Lesson 3 of 4 · Temporal interpolation before broadband subtraction
Compare radiation at one time
23 minute lesson · 3 checks along the way
Your goal for this lessonInterpolate a total-radiance observation to the shortwave observation time, then distinguish temporal matching from spectral-response correction.
In this lesson 4 sections · 3 checks
Read & understand
Subtract comparable observations
GERB complements SEVIRI by measuring broadband radiation from geostationary orbit. EUMETSAT identifies GERB consortium contributions from the UK, Belgium and Italy, and SEVIRI instrument leadership in Toulouse, France. GERB’s total and shortwave observations are acquired in a sequence. The 2017 GERB user guide explains that processing interpolates total-channel observations from before and after a shortwave view to the shortwave acquisition time. A changing scene makes that step consequential: subtracting values associated with different times can turn temporal evolution into an apparent difference between radiation components.
For the following original model, assume ideal, mutually compatible radiance channels already expressed in watts per square metre per steradian. Write total radiance as R(t)=S(t)+L(t), where S is the solar contribution and L the thermal contribution. This exact sum is a declared simplification. Real detector responses weight wavelengths differently, and actual GERB processing includes spectral-response and contamination corrections. Our calculation isolates time matching; it is not a recipe for subtracting arbitrary raw channel counts or published flux fields.
Read & understand
Bring the total channel to the shortwave time
Suppose total radiance is 300 at minute 0 and 340 at minute 2. A shortwave observation at minute 0.5 is 110. Assume total radiance evolves linearly between the two supplied observations. The fractional position is (0.5−0)/(2−0)=0.25, so the matched total is 300+0.25×(340−300)=310. The ideal-model thermal contribution at the shortwave time is then 310−110=200, in the same radiance units.
Using the earlier total directly would give 300−110=190, while using the later total would give 340−110=230. Their disagreement is not three independent observations of thermal variability. They combine the same shortwave sample with total measurements from different times. With the stated linear slope of 20 radiance units per minute, using a total sample half a minute too early produces a −10-unit error. The direction and size follow from the scene’s temporal slope and the time mismatch.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Interpolation supplies a model between samples
Two endpoints do not demonstrate linear evolution. Consider another allowed history R(t)=300+20t+8t(2−t), with t measured numerically in minutes. It has exactly the same values 300 and 340 at minutes 0 and 2, but at minute 0.5 its extra curved term is 6. Its total there is 316, yielding a thermal value of 206 with the same shortwave observation. Endpoint agreement therefore cannot independently validate the interpolated result of 200.
The coefficient and curvature are invented to expose this ambiguity, not to prescribe a GERB error bar. Additional trustworthy samples near the target time can test the assumed evolution. Interpolation within a bracket and extrapolation beyond it also make different demands: a target at minute 3 lies outside our observed interval. Extending the straight line to that time is an additional prediction. Keep the observation times, averaging windows and interpolation assumptions visible rather than treating a filename timestamp as a complete description of the measurement.
Put both components at one time
All values are invented radiances in watts per square metre per steradian under ideal compatible-channel assumptions. The curved history demonstrates that matching endpoint observations does not independently establish linear evolution between them. This diagram does not implement GERB spectral corrections.
Open full-size diagram in a new tab: Put both components at one timeCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Time matching and spectral correction solve different problems
The GERB shortwave unfiltering study describes how detector spectral response and narrowband information affect the conversion from measured to broadband radiance. Bringing two views to the same time does not flatten their spectral responses or remove thermal contamination from a solar channel. Conversely, a perfect response correction would not remove a mismatch between measurements of a rapidly changing scene. These steps address distinct dimensions of comparability and should not be silently substituted for one another.
Keep radiance separate from flux as well. Radiance describes a viewing direction; a hemispheric flux requires angular information or a model, beyond the subtraction performed here. The GERB guide also distinguishes snapshot products from time-averaged products. For a valid comparison, align the quantities, spatial support and temporal support before interpreting a residual. A negative ideal-model thermal result should trigger checks of those assumptions and input quality, not an automatic claim of negative emitted thermal energy. The next lesson examines another boundary: a detailed grid can combine information from instruments with very different footprints.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: GERB Level 2 User Guide, version 2.3 (2017)Complete PDF page 48 reviewed for total-to-shortwave time matching; pages 17 and 80–81 reviewed for product timing distinctions.
- Read: Unfiltering of GERB Data, Part I: Shortwave Radiation (Clerbaux et al., 2008)Historical edition-1 shortwave response correction and contamination are discussed on PDF pages 1–4 and 16; no current universal accuracy figure is claimed.