Lesson 2 of 4 · Shared continuum uncertainty
Keep the continuum error shared
23 minute lesson · 3 checks along the way
Your goal for this lessonPropagate uncertainty from one common continuum estimate without treating that error as independent in every normalized bin.
In this lesson 3 sections · 3 checks
Read & understand
Separate the sources of uncertainty
Return to the five-bin spectrum and C=10. Suppose each line-bin flux density has independent variance 1 in squared flux-density units. Estimate the continuum by averaging two independent external sideband measurements, each also with variance 1. Their average has variance 1/2. These sideband measurements are separate from all five line-window bins, including the two bins whose mean flux happens to equal the continuum.
That separation is essential to the example. We assume the line measurements and continuum estimate are independent before normalization. If a continuum fit reused the line-window measurements, or preprocessing correlated their errors, the covariance calculation would need those additional terms. No fictional unit variance here represents the actual noise of an IUE camera or establishes how its noise changes with exposure time.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Propagate the common reference once
Since every width is 1 Å, the integrated flux S has variance 5 in squared integrated-flux units. Near the mean values, a small change gives δW≈−δS/C+(S/C²)δC. The two independent inputs therefore contribute Var(W)≈Var(S)/C²+(S/C²)²Var(C). With S=42 and C=10, the line-flux term is 1/20 Ų and the common-continuum term is 441/5000 Ų.
The total is 691/5000 Ų, or 0.1382 Ų. This is a first-order variance around the stated means. It is not an exact distribution for a noisy ratio, and it is not a claim that a particular confidence interval or detection significance has been established. An exact treatment would also specify and propagate the joint probability distribution through the nonlinear division.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Find the missing cross terms
An incorrect shortcut gives each normalized bin its own independent copy of the continuum error. It sums (ΔλᵢFᵢ/C²)²Var(C) instead of first summing the coefficients of the single common δC. That produces a total of 341/5000 Ų, or 0.0682 Ų. The missing covariance terms contribute 7/100 Ų. Splitting one reference into imaginary independent references understates the uncertainty in this example.
We can check the linearized result independently. Assign each of the five line noises and two sideband noises either +1 or −1 with equal probability and independence. There are 128 equally likely combinations. Compute δC as the average of the two sideband noises, then evaluate the linearized δW for each combination. Its mean is zero and its exact mean square is 691/5000 Ų. This verifies the linearized calculation, not the exact nonlinear ratio variance.
One reference, shared uncertainty
Bar lengths use3500pixels per Ų. Each line bin has variance1; C is the average of two independent external sidebands with variance1 each. This is variance of the first-order error, not an exact noisy-ratio distribution.
Open full-size diagram in a new tab: One reference, shared uncertaintyRead diagram data as a table
| Treatment | Line term (Ų) | Continuum term (Ų) | Total first-order variance (Ų) |
|---|---|---|---|
| Shared continuum | 1/20 | 441/5000 | 691/5000 |
| Mistaken independent copies | 1/20 | 91/5000 | 341/5000 |
Bar lengths use3500pixels per Ų. Each line bin has variance1; C is the average of two independent external sidebands with variance1 each. This is variance of the first-order error, not an exact noisy-ratio distribution.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: SDSS: Line index measurement in SSPPContinuum estimation and wavelength integration matter for line indices. Explicit comparison context only; do not transfer the optical survey pipeline, thresholds or masks to IUE.
- Read: MAST: IUE data productsNEWSIPS versus IUESIPS provenance; MXLO/MXHI include calibrated flux, wavelength, flags and uncertainty-related arrays. Image products retain diagnostic context.