Lesson 1 of 3 · Differential spectral fitting and identifiable gas signatures
Separate a gas fingerprint from the background
24 minute lesson · 3 checks along the way
Your goal for this lessonRecover two spectral amplitudes after removing a smooth background, then diagnose cross-talk and an unidentifiable fit.
In this lesson 4 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
An instrument on a weather platform
Sentinel-4 is the ultraviolet, visible and near-infrared spectrometer hosted on Meteosat Third Generation Sounder spacecraft. EUMETSAT records the first host’s launch on 1 July 2025; the archive identifies it as Meteosat 13. ESA describes repeated daytime observations over Europe and part of North Africa. Sentinel-4 is distinct from both the polar-orbiting Sentinel-5P spacecraft and the Sentinel-5 instrument on Metop-SG. The illustration shows the MTG-S spacecraft type carrying Sentinel-4; it is neither a photograph of Meteosat 13 in orbit nor an air-pollution measurement.
An imaging spectrometer records a spectrum for each scene element. The June 2026 NO₂ algorithm document fits gas-related spectral structure together with background and interfering contributions. Its operational setup is much richer than the five invented samples below. ESA identifies Airbus as instrument prime and DLR as Level-2 processor prime. The NO₂ algorithm is a joint development of IUP Bremen and KNMI. Instrument construction and the conversion of spectra into gas products require different kinds of expertise. The hardware contractor and the retrieval developers therefore contribute different parts of the measurement chain.
ESA/Mlabspace illustration of Sentinel-4 on the MTG-S spacecraft type, published on 12 December 2022. This is artwork, not a photograph of Meteosat 13 or a measured pollution map.
Look closely
Which part of the Sentinel-4 story does this illustration establish?
See what to notice
It depicts the MTG-S spacecraft type that hosts Sentinel-4. Its archive link supplies first-host context, not evidence that this is a photograph of the individual flight unit or an atmospheric retrieval.
Read & understand
Choose a model whose terms can be distinguished
Let five sample coordinates be t=(−2,−1,0,1,2). Define two dimensionless differential templates g=(1,−2,2,−2,1) and h=(−1,0,2,0,−1). They represent invented target and interfering spectral structures, not laboratory NO₂ or ozone cross-sections. A negative template value is a departure from the smooth background, not negative gas. Model a dimensionless log signal as y=c+dt+ag+bh. Suppose y=(0.019,0.013,0.030,0.015,0.023). We will recover its coefficients under equal weighting and exact calibration.
Both templates sum to zero and have zero dot product with t. Therefore c is the sample mean, 0.020, while d=(t·y)/(t·t)=0.010/10=0.001. Subtract c+dt to leave residual structure r=(0.001,−0.006,0.010,−0.006,0.001). A dot product means multiply corresponding entries and add them. Removing this stipulated linear background does not prove that every real background is linear. The actual algorithm uses many wavelengths and a higher-order polynomial; five values are only an algebraic demonstration.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Fit the interfering structure as well
The templates are not mutually orthogonal: g·g=14, h·h=6 and g·h=2. Their correlations with r are g·r=0.046 and h·r=0.018. The least-squares normal equations are consequently 14a+2b=0.046 and 2a+6b=0.018. Their determinant is 14×6−2×2=80, so the two amplitudes are distinguishable in this declared model. Solving gives a=0.003 and b=0.002. Substitution reproduces all five observations, including the central value 0.030.
If we omit h and fit only g, the estimate becomes a=0.046/14≈0.003286, about 9.52% higher than 0.003. Some interfering structure has been assigned to the target. That percentage is specific to our invented templates and amplitudes. It is not a Sentinel-4 error estimate. Conversely, adding a constant offset of 0.010 to every sample changes c but leaves these two amplitudes unchanged, because both templates have zero mean. Which correction matters depends on its spectral shape.
Separate two spectral fingerprints
The background-orthogonal templates still overlap each other. A joint fit recovers both amplitudes; omitting one assigns some of its structure to the other. The numbers are original teaching values, not Sentinel-4 cross-sections or performance specifications.
Open full-size diagram in a new tab: Separate two spectral fingerprintsCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Ask what an excellent fit can conceal
If an unrecognized calibration artifact adds 0.001g, the fitted target coefficient becomes 0.004 while b stays 0.002. All samples still fit perfectly. A zero residual checks agreement with the available model; it cannot establish that the target-shaped contribution came from a gas. Independent calibration and physically justified reference spectra are therefore essential. Nor are a and b already vertical gas columns: their present units and normalizations are those of our constructed templates.
Extra flexibility can remove identifiability. Consider adding a quadratic-background vector q=t²−2=(2,−1,−2,−1,2). Here q=0.5g−1.5h exactly. If its coefficient e is also free, the data constrain only a+0.5e and b−1.5e. For example, (a,b,e)=(0.003,0.002,0) and (0.0025,0.0035,0.001) produce identical spectra. More fitted terms did not create more information. This counterexample concerns our five-sample design, not a claim that the real processor’s polynomial is degenerate.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: ESA: Sentinel-4 spectrometerInstrument, reflected-sunlight spectral measurements and regional daytime observing purpose. The five-sample templates are original teaching values.
- Read: Sentinel-4 NO₂ algorithm, issue 4.5Verified PDF cover: 30 June 2026. Sections 4.5 and 5.2 describe the spectral fit and interfering terms; the lesson’s degree-one background and five samples are deliberately reduced.
- Read: ESA: Sentinel-4 facts and responsibilitiesIdentifies Airbus instrument and DLR Level-2 prime responsibilities. The hosted instrument remains separate from its spacecraft.