Lesson 2 of 3 · Electrolysis and system boundaries
Account for charge, oxygen and energy
20 minute lesson · 3 checks along the way
Your goal for this lessonCompute oxygen production from charge and cell count, then close mass and electrical-energy balances without confusing purity with efficiency.
In this lesson 4 sections · 3 checks
Read & understand
Separate the demonstration from the teaching device
MOXIE tested oxygen production from the Martian atmosphere aboard Perseverance. NASA reported that its operations ended after sixteen runs in 2023, with 122 grams produced in total. The instrument team describes intake compression, heating and solid-oxide electrolysis, followed by measurement of oxygen quantity and purity before release. That sequence matters because producing oxygen inside an electrochemical cell and delivering a useful resource through a complete system are different accounting boundaries.
The actual instrument used ten electrolysis cells, electrically arranged with a center tap so two five-cell halves could be controlled. Our numerical device instead has four identical cells in series. Assume sufficient carbon dioxide feed, fixed current through every cell, constant cell voltage and a stated useful-charge fraction. Ignore changing temperature, gas storage, leakage and side reactions except for charge that does not contribute to the specified oxygen yield. These invented inputs isolate the bookkeeping; they do not reproduce a MOXIE run or define safe operating settings.
Read & understand
Turn charge into a mass balance
The desired net reaction is 2CO2 → 2CO + O2. Producing one O2 molecule corresponds to transferring four electrons. With Faraday’s constant F = 96485 coulombs per mole of electrons, oxygen amount in moles is ηNIt/(4F), where N is productive series-cell count and η is the useful-charge fraction. Current I has units coulombs per second and t must be in seconds. Multiplying by 32 grams per mole converts oxygen amount into mass; it is not already a mass merely because current was measured.
For N = 4, I = 2 amperes, t = 1800 seconds and η = 0.90, the predicted oxygen mass is 1.074571 grams. Every cell contributes oxygen, even though the series current is the same throughout. Using rounded molar masses of 44 for CO2 and 28 for CO, the desired reaction consumes 88/32 times that oxygen mass as CO2 and forms 56/32 times it as CO. The results are 2.955071 grams consumed and 1.880500 grams formed; 1.074571 + 1.880500 closes the consumed-mass balance.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Include the energy needed around the reaction
At 1.4 volts per cell, the four-cell stack needs 5.6 volts. At 2 amperes, its electrical power is 11.2 watts. Stipulate another 188.8 watts for heating and auxiliaries during the production interval, making total input 200 watts. A half-hour run consumes 100 watt-hours. Dividing by 1.074571 grams gives approximately 93.06 watt-hours per gram. This calculation uses all specified production-stage electricity rather than counting only the charge-transfer hardware.
If warmup consumes an additional 40 watt-hours without producing oxygen, the full cycle requires 140 watt-hours, or about 130.28 watt-hours per gram. Omitting warmup answers a different question. Neither number is a thermodynamic efficiency: that would also require a defined useful-energy reference and appropriate treatment of heat. Likewise, the consumed CO2 mass is not the total atmospheric intake; unreacted feed and other gases can pass through a real instrument without becoming oxygen.
Follow charge, then close the system boundary
Original four-cell accounting model, not an actual MOXIE run. Series-cell oxygen production, reaction mass and full-cycle electrical energy use explicitly different denominators.
Open full-size diagram in a new tab: Follow charge, then close the system boundaryCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Keep yield, purity and scaling separate
Our 90 percent useful-charge fraction compares oxygen output with the amount predicted from transferred charge. A separate hypothetical outlet measurement of 98 percent oxygen by mole compares oxygen molecules with all molecules in that outlet stream. A pure product can be obtained at a low rate or with substantial energy overhead. Therefore, the purity percentage cannot replace η in the charge equation, and it cannot be described as the percentage of electrical energy converted usefully.
Adding identical series cells at fixed current and cell voltage multiplies both oxygen rate and stack power by the cell-count ratio. It does not provide free production from the same electrical power. Whole-system energy per gram can still change because heaters and auxiliaries need not scale identically. Actual MOXIE operation also faced temperature, voltage and carbon-deposition constraints that the toy model omits. A successful mass balance is a necessary consistency check, not evidence that an imagined larger plant would operate reliably.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: NASA’s Oxygen-Generating Experiment MOXIE Completes Mars Mission16th and final run on August 7, 2023; total 122 g; oxygen quantity and purity measured; operations concluded. Historical total, not ongoing output. Peak 12 g/h and ≥98% purity are achieved reported results, not inputs to classroom models.
- Read: Mars Oxygen ISRU Experiment (MOXIE)—Preparing for human Mars explorationAtmosphere compression, heating and solid-oxide electrolysis; oxygen measured then released. Ten series cells with center tap; controls can treat two five-cell halves. Power, temperature and coking constraints matter. Paper reports 2021 runs and future plans then; not current status. CC BY-NC article is linked and briefly paraphrased; no figure copied.
- Read: Mars Oxygen ISRU Experiment (MOXIE)Four electrons per O₂; oxygen molar rate proportional to number of series cells and current; stoichiometric CO/O₂ ratio. Eq 1-14 is described as mass flow but nI/(4 F) dimensionally gives mol/s with F in C/mol; lesson explicitly multiplies by 32 g/mol. Full DOI web inaccessible; primary author manuscript successfully downloaded.