Lesson 1 of 3 · Detector normalization
Normalize detectors against a shared scene
22 minute lesson · 3 checks along the way
Your goal for this lessonRecover a piecewise detector response from matched scene measurements and distinguish relative normalization from absolute calibration.
In this lesson 4 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
Use agility to change the calibration experiment
Pleiades 1a and Pléiades-1B form the original French-led optical pair, developed within the French-Italian ORFEO cooperation. They are separate from COSMO-SkyMed’s radar system and from the later Pléiades Neo family. Their agility supports more than rapid target selection. CNES commissioning researchers deliberately changed viewing direction to make the same ground features pass across different detectors, turning spacecraft motion into a calibration experiment. CNES led the overall system, Astrium (now Airbus) built the spacecraft, and Alcatel Space (now Thales Alenia Space) developed the optical instrument. Sweden, Belgium, Spain and Austria also contributed to the programme in return for programming and archive access.
In ordinary pushbroom imaging, different detectors see different pieces of ground. Unequal counts can therefore reflect either unequal scenery or unequal detector response. The AMETHIST acquisition aligns the projected detector line with ground motion; after geometric alignment, detectors can be compared over shared scenery. The published method uses histogram matching and a nonlinear response model. Our original exercise instead fits explicit matched pairs with two straight-line response segments.
Read & understand
Fit both parts of the response
Assume stable illumination, correctly matched ground features, no saturation or noise, and a fixed sensor operating mode. Define R as the output of a chosen reference detector, in arbitrary reference-count units. At R=0,50,100,150,200, detector B reads 10,70,130,170,210. Detector C reads 20,60,100,155,210. These invented numbers are not Pléiades calibration coefficients, and R is not a known physical radiance.
For B, the slope below R=100 is (130−10)/100=1.2. Above the breakpoint it is (210−130)/100=0.8. A continuous response is B=10+1.2R for R≤100, and B=130+0.8(R−100) above it. Similarly, C=20+0.8R below the breakpoint and C=100+1.1(R−100) above it. Both rules reproduce every supplied pair. The response at the join must agree from either side; two unrelated straight lines could introduce an artificial jump.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Invert the tested branch and check a new level
To normalize B, use R=(B−10)/1.2 when B≤130, or R=100+(B−130)/0.8 above that value. For C, the corresponding boundary is C=100. Readings B=170 and C=155 both normalize to R=150. Their raw difference was an instrument difference under the stated shared-scene assumptions, not evidence that the ground changed.
A single line through B’s two endpoints would instead be B=10+R. Applied to the actual B=130 middle reading, its inverse estimates R=120 instead of 100. Matching the endpoints does not validate the response in between. An independent level R=125 should produce B=150 and C=127.5 in our model. Test intermediate levels and the intended operating range rather than extending the fitted rules beyond the observations.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Keep the reference and processing order explicit
Relative normalization makes detectors agree with the chosen reference. It does not determine that reference’s absolute radiance scale or prove that it is free of drift. Matching the wrong ground features, changing illumination or changing integration settings would also undermine the fitted relationship. The commissioning paper reports that Pléiades normalization depends on its TDI configuration; a calibration belongs to a stated instrument state.
Normalization should also retain detector identity. For separate inputs, B=70 represents R=50 and C=155 represents R=150; their normalized mean is 100. Averaging those raw readings first gives 112.5. Applying B’s low-branch inverse to that mixture gives about 85.42, an invalid substitute for the normalized mean. This simple mixing example is not a compression algorithm, but explains why detector-specific correction cannot generally be postponed until after information from detectors has been combined.
Calibrate across the whole response range
Original matched-pair calibration exercise. The reference axis is arbitrary detector counts, not an absolute radiance standard. Lines are the stipulated continuous two-branch model; dots are the five supplied matched measurements. No flight coefficients are depicted.
Open full-size diagram in a new tab: Calibrate across the whole response rangeCheck 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: CNES: the original Pléiades programmeProgramme roles, original-pair history and its relationship to ORFEO.
- Read: CNES: Pléiades history and European cooperationOverall system, spacecraft and instrument responsibilities; French-Italian ORFEO and the four additional European partners.
- Read: Blanchet and colleagues: radiometric commissioningSection 2.1 explains inter-detector normalization, AMETHIST geometry, nonlinear response and correction before compression. The exercise uses original matched pairs.