and synchronized records. In a real assessment, integrity risk depends on specified event definitions, distributions and exposure; one classroom event or a percentage from a small table is not a certified risk estimate.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Choose denominators that match the service question
Imagine 1,000 planned evaluation epochs, with the complete stated service conditions met at 920. The exercise’s availability is 920/1,000 = 92 percent. The denominator includes the planned unavailable epochs; discarding them would inflate the result. Now take a different experiment: 100 observation windows were already available at their starts, and 96 continued without a service interruption throughout the defined window. Its empirical continuity fraction is 96/100 = 96 percent.
The two fractions answer different questions and cannot be substituted for each other. Window length, sampling, dependence and selection affect their interpretation; neither fixture establishes a real system’s long-term performance. Historical certification, receipt of a broadcast, a low error in one test and continuous supported service are separate claims. A useful technical comparison states the requirement, observes the relevant quantities, defines the event and denominator, and retains unavailable or missing results rather than hiding them inside an average.
A bound, a limit and a warning clock
E is available only from later independent truth. A declared bound above the chosen limit does not prove a measurement fault. Alert timing, missing solutions and the denominators for availability and continuity must be recorded separately.
Open full-size diagram in a new tab: A bound, a limit and a warning clockCheck 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: ESA Navipedia — IntegrityESA explanation of error, protection, alert limits and warning time. The course thresholds and small audit table are fictional and do not estimate certified integrity risk.
- Read: ESA Navipedia — SBAS FundamentalsESA educational overview distinguishes accuracy, integrity, continuity and availability. The course does not adopt a generic operational threshold or service guarantee.
- Read: Press Information Bureau — GAGAN: Navigating India’s Skies with PrecisionJuly 1, 2026 programme-level government account. Describes operational augmentation and payload hosts, not live health or universal accuracy at a particular location.