Lesson 2 of 4 · Compare atmospheric profiles while retaining reference levels, missing values and derived estimates.
Compare profiles on a common reference
8 minute lesson · 3 checks along the way
Your goal for this lessonCompare atmospheric profiles while retaining reference levels, missing values and derived estimates.
In this lesson 3 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
Read the coordinate definitions first
Pioneer Venus 2 produced several atmospheric profiles, not a complete three-dimensional map. The PDS Day Probe lower-atmosphere description defines altitude relative to the large Sounder probe’s landing site. The net-flux documentation instead describes height above a specified pressure surface. Two columns labeled kilometres therefore need not share a zero level.
For an original coordinate exercise, let reference B sit 2 km above reference A. A point 53 km above B is 55 km above A. Comparing it directly with a value at 53 km above A would compare different physical levels. Pressure can also provide a useful comparison coordinate, but a pressure-to-height conversion needs its own atmospheric assumptions.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Interpolate with an explicit assumption
Suppose a fictional profile A gives 250 K at 60 km and 320 K at 50 km, both above the same reference. Assume a straight-line change between these two samples. The midpoint at 55 km is then 285 K. If profile B measures 290 K at 55 km on that reference, the comparison is a 5 K difference. These temperatures are teaching values, not Pioneer Venus samples.
The interpolated midpoint is an estimate between measurements, not an extra direct observation. A thin layer or abrupt change between the endpoints could violate the linear assumption. Compare uncertainty, instrument response and sampling locations before attributing a difference entirely to geographic variation.
Align heights before comparing
Original teaching model; not Pioneer Venus measurements or flight specifications.
Open full-size diagram in a new tab: Align heights before comparingCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Keep flags and reconstruction history
The small-probe net-flux documentation uses 9999.00 for unavailable or unreliable values. That marker is not an enormous physical flux and must not enter an ordinary average. Keep the flag so a missing interval remains visible instead of replacing it with a plausible-looking invented observation.
The Day Probe description also identifies temperatures extrapolated after sensor breakdown. Those entries can be useful with their stated method, but should not be labeled independent thermometer readings. PDS recovery of the older records preserves opportunities for new comparisons; file conversion alone does not remove the original measurement limits.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: PDS: Day Probe lower-atmosphere data descriptionPlain-text documentation identifies ground-received time, the altitude reference and extrapolated temperatures after sensor breakdown.
- Read: PDS: small-probe net-flux data descriptionPlain-text documentation defines the upward-positive sign, corrected flux, reference surface, common grid and missing-value flag.
- Read: PDS: Day Probe backscatter labelThe XML label identifies ground-received time and the measured backscatter quantity; it is not a gas-composition table.
- Read: PDS: recovered Pioneer Venus Special Events DataThe recovered archive distinguishes atmospheric structure, scattering and radiative measurements; a common file format does not make the quantities interchangeable.