Lesson 2 of 3 · Profiles and averaging kernels
SHOW: compare the same vertical detail
12 minute lesson · 3 checks along the way
Your goal for this lessonMatch the vertical sensitivity of two profiles before treating their differences as an instrument bias.
In this lesson 4 sections · 3 checks
Read & understand
A profile is not a stack of perfect point samples
SHOW, Spatial Heterodyne Observations of Water, investigates water vapour using limb-scattered light. The instrument team reported aircraft demonstration measurements from July 2017 and compared retrieved profiles with radiosonde observations. Those observations support the measurement concept; they are not a HAWC satellite dataset. A particularly useful part of that comparison is the treatment of vertical resolution: a finely sampled reference must be brought to a compatible scale before the profiles are judged.
An instrument can report a value at a named altitude while remaining sensitive to air above and below it. In an elementary linear model, that reported value is a weighted average of nearby true values. The weights describe the model’s vertical sensitivity. Actual retrieval averaging kernels can be more complicated, and sample spacing alone does not specify resolution. This lesson uses simple, nonnegative weights adding to one so the distinction can be calculated without a full atmospheric retrieval.
Read & understand
Apply the same smoothing to the reference
Take three reference layers with water-vapour mixing ratios of 2, 10 and 2 parts per million by volume. Our modeled middle-level retrieval uses weights 0.25, 0.50 and 0.25. It therefore predicts 0.25 × 2 + 0.50 × 10 + 0.25 × 2 = 6 ppmv. A reported middle value of 6 agrees exactly with that prediction. Comparing it only with the central reference value of 10 would suggest a four-ppmv deficit that the smoothing already explains.
This calculation does not erase the narrow wet layer. It asks what the coarser observation should measure if that layer is present. Keep both the fine reference and the matched-resolution result. If a second instrument uses weights 0.10, 0.80 and 0.10, it predicts 8.4 ppmv for the same atmosphere. The two instruments can therefore return 6 and 8.4 without either being biased in this model. They are sensitive to different vertical detail.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Test residuals against a stated comparison
Now suppose the first instrument reports 6.6 rather than 6. Its matched-reference residual is +0.6 ppmv. Relative to the matched reference, the difference is 0.6/6 = 10 percent. Relative to the unsmoothed central peak it would look like −34 percent, answering a different and unsuitable comparison. State the denominator, the direction of subtraction and the smoothing method whenever a percentage difference is reported.
A single residual does not establish a persistent calibration bias. Repeated paired measurements can reveal whether the discrepancy is systematic or varies with altitude, temperature, clouds or pointing. Before combining pairs, check time and location. A radiosonde drifting through changing air and a long limb path need not sample exactly the same atmosphere. Matching a vertical filter addresses one difference in sensitivity; it does not remove all spatial or temporal mismatch.
Compare profiles at the same resolution
Original nonnegative averaging weights, not a SHOW retrieval kernel. Real validation also needs suitable time, location, geometry and uncertainty.
Open full-size diagram in a new tab: Compare profiles at the same resolutionCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Do not recover detail that was never measured
The 6-ppmv average is also consistent with a flat profile of 6, 6 and 6 under these weights. One averaged number cannot determine three independent layer values. Recovering a detailed profile requires more independent measurements and assumptions about which profiles are plausible. Adding more output rows by interpolation does not supply those missing observations. A smooth-looking graph may describe a representation choice rather than improved atmospheric resolution.
For HAWC, complementary observations can help constrain atmospheric interpretation, provided their sensitivities and sampling are carried through the comparison. Write a compact evidence statement: the measured value, the reference transformed to matching sensitivity, the residual, and the remaining sources of mismatch. The SHOW aircraft study is an example of evaluating a technique against another measurement rather than assuming that a prototype’s apparent detail proves accuracy. Our exact three-layer values are teaching models, not reported SHOW results.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Langille and colleagues: SHOW airborne demonstration2017 aircraft observations reported in 2019, including comparison with radiosonde profiles after matching vertical resolution.
- Read: CSA: HAWC, September 2026 mission revisionCurrent development scope and the three complementary instruments. The 2032 date is a plan, not a completed launch.