Lesson 2 of 3 · Helios directional temperature
Temperature needs a direction
16 minute lesson · 3 checks along the way
Your goal for this lessonProject a gyrotropic core temperature along a measurement direction, recover two components when possible and distinguish scalar temperature from one projection.
In this lesson 6 sections · 3 checks
Read & understand
Subtract the flow before describing random motion
A solar-wind proton population streams away from the Sun, but individual particles do not all have the same velocity. Temperature describes the random part of their motion after the population’s bulk velocity has been removed. For one velocity component, temperature is proportional to the corresponding variance, with particle mass and Boltzmann’s constant supplying the conversion. A change in the bulk speed is therefore not automatically a change in temperature. Choosing the core or the full proton population also matters, as the preceding mixture calculation showed.
The magnetic field supplies a physically useful direction. A gyrotropic distribution is rotationally symmetric about that direction: it has one temperature parallel to the field, T∥, and equal temperatures T⊥ along two mutually perpendicular directions across the field. Gyrotropy does not require T∥ and T⊥ to be equal. We will hold a fictional proton core fixed at T∥ = 80,000 K and T⊥ = 240,000 K. These are teaching values chosen to make directional effects visible, not temperatures assigned to a particular Helios encounter.
Read & understand
Project the same distribution into a radial direction
Let θ be the angle between the magnetic field and the radial measurement direction, pointing away from the Sun. For this unchanged gyrotropic core, the radial temperature is Tᵣ = T∥ cos²θ + T⊥ sin²θ. Squared direction cosines enter because this is a second moment of velocity. At θ = 0°, the radial direction lies along the field and gives 80,000 K. At 90°, it lies across the field and gives 240,000 K. Both describe the same distribution.
At 60°, cos²θ = 1/4 and sin²θ = 3/4, so Tᵣ = 80,000/4 + 3 × 240,000/4 = 200,000 K. At 30°, the weights reverse and the answer is 120,000 K. A plot of radial temperature can consequently rise as the field rotates even if the field-aligned temperatures stay fixed. Real observations may also contain evolving plasma, so a changing angle does not prove that rotation explains every change. It does show why a single projected temperature cannot by itself establish heating.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Use three components for a scalar temperature
The scalar temperature averages the three orthogonal components: T = (T∥ + 2T⊥)/3. The factor of two counts two perpendicular directions, not two separate proton populations. Our fixed core therefore has scalar temperature (80,000 + 480,000)/3 ≈ 186,667 K. Averaging only the two distinct labels would give 160,000 K and underweight perpendicular motion. The radial projection at 60° is 200,000 K, which is also a valid quantity but is not this scalar average.
In matrix language, three times the scalar temperature is the trace of the temperature tensor. Rotating coordinates preserves that trace, even though its individual components can change. This gives a useful consistency check for a calculation: a mere rotation of an unchanged distribution must not alter the scalar temperature. It does not remove the need to select the same particles and subtract the correct bulk velocity. Changing from a total proton moment to a core fit, or using a different calibration, can change the tensor itself rather than just its coordinate description.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Recover two temperatures only from independent information
Suppose two ideal projections of the same unchanged gyrotropic core are 120,000 K at 30° and 200,000 K at 60°. They give 0.75T∥ + 0.25T⊥ = 120,000 and 0.25T∥ + 0.75T⊥ = 200,000. Adding gives T∥ + T⊥ = 320,000 K; subtracting gives T⊥ − T∥ = 160,000 K. Thus T∥ = 80,000 K and T⊥ = 240,000 K. Each equation contributes information the other lacks.
Two different-looking angles need not supply two independent equations. Angles 30° and 150° have the same cos² and sin², so they produce identical weights. They cannot recover both unknown temperatures. Nearly identical weights also make an inversion sensitive to measurement errors. Furthermore, measurements at different times cannot be combined this way unless the unchanged-distribution assumption is justified. This exercise illustrates identifiability; it is not a replacement for the Helios distribution-fitting procedure, which uses sampled velocity-space information and magnetic-field measurements.
One core, several projected temperatures
Original fixed-core model, with Tᵣ = T∥ cos²θ + T⊥ sin²θ and scalar T = (T∥ + 2T⊥)/3. Field rotation changes a projection without changing the trace. The two-equation inversion requires independent squared-angle weights and an unchanged distribution; it does not implement the full Helios fitting procedure.
Open full-size diagram in a new tab: One core, several projected temperaturesCheck 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Choose quality flags for the variable you need
The September 14, 2017 corefit guide makes quality parameter-specific. In that dated scheme, status 1 supports velocity, density and temperature. Status 2 retains usable velocity but flags magnetic-field variation, making density and temperature unreliable. Status 3 retains velocity when magnetic-field information is unavailable, without usable density or temperature. Status 4 marks a failed fit. These definitions belong to the named guide; always read the documentation accompanying a different release instead of assuming that every numbered status means the same thing.
For a fictional sequence with statuses 1, 2, 1, 3, 4, 1, suppose the three status-1 temperatures are 100,000, 200,000 and 300,000 K. The eligible temperature mean is 200,000 K from three values. Five records still have usable velocity under this scheme. Averaging the temperatures over all six timestamps would silently turn three missing values into zero and give 100,000 K. Keeping all successful velocity fits as temperature samples would make a different mistake: treating a parameter-specific success as permission to use every parameter.
Read & understand
A field direction is also a measurement
The projection equation assumes that the magnetic-field direction is known for the relevant distribution. A field that changes appreciably during sampling can undermine a simple fixed-axis fit. Missing or inconsistently calibrated magnetic data can also affect the interpretation. The E1 archive’s later E2/E3 magnetic-data note is a reason to identify the input magnetic product and processing version, not permission to invent a correction from these teaching numbers. A quality flag should accompany the value rather than disappear when it is copied into a plot.
When two temperature records disagree, first compare population, direction, time window, units, processing and eligibility. Then ask whether the remaining difference supports physical evolution. The three numbers 80,000, 200,000 and about 186,667 K can all correctly describe different aspects of our one unchanged core: its parallel component, its 60° radial projection and its scalar temperature. A defensible comparison names which quantity it uses. In the final lesson, even correctly defined and eligible measurements need another check: whether samples at different distances represent comparable solar-wind streams.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Stansby et al.: A New Inner Heliosphere Proton Parameter DatasetStudy how the 2018 reprocessing separates the proton core from total moments and uses field-aligned temperature information.
- Read: Helios corefit data product user guide, September 14, 2017Use the explicitly dated September 2017 guide for parameter definitions, status flags, temperature conventions and timestamp limitations.
- Read: Helios Data Archive: E1 Plasma DetectorsFind the preserved experiment records and reanalysis notes, including magnetic-input calibration concerns. Check physical units and definitions against the instrument papers and release guide.