Lesson 1 of 3 · Measurement intervals and quality
A timestamp is not the whole measurement
16 minute lesson · 3 checks along the way
Your goal for this lessonUse valid exposure, interval definitions and quality information to combine records without inventing data in gaps.
In this lesson 6 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
A system needs more than one kind of evidence
A solar-wind record, an auroral image and a simulated magnetic field can describe connected events without measuring the same thing. Their clocks, locations, response times and units may differ. Putting the plots side by side is the beginning of a comparison, not its conclusion. This course develops the work between receiving a record and using it to test an explanation.
NASA’s Global Geospace Science program, GGS, combined Wind and Polar with ground investigations, theory and data handling. It was a US contribution within the broader International Solar-Terrestrial Physics effort, ISTP. The existing introductory lesson explains that architecture. Here we will work through measurement intervals, vector frames and model comparisons using explicitly fictional data.
Wind launched on November 1, 1994. Its early trajectory included magnetospheric orbits before an L1 Lissajous orbit in 2004 and a halo orbit in 2020. A launch photograph cannot establish where a later measurement was taken: use that measurement’s position record. Look at the launch photograph: the WIND label appears on the adjacent tower, not on the rocket.
Wind launches aboard a Delta II in November 1994. The photograph records the launch, not the spacecraft’s later location or the quality of a scientific data product.
Look closely
Can this launch photograph establish where a later field measurement was taken?
See what to notice
It documents the launch. A later observation needs its time-tagged position, instrument definition and quality information; the spacecraft’s name alone does not identify its sampling environment.
Read & understand
Choose the product before doing arithmetic
The historical GGS design distinguished rapid summary products from the data needed for detailed scientific work. Its early Key Parameters used preliminary orbit information and incomplete calibration. They helped investigators find interesting intervals; that did not make them a sound quantitative reference. This historical warning must not be applied indiscriminately to every modern product whose name contains “KP.” Read the actual product documentation.
A useful record includes more than a plotted number. Determine the measured quantity, units, coordinate frame, time support, processing version and quality information. Current ISTP metadata guidance describes dependencies between science variables and their time variables, along with units, missing-value markers and explanatory notes. Those descriptions help recover the meaning of a dataset; a common file format alone does not supply calibration.
For the following exercise, the quantity is magnetic-field magnitude in nanotesla, nT. Time is measured in seconds from an arbitrary origin. The declared usable range is 0–100 nT, quality code 0 means usable, and code 1 means calibration mode. These are rules for our invented table, not universal Wind or Polar flag definitions. The fill marker −10³¹ means missing. It is neither a very large physical field nor a zero measurement.
Read & understand
Weight the seconds that were actually measured
Consider four nonoverlapping records covering a 120-second window. The first reports a mean of 2 nT over [0,20) seconds; the second reports 8 nT over [20,80). The third, [80,100), contains the fill marker. The fourth, [100,120), contains 40 nT but carries calibration code 1. A bracket [a,b) includes the starting instant and excludes the ending one, so adjoining records do not count the same boundary twice.
Only the first two records are usable. Their valid exposure is 20 + 60 = 80 seconds. The integral represented by their means is 2 × 20 + 8 × 60 = 520 nT·s. Dividing by valid duration gives 520 / 80 = 6.5 nT. This is the mean over the valid observed time, with every valid second weighted equally.
The ordinary mean of the two record values is (2 + 8) / 2 = 5 nT. That weights a 20-second record as heavily as a 60-second record, answering a different question. Including the in-range 40 nT calibration value would produce 13.2 nT over 100 seconds. Its numerical plausibility does not cancel its quality flag. Selecting records is part of the scientific definition of the average.
Using complete interval means with their full durations does not require the signal to have been constant inside each interval. Each mean already summarizes its own integral. We will need an extra assumption when we ask for only part of one interval.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Keep a gap separate from a quiet interval
The valid coverage is 80 / 120 = 2/3, about 66.7%. Suppose this exercise declares in advance that a reported bin must have at least 75% valid coverage. This bin fails that rule. The threshold is our analysis choice, not a universal NASA standard. A different rule may be justified for another purpose, but it should be stated and the actual coverage retained.
