Lesson 1 of 3 · Complex samples, deramping and interpolation limits
Resample with the phase intact
25 minute lesson · 3 checks along the way
Your goal for this lessonResample a rotating complex signal using its phase model, then explain why a correction can still leave an error.
In this lesson 4 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
Start with the product that retains phase
Sentinel-1 is a C-band radar mission in the European Commission and ESA Copernicus programme. Its industrial history includes Thales Alenia Space Italy as prime contractor, Astrium Germany for the radar payload and Astrium UK for central radar electronics. The photograph shows Sentinel-1C preparing for antenna tests in 2024. These documented contributions explain the country links. This course studies image alignment through original mathematical examples; it does not infer current spacecraft status or processing accuracy from that photograph.
A Single Look Complex, or SLC, image retains two coordinates for each sample: its real and imaginary parts. Together they describe amplitude and phase. A detected Ground Range Detected, or GRD, image has lost that interferometric phase. In TOPS imaging, the antenna beam sweeps along the flight direction while acquiring bursts. The resulting phase varies rapidly across an image. Moving samples onto a common grid must respect that phase variation before the images are compared.
Sentinel-1C during launch-site preparation for antenna tests in Kourou, October 2024. This complete photograph shows hardware preparation, not an in-orbit radar image or a measured alignment result.
Look closely
What does this photograph document, and what would be needed to assess radar alignment?
See what to notice
It documents Sentinel-1C during launch-site preparation. Assessing alignment requires complex observations, processing metadata and residual checks; hardware appearance cannot establish a timing estimate.
Read & understand
Averaging coordinates can shorten a signal
Write a unit-amplitude complex sample as z=cos(φ)+i sin(φ), also written exp(iφ), where i²=−1. Its amplitude is its distance from the origin; its power is amplitude squared; its phase is the angle φ. Invent a dimensionless sample coordinate u and phase law φ(u)=πu²/2. At u=0 and u=1 the samples are 1 and i. Their ordinary linear midpoint is (1+i)/2, with amplitude 1/√2, power 1/2 and angle π/4, or 45°.
But evaluating the stipulated signal at u=1/2 gives exp(iπ/8): amplitude one, power one and phase 22.5°. The chord midpoint does not lie on the unit circle, and the quadratic phase at the midpoint is not the arithmetic mean of the endpoint phases. Both amplitude and phase have changed incorrectly. These are invented samples with a known underlying function. They reveal a failure of this interpolation rule; they are not evidence that a real Sentinel-1 product loses exactly half its power.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Remove the known rotation before interpolating
Deramping multiplies each sample by exp(−iφ) using a phase model. In our example both endpoint samples become one. Their interpolated envelope is also one. Reramping at the output coordinate multiplies by exp(iφ(1/2))=exp(iπ/8), recovering the exact midpoint of this constant-envelope model. The ESA reference-processor description obtains the phase law from image annotations. It is not a freely chosen adjustment that makes an image look smoother.
At one unchanged coordinate, the negative and positive phase factors multiply to one: deramp followed immediately by reramp is an identity and preserves amplitude. Inserting interpolation between them changes the calculation. Reramping must use the output coordinate, not merely copy a phase factor from either input sample. Consider the alternate law φ(u)=πu²: endpoints are 1 and −1, so their ordinary midpoint vanishes and has no defined phase. The correct midpoint is exp(iπ/4), still of unit amplitude.
Keep the rotating phase intact
Original constant-envelope model: z(u)=exp(i pi u²/2), sampled at u=0 and 1. Averaging those complex samples directly changes both power and phase. Deramp–interpolate–reramp recovers this exact midpoint only under the stated envelope and phase assumptions; it is not a measured Sentinel-1 loss or an arbitrary-signal reconstruction guarantee.
Open full-size diagram in a new tab: Keep the rotating phase intactCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Keep the model and interpolation limits visible
Suppose the true phase remains πu²/2 but the correction mistakenly uses πu²/4. After removing that smaller rotation, averaging and restoring it at u=1/2, the output phase is 3π/16, or 33.75°. Its power is cos²(π/8), about 0.854. The phase error is π/16, or 11.25°. A unit-magnitude correction factor cannot guarantee a correct answer when the phase model used between resampling steps is wrong.
Even the correct phase law does not make arbitrary envelope interpolation exact. Give the signal amplitude A(u)=1+u². Correct deramping leaves endpoint amplitudes one and two; their linear midpoint is 1.5, while A(1/2)=1.25. The remaining amplitude error is 0.25. Real processing therefore also needs suitable sampling, interpolation and bandwidth treatment. First preserve the complex information and establish the geometry; then estimate the small residual alignment error. The next lesson uses the overlap between adjacent bursts for that finer measurement.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Copernicus SentiWiki: Sentinel-1 missionMission and industrial-contribution context. Historical and planned status language is not used to assert the present constellation.
- Read: Copernicus SentiWiki: Sentinel-1 processingThe SLC and GRD sections distinguish retained complex phase from detected amplitude; later sections explain TOPS processing.
- Read: ESA EOPF reference processor: phase derampingEquation 5.1 describes phase removal and its inverse. This reference-processor document is not a claim about the current operational processor version.
- Read: Yague-Martinez et al.: Interferometric Processing of Sentinel-1 TOPS DataPDF pages 4–7 discuss burst-level resampling and phase treatment. Every numerical sample and diagram in this lesson is original.