Lesson 2 of 4 · Convert calibrated pulse power into heating energy and keep thermal evidence distinct from chemical identification.
Turn heater telemetry into energy
8 minute lesson · 3 checks along the way
Your goal for this lessonConvert calibrated pulse power into heating energy and keep thermal evidence distinct from chemical identification.
In this lesson 3 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
Heating and gas measurements answer different questions
Phoenix’s TEGA heated samples along a programmed temperature ramp while measuring the electrical power required. Its evolved-gas analyzer examined gases released during heating and related their signals to oven temperature. Heating behavior and gas signals are complementary: a thermal feature is not, by itself, an unambiguous name for a mineral or evidence of biology.
The calibration report explains an easily missed detail: the instrument combined digital voltage, current and pulse-width readings for downlink before converting them to physical units. Ground processing applied the appropriate gains and offsets. Electronics temperature also affected calibration. A field labeled power in raw telemetry therefore cannot simply be read as watts.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Calculate one simplified constant-pulse example
Use a fictional heater with constant readings throughout a 40-second interval. Let calibrated voltage equal 0.002 × (raw voltage − 200) volts and calibrated current equal 0.001 × (raw current − 100) amperes. Raw values of 1,200 and 500 give 2 volts and 0.4 amperes. Power while the heater is on is 2 × 0.4 = 0.8 watts. If it is on for 25% of the interval, average power is 0.2 watts.
Energy is average power multiplied by elapsed time: 0.2 × 40 = 8 joules. Suppose a matched reference run for the same interval requires 6 joules; the difference is 2 joules. This toy calculation assumes fixed readings, valid coefficients and no additional correction terms. Real TEGA reduction uses the recorded pulse-weighted sums and instrument calibration; multiplying average uncalibrated readings is not an equivalent shortcut.
Include the time the heater is on
Original worked example using fictional quantities and the assumptions stated in the lesson.
Open full-size diagram in a new tab: Include the time the heater is onCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Compare like conditions before naming a process
A difference in heating demand can be investigated alongside the temperatures and gases involved. Before comparing two runs, check the heating schedule, sample amount, cell behavior, thermal losses and calibration conditions. A larger energy difference could reflect more material or a different thermal environment. It does not uniquely determine a composition.
Keep the evidence layers visible: a delivery record identifies the material admitted, calibrated telemetry establishes the heating history, and gas analysis supplies additional chemical constraints. The sample may contain a mixture, and several processes may overlap during heating. Report which observations support an interpretation and which alternatives remain possible instead of turning a single peak into a complete history of the site.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: PDS: Phoenix TEGA reduced-data interface specificationVersion 2.1, October 8, 2008: printed pages 2–6 describe delivery verification, single-use cells, programmed heating and evolved-gas measurements. Historical PDS3 product documentation.
- Read: PDS: TEGA calibration reportVersion 1.20, April 22, 2009: printed pages 22–23 explain ground conversion of pulse-weighted telemetry to true power, including gains and offsets. The lesson uses a simplified fictional constant-pulse calculation.