Dividing 520 nT·s by all 120 seconds gives about 4.33 nT. That is what zero-filling the missing 40 seconds would imply. There is no observation supporting that substitution. A quiet interval is a valid measurement of a small quantity; a gap is an absence of usable evidence. The average of the whole window is not identified by the valid-exposure mean alone.
We can calculate conditional bounds if additional information is supplied. Suppose the unobserved field magnitude is known, for this hypothetical problem, to stay between 0 and 10 nT. Its missing integral lies between 0 and 400 nT·s. The full-window average then lies between 520 / 120 and 920 / 120: approximately 4.33–7.67 nT. Those are bounds from the stated assumption, not a statistical confidence interval or recovered measurements.
Report both the value and its scope: “6.5 nT across 80 valid seconds of a 120-second window.” This lets a reader distinguish what was measured, what was excluded and what remains unknown.
Weight the time you actually observed
Original diagram using fictional intervals. Timeline widths represent duration. Only the two usable records contribute to the 520 nT·s integral and 80-second denominator. Coverage uses the full 120-second window; the 75% rule is an exercise choice, not a universal mission standard.
Open full-size diagram in a new tab: Weight the time you actually observedCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
A partial bin needs more than a whole-record mean
Now ask for the mean over [10,70) seconds. If we explicitly approximate each usable record as constant within its interval, the new bin includes ten seconds at 2 nT and fifty at 8 nT. Its mean is (10 × 2 + 50 × 8) / 60 = 7 nT. Overlap duration supplies the weights. Using the original 20- and 60-second durations would answer the old question instead.
The constant approximation is doing real work. Another possible signal is 2 nT throughout [0,20), then 7 nT during [20,70) and 13 nT during [70,80). Its second whole-record mean is still (50 × 7 + 10 × 13) / 60 = 8 nT. It therefore produces exactly the same two usable records and the same 6.5 nT valid-exposure mean.
Yet its mean over [10,70) is (10 × 2 + 50 × 7) / 60 = 37/6, approximately 6.17 nT, rather than 7. The original interval means do not distinguish these possibilities. Partial-bin resampling requires finer data or an explicitly stated within-interval model. A smoothly drawn interpolated line does not make that model an observation.
This also limits claims about short peaks. A moderate interval mean can contain a brief, larger excursion. To investigate that excursion, seek an appropriate higher-resolution, calibrated product and retain its response and quality information.
Read & understand
Carry the meaning with the result
A time tag needs its convention. Our second usable record covers [20,80) seconds. If its tag is defined as the midpoint, the tag is 50 seconds, with 30 seconds of support on each side. Treating that tag as the beginning would move its apparent support to [50,110), mixing an observed interval with a gap. The same printed time can mean different things in different products.
ISTP guidance provides ways to describe a tag’s position within a measurement period and the offsets around it. Inspect those descriptions rather than assuming that all tags are midpoints, starts or ends. Preserve the time scale too: values that look like ordinary clock times can use different time representations. The simple relative-second table here avoids that conversion problem; it does not solve it for an archive file.
A reproducible comparison retains the product and version, variable definition, units, actual position, interval convention, excluded flags, weighting and coverage. Keep both original records and the analysis rule. GGS’s coordinated observations become more useful when another investigator can reconstruct how a number was obtained—and see which conclusions the missing intervals prevent.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: NASA: Global Geospace Science objectivesExplore how Wind, Polar, ground observations and theory were designed to work together. This historical overview describes the program’s objectives before launch.
- Read: The Global Geospace Science Program and its InvestigationsRead the program’s original scientific and data-handling design. Its discussion of preliminary Key Parameters describes that historical system, not every modern product with the same abbreviation.
- Read: NASA Wind project: mission and orbital historyFollow Wind’s launch and changing trajectory. A specific measurement still needs its own time-tagged position rather than a location inferred from the mission’s name.
- Read: ISTP Metadata Guidelines v1.0.0: VariablesLearn how science variables connect to time and other support variables in version 1.0.0 of the ISTP metadata guidelines.
- Read: ISTP Metadata Guidelines v1.0.0: Variable AttributesFind definitions for units, missing values and measurement-time support. Interpret these attributes alongside the particular product’s calibration and quality documentation.