Lesson 1 of 3 · Differential acceleration and rotational correction
Recover gravity from a rotating pair
24 minute lesson · 3 checks along the way
Your goal for this lessonRecover a gravity gradient from a rotating accelerometer pair and quantify leakage from unequal sensor gains.
In this lesson 4 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
Measure a difference inside a falling spacecraft
GOCE, the Gravity field and steady-state Ocean Circulation Explorer, studied Earth’s gravity from low orbit. Its six accelerometers formed three perpendicular pairs with half-metre baselines. GPS tracking complemented the gradient measurements, while ion propulsion counteracted drag. ESA describes a spacecraft whose instrument and control system worked together as one measuring device. This lesson examines one pair rather than attempting to reconstruct the complete flight processor.
Free fall does not make gravity disappear. The spacecraft and its proof masses share much of their gravitational acceleration, but gravity changes across their separation. The instrument measures the forces needed to keep the masses in their prescribed positions. Its readings also contain effects of spacecraft rotation and nongravitational acceleration. A difference can remove an identical common contribution; it cannot identify every remaining term as gravity.
Read & understand
Declare the axes and the sign before subtracting
Use an original rigid-body model. Two sensor locations lie at x=+L/2 and x=−L/2. The body rotates at constant angular speed ω about the perpendicular z axis. Let G=∂g_x/∂x be the locally constant gravitational gradient. Define a+ and a− as the signed acceleration supplied to hold each proof mass fixed relative to the body. With common nongravitational acceleration a_c, ideal gains and no other errors, a±=a_c+(−G−ω²)(±L/2). The rotation term is inward centripetal acceleration along x.
Form the full difference Δa=a+−a− and divide by L: D=Δa/L=−G−ω². Thus G=−D−ω². This is a force-readout convention, not a rule for every instrument’s raw telemetry signs. Gruber and Rummel define differential mode as the half-difference d=Δa/2, so their corresponding expression contains −2d/L. Mixing the full-difference and half-difference conventions introduces a factor-of-two error.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Recover a gradient and check the omitted term
Choose fictional inputs L=0.5 m, ω=0.001 rad/s, G=2.4×10⁻⁶ s⁻² and a_c=2×10⁻⁶ m/s². The readings are a+=1.15×10⁻⁶ and a−=2.85×10⁻⁶ m/s². Their mean recovers a_c. Their full difference is −1.70×10⁻⁶ m/s², giving D=−3.4×10⁻⁶ s⁻². Subtracting ω² from −D recovers G=2.4×10⁻⁶ s⁻².
Simply negating D would instead report 3.4×10⁻⁶ s⁻². The error is 1×10⁻⁶ s⁻², or 1000 Eötvös, where 1 E=10⁻⁹ s⁻². A real three-dimensional reduction also handles angular acceleration, attitude, calibration and unequal axis sensitivity. Star-tracker information helps constrain rotation; these fictional numbers are neither achieved GOCE precision nor a substitute for that reduction.
Separate rotation from the acceleration difference
Original simplified holding-force convention. Rotation about z is constant, and G is the local x-directed gravity gradient. Sensor spacing is schematic; numbers are not measured mission performance.
Open full-size diagram in a new tab: Separate rotation from the acceleration differenceCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Test whether common acceleration really cancels
Now let the two measured gains be 1+ε and 1−ε, so m+=(1+ε)a+ and m−=(1−ε)a−. Expanding the measured difference gives (m+−m−)/L=D+2εa_c/L. Applying the ideal correction to these mismatched readings biases the estimated gradient by −2εa_c/L. Common acceleration has leaked into the difference because the two channels no longer respond equally.
For ε=0.0001 and the same L and a_c, the bias is −8×10⁻¹⁰ s⁻², or −0.8 E. Reducing a_c tenfold reduces this particular bias to −0.08 E; it does not repair the gain mismatch itself. This explains why drag control and calibration reinforce each other. The annotated photograph shows reflected light from GOCE crossing a starfield, not the gradients or the accelerometer geometry.
Marco Langbroek’s annotated long-exposure observation of GOCE over Leiden on 3 January 2010, including the source’s inset and labels. Commons’ 2013 revision adjusts brightness and contrast (RicHard-59). Reflected light marks the track; it does not show gravity data or spacecraft geometry. Complete deposited frame retained; WebP conversion for display.
Look closely
What does the annotated track establish, and what can it not reveal?
See what to notice
It records reflected light from the identified spacecraft across a starfield. The inset and labels belong to the source image. It supplies neither the gradiometer baseline geometry nor measurements of Earth’s gravity.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: ESA: GOCE’s payloadOfficial paired-sensor geometry, GPS tracking and drag-control arrangement. No advertised sensitivity is used as a guaranteed accuracy.
- Read: Gruber and Rummel: Concept and Capability of GOCEHistorical technical concept, substantive printed pages 31–37; especially the force model, half-difference definition and diagonal-gradient correction. Design predictions and planned launch date are not flight results.