Lesson 3 of 4 · Interpret a laboratory assay using a matched blank and a clearly defined sample mass.
Preserve the origin of a returned sample
8 minute lesson · 3 checks along the way
Your goal for this lessonInterpret a laboratory assay using a matched blank and a clearly defined sample mass.
In this lesson 3 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
Returning material also returns a provenance problem
OSIRIS-REx collected material from Bennu in 2020 and delivered its sample capsule to Earth on September 24, 2023. Laboratory analysis can use instruments and repeated investigations that are difficult to carry aboard a spacecraft. Its value depends on knowing which substances came from Bennu and which might have entered through collection, recovery, handling or the assay itself.
NASA describes filtered air during entry and a nitrogen purge after recovery to limit terrestrial contamination. The mission team’s 2017 contamination-control paper describes witness materials exposed during assembly, testing and flight. Such records help characterize possible contamination; they do not justify assuming that every detected organic molecule is extraterrestrial. A witness material records an exposure environment, while a procedural blank follows an analytical process without the asteroid sample.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Subtract only under an explicit blank model
In a fictional assay, a 2 mg sample portion gives an apparent analyte amount of 24 ng. A matched procedural blank gives 4 ng. Assume, for this exercise, that this blank is a transferable additive contribution to the sample assay and that both amounts use the same calibration. The blank-adjusted amount is 24 − 4 = 20 ng. Divide by the actual sample mass: 20 ng / 2 mg = 10 ng/mg.
A second fictional portion has mass 4 mg, an apparent amount of 44 ng and the same 4 ng blank contribution. Its adjusted concentration is (44 − 4) / 4 = 10 ng/mg too. The larger apparent amount does not imply a larger concentration. In real analysis, blank variability, matrix effects, recovery efficiency and calibration uncertainty must be evaluated before this simple subtraction is justified. These invented assays are not Bennu measurements.
Adjust the amount, then normalize
Original diagram using the lesson’s fictional inputs and explicit assumptions; not a mission data reconstruction.
Open full-size diagram in a new tab: Adjust the amount, then normalizeCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
A portion is not an entire asteroid
When the sample and blank signals are similar, the difference may be too uncertain to support a detection claim. A negative adjusted estimate should not be interpreted as negative physical abundance. Preserve the raw results, blank results, uncertainty and detection rule; do not replace uncertain measurements with an unsupported exact zero.
Even a well-characterized laboratory portion is a subset of the material collected from one asteroid location. Grain size, mineral differences and the collection process can affect what reaches the laboratory. Connect each analyzed portion to its sample identifier, handling history and collection context. A fraction of the returned collection is not the same as a fraction of Bennu, and more precise chemistry does not automatically make a sample globally representative.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: NASA: OSIRIS-REx sample return and contamination protectionRead the sample recovery, filtered-air, nitrogen-purge and curation sections.
- Read: Dworkin and colleagues: OSIRIS-REx contamination controlThe 2017 paper’s abstract describes precision cleaning and witness materials exposed during assembly, testing and flight.