Lesson 2 of 3 · Signal persistence
Time a fault flag
9 minute lesson · 3 checks along the way
Your goal for this lessonTrace a consecutive-sample detector and bound its confirmation delay without treating persistence as proof of a physical fault.
In this lesson 4 sections · 3 checks
Read & understand
A flag and a damaged engine are different claims
KORD translated engine measurements into protective decisions. Chertok’s account describes interference and false signals capable of provoking shutdowns, including the paired response discussed in the previous lesson. The electrical path and the interpretation of its signal mattered alongside the engine being monitored. A warning could be meaningful without uniquely locating its cause.
To examine a related question, use a fictional sampled detector. It illustrates persistence: requiring a signal to remain abnormal across several samples. A 2020 NASA study describes such counters in a modern sensor-validation comparison. Neither that study nor the following example specifies KORD’s historical logic or establishes a remedy for an N1 failure.
Read & understand
Follow the counter through a reset
Our invented detector samples a dimensionless signal every 0.04 seconds. A value strictly greater than 1 adds one to a counter; a value at or below 1 resets it to zero. The first count of three confirms a flag. We examine only this first confirmation, not a later reset or actuator command.
At times 0.00, 0.04, 0.08, 0.12, 0.16 and 0.20 seconds, the readings are 0.2, 1.3, 0.4, 1.2, 1.5 and 1.1. The counter becomes 0, 1, 0, 1, 2 and 3. Confirmation arrives at 0.20 seconds. The 0.08-second sample breaks the earlier run; adding every abnormal reading since the start would implement a different rule.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Three samples do not span three intervals
The final run starts at 0.12 seconds and reaches its third sample at 0.20, an interval of 0.08 seconds. In general, N consecutive samples spaced by Δt span (N − 1)Δt from the first qualifying sample. Here that is (3 − 1) × 0.04 = 0.08 seconds.
A sustained above-threshold input can begin between samples. Assume exact sampling, no missing readings and no intervening drops below the threshold. Waiting for the first qualifying sample adds up to one further interval, so 0.08–0.12 seconds is a conservative confirmation-delay range measured from the input’s onset. If onset is at 0.09 seconds in our sequence, confirmation at 0.20 takes 0.11 seconds. Any sensor lag, processing time or physical response lies outside this simple counter model.
Follow the reset and the clock
Original sampled-detector example; not KORD logic. The counter confirms persistence, not the physical cause of the signal.
Open full-size diagram in a new tab: Follow the reset and the clockCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Persistence trades one kind of error for another
The isolated reading at 0.04 seconds does not trigger this detector. A sustained misleading signal can still reach three, and a genuine short event can disappear before confirmation. Passing the persistence test says something about the observed sequence, not that a particular engine is definitely damaged.
Increasing the required run length rejects more short runs while delaying sustained-event confirmation. That trade needs representative tests and consequences: what counts as a false flag, which real events must be detected, and how quickly a response is required. The arithmetic here compares declared rules; it cannot choose a safe operating threshold for a real rocket.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Boris Chertok: Rockets and People, Volume IVNASA’s 2011 translation, edited by Asif Siddiqi. Printed pages 146–147 describe KORD, false signals and paired shutdown; pages 208–209 discuss the first flight. A participant memoir, not a specification for this course’s fictional detector.
- Read: NASA: sensor validation and persistence countersRichardson, Wong and Melcher, NASA/TM-20205000446, October 2020. Printed page 6 explains a consecutive-cycle counter and its reset. This RS-25 sensor study is a modern comparison, not evidence of N1 software.