Lesson 2 of 3 · Moving-interface conservation
Conservation uses the boundary frame
16 minute lesson · 3 checks along the way
Your goal for this lessonSolve a moving-interface particle balance, keep reference frames consistent and recognize unstable or insufficient inferences.
In this lesson 6 sections · 3 checks
Read & understand
Count particles through a moving interface
A plasma boundary can have different densities on its two sides without creating or destroying particles. To see how, define upstream as the side from which the flow approaches the interface and downstream as the side it leaves. In this fictional one-dimensional example, both flows point along our chosen positive normal axis. That axis is a sign convention, not an assertion that every space-plasma normal points in the same physical direction.
Let n_u and n_d be proton number densities, v_u and v_d the signed normal flow velocities in a common reference frame, and U the signed boundary speed in that frame. We assume a planar interface that is steady in its own frame, only protons, constant particle mass and no particle sources or losses. Under those assumptions, conserving proton number also conserves proton mass.
An instrument reports flow relative to a stated frame. To count particles overtaking the boundary, subtract its speed: upstream relative velocity is v_u − U, and downstream relative velocity is v_d − U. This subtraction is about the interface, even if no spacecraft is sitting on it.
Read & understand
Solve the relative number balance
Number flux is density multiplied by the normal velocity relative to the surface being crossed. For the steady boundary, the entering and leaving values must agree: n_u(v_u − U) = n_d(v_d − U). The equality says that the interface does not continually accumulate particles in this model.
Expand both sides and collect the terms containing U. Provided n_d differs from n_u, the solution is U = (n_d v_d − n_u v_u) / (n_d − n_u). A larger density is balanced by a smaller relative velocity when the flow keeps the same sign. The equation does not say that density multiplied by reference-frame velocity must be identical on both sides.
Take n_u = 5 cm⁻³, n_d = 20 cm⁻³, v_u = 100 km/s and v_d = 40 km/s. The numerator is 20 × 40 − 5 × 100 = 300 in mixed density–velocity units; the density difference is 15 cm⁻³. Their ratio is U = 20 km/s. These numbers define a fictional continuity example, not a fitted ISEE shock.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Check the answer and its units
In the boundary frame, the two velocities are 100 − 20 = 80 km/s and 40 − 20 = 20 km/s. Their number fluxes are 5 × 80 = 400 and 20 × 20 = 400 cm⁻³ km/s. Density has increased by a factor of four while relative velocity has decreased by four. The equal products provide a useful check on the inverse solution.
For a flux per square centimeter per second, convert kilometers to centimeters. One kilometer is 100,000 cm, so 400 cm⁻³ km/s equals 4 × 10⁷ protons cm⁻² s⁻¹. This is number flux. A mass flux would also include the proton mass with compatible units; an energy flux needs further information about the particle population.
The reference-frame products are instead 5 × 100 = 500 and 20 × 40 = 800 cm⁻³ km/s. Their inequality is not automatically a continuity failure. They describe transport through surfaces fixed in that reference frame. The boundary moves across those fixed surfaces, changing which density occupies a fixed volume.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Verify it with a fixed column
Consider a thin imaginary column extending from x = −100 km to x = +100 km, with cross-sectional area 1 cm². At time zero the interface lies at x = 0, with upstream density 5 cm⁻³ to the left and downstream density 20 cm⁻³ to the right. Each 100-km half is 10 million centimeters long, so the column initially contains 50 million + 200 million = 250 million protons.
After one second the interface has moved 20 km to the right. The low-density region occupies 120 km of the column and the high-density region 80 km. The particle count becomes 60 million + 160 million = 220 million. The column has lost 30 million protons even though the moving boundary itself obeys the relative balance.
That loss equals the fixed-end flux difference: 50 million protons enter through the left end each second, while 80 million leave through the right. There is no hidden particle sink. The changing proportions of the two regions account for the accumulation term. Checking a finite volume makes clear why a stationary-interface equation cannot simply be applied to a moving interface.
The moving boundary changes the velocity
Original fictional proton-only continuity example. All arrows point along the chosen positive normal; plasma velocity arrows use 2 pixels per km/s. The column bars use 2.4 pixels per km. Flux equality is a boundary-frame statement; the fixed column can lose particles without a particle sink at the moving interface. This is not a full shock solution.
Open full-size diagram in a new tab: The moving boundary changes the velocityRead & understand
Change frames, then test sensitivity
Now describe the same event from a frame moving at +50 km/s along the chosen normal. Subtract 50 from every reference-frame velocity: v_u becomes 50, v_d becomes −10, and U becomes −30 km/s. The relative velocities remain 50 − (−30) = 80 and −10 − (−30) = 20 km/s. The conserved number flux is unchanged. A negative boundary speed in this new frame is not a reversal of the physical event.
The inverse calculation can nevertheless be fragile. For another fictional interface, let n_u = 5, n_d = 5.1 cm⁻³ and v_u = 100 km/s. If v_d = 99 km/s, the formula gives U = 49 km/s. Changing only v_d to 98.8 gives 38.8 km/s; changing it to 99.2 gives 59.2 km/s. A 0.2-km/s velocity change produces a 10.2-km/s boundary-speed change because the density difference is only 0.1.
If the densities are exactly equal and the normal velocities differ, no U satisfies this simplified steady balance. If both density and velocity are equal, every U cancels from the equality: continuity alone cannot determine its speed. These cases call for checking the model and seeking other evidence, not dividing by zero or quietly choosing a convenient speed.
Read & understand
A balance is one test of a shock
A successful particle balance is valuable, but it does not establish that the interface is a shock. A full physical classification also needs the appropriate momentum, energy and electromagnetic conditions, together with the behavior that distinguishes an irreversible shock from other discontinuities. Our calculation intentionally solves only the particle-continuity part of that larger problem.
The Viñas–Scudder report develops a much fuller shock analysis and compares estimates for an ISEE crossing. This course does not reproduce that iterative solution. Its simpler example lets you inspect the frame transformation and understand why one apparently convincing equality is not enough evidence for the entire classification.
An independent timing estimate can help. Before comparing it with the continuity estimate, give both the same normal convention and reference frame. A timing result of 20 km/s relative to spacecraft moving at 4 km/s along the normal corresponds to 24 km/s in the reference frame. Comparing 20 directly with a reference-frame result would manufacture a disagreement. Agreement after conversion remains conditional on both methods having sampled the same steady structure.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Shock and Discontinuity Normals, Mach Numbers, and Related ParametersChapter 10, printed pages 249, 251, 256–257 and 264: frame changes, timing geometry and mass flux. Our known-normal proton model is a limited teaching example.
- Read: Fast and optimal solution to the Rankine–Hugoniot problemNASA TM-86214, 1985: see printed pages 1–2 and 45 for shock-analysis scope and a timing comparison using an independently determined normal.