Lesson 3 of 4 · Exposure, event counts and uncertainty
Compare electronics event rates
8 minute lesson · 3 checks along the way
Your goal for this lessonNormalize original electronics event counts by observed device-hours without mistaking the result for radiation dose.
In this lesson 3 sections · 3 checks
Read & understand
Treat the stated experiment as a question
ANU describes an intended investigation of radiation effects on commercial off-the-shelf electronics, including single-event latchup. This course uses that purpose to motivate a simpler original exercise about counting events. It does not present invented counts as flight measurements or infer a specific device failure mechanism from a tally.
An event counter reports occurrences that meet its defined detection rule. To compare two counters, a reviewer needs the rule, observing duration, number of devices and relevant conditions. A count without those definitions can conceal differences in how long or how many devices were observed.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Normalize by the exposure that was observed
In a fictional test, two devices each contribute one hundred monitored hours, giving two hundred device-hours in total. Four recorded events correspond to 4 / 200 = 0.02 events per device-hour. Device-hours describe accumulated monitored exposure in this exercise; they are not units of absorbed radiation dose.
A second fictional test records six events across six hundred device-hours, or 0.01 events per device-hour. It has more total events but a lower observed rate. The calculation alone does not prove one device design is intrinsically safer: the detection rules and test environments may differ, and these small samples contain uncertainty.
Compare events with monitored exposure
These invented event rates are not radiation-dose measurements or GhanaSat-1 flight results.
Open full-size diagram in a new tab: Compare events with monitored exposureCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Keep missing observations out of the denominator
Suppose a fictional logger records events during eighty hours but has a twenty-hour gap. If the event count covers only the logged period, dividing it by one hundred hours would imply observation during the gap. Use the actual monitored exposure and state what is unknown. Missing records are not evidence of zero events.
For a successor experiment, preserve configuration, event definitions, monitored intervals and the underlying records. Those details let another team repeat the rate calculation and judge whether two tests are comparable. A precise-looking number without its denominator and conditions is a weak basis for a broad conclusion.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional