Lesson 3 of 3 · Infrared spectra
Sample an infrared interferogram
10 minute lesson · 3 checks along the way
Your goal for this lessonRelate optical path difference to spectral wavenumber and demonstrate when distinct ideal signals have identical samples.
In this lesson 5 sections · 3 checks
Read & understand
Measure interference before interpreting the atmosphere
IKFS-2 is an infrared Fourier spectrometer used in the Meteor-M program. A 2013 instrument-calibration paper describes converting its measured interferograms into spectra with controlled radiometric and spectral accuracy. Its abstract also identifies detector nonlinearity and onboard reference-source characterization as calibration concerns. Spectral processing is therefore part of the measurement, not a decorative color treatment applied to a finished temperature profile.
An interferometer combines light that has traveled along different optical paths. Changing the optical path difference changes the interference signal recorded at the detector. Many spectral components contribute different oscillations; a Fourier transform separates their contributions under the measurement model. The resulting spectrum still needs a physical interpretation to infer an atmospheric state. The image of Europe used earlier is not an interferogram or a substitute for that spectrum.
Read & understand
Keep wavelength, path and phase in compatible units
Let σ denote wavenumber in inverse centimeters and δ the optical path difference in centimeters. For a single ideal spectral component, define the normalized varying part of the signal as c(δ) = cos(2πσδ). This is an original classroom model with zero initial phase. The detector’s positive background and real instrument effects are omitted. Negative c values describe variation around the background, not negative received power.
Wavelength in micrometers is λ = 10,000/σ. Thus σ = 1000 cm⁻¹ corresponds to 10 μm and σ = 1250 cm⁻¹ to 8 μm. For the 1000-cm⁻¹ component, an optical path change of 0.001 cm gives one full oscillation.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Distinguish mirror movement from optical path
In a simple moving-mirror Michelson arrangement, light travels to the mirror and back, so a 5-μm mirror displacement changes the optical path by 10 μm. That factor of two belongs to the stated geometry, not to an arbitrary spacecraft distance.
For the same ten-micrometer wavelength, moving that mirror ten micrometers changes the path by twenty micrometers: two complete cycles. Always identify which distance a number describes before using it in the phase equation. The model tracks an internal optical path, not the satellite’s orbital motion or the distance between the spacecraft and a cloud.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Show how different spectra can share the same samples
Sample the ideal signal at δn = n × 0.00025 cm for integer n. At σ = 1000 cm⁻¹, the first four samples, starting at n = 0, are 1, 0, −1, 0. At σ = 3000 cm⁻¹, they are also 1, 0, −1, 0. The curves between the samples differ, but all integer-indexed samples agree: the second phase advances by 3π/2 per step instead of π/2, and the cosine symmetry hides the difference.
This is sampling ambiguity, often called aliasing. Collecting more points at exactly the same path increment does not distinguish these two ideal components. At δ = 0.000125 cm, however, their values are approximately +0.707 and −0.707. A smaller increment can supply information the first sequence missed. The two candidate wavenumbers and increments are invented; they are not the IKFS-2 acquisition scheme or a claimed defect in the instrument.
Same samples, different spectral components
Original ideal cosine model. The wavenumbers and path increments are not the IKFS-2 sampling scheme; negative values describe the varying signal component.
Open full-size diagram in a new tab: Same samples, different spectral componentsCheck 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Sampling and spectral resolution answer different questions
A known admitted spectral band and appropriate sampling prevent unwanted components from masquerading as other ones. The extent of the measured path interval also matters: distinguishing closely spaced components requires enough information about their differing oscillations. Finer sampling and a longer measured interval address different limits. Adding zeros to a stored interferogram can create a denser plotted spectrum but adds no new measured path positions.
JPL’s TES specification lists optical-path extent, spectral sampling and resolution separately for another Fourier spectrometer. Use that separation as a reading habit, not as a source of Meteor hardware values. For an IKFS-2 result, retain the actual instrument response, calibration and processing choices. A spectrum is a carefully reconstructed measurement; atmospheric retrieval is the further inference explored in the preceding lesson.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Kozlov: radiometric calibration of IKFS-2Reviewed original-author abstract only; full article is not openly accessible. Supports the interferogram-to-spectrum workflow and stated calibration concerns, not uninspected hardware parameters.
- Read: OpenStax: the Michelson interferometerSupports path difference, interference and the doubled path change for a moving mirror. The sampled cosine example here is original.
- Read: JPL: TES instrument specificationsA comparison instrument with separately specified optical path, sampling and resolution. Its numbers are not assigned to IKFS-2.