Lesson 3 of 3 · Finite-domain emission budgets, chemical lifetime and nonlinear averaging
Account for loss before estimating emissions
24 minute lesson · 3 checks along the way
Your goal for this lessonRecover an emission rate from a finite-domain transport estimate, test lifetime sensitivity and correct each observation before averaging.
In this lesson 4 sections · 3 checks
Read & understand
Keep the integration area in the units
The 2023 source catalog integrates its corrected advection field and accounts for chemical loss while gas travels across the integration region. Our reduced model assumes an isolated steady source, a narrow downwind plume, uniform nondivergent wind, flat terrain, a consistent NOₓ mass convention and first-order removal with constant lifetime τ. It omits the paper’s topographic and retrieval adjustments. Its numbers illustrate the budget, not an emission estimate for a real facility.
Let I be the net spatial integral of the advection field, including negative as well as positive contributions. As a unit exercise, three cells of 10 km² each with values 1, 2 and 3 mg/m²/h contribute I=60 kg/h; assume all remaining cells sum to zero. One mg/m² multiplied by one km² equals one kg. Summing the values without areas would give a different quantity. A partial or differently sized integration region cannot be compared merely by counting its cells.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Replace gas lost before the boundary
For a narrow plume travelling a distance R at speed w, residence time is tᵣ=R/w. First-order removal leaves a surviving fraction exp(−tᵣ/τ). Integrating the steady budget from the source to that boundary gives I=E exp(−R/(wτ)), where E is the source emission rate. Thus E=I exp(R/(wτ)). The positive exponent reverses loss. It is not the fraction of the original gas that remains.
Use I=60 kg/h, R=12 km, w=6 km/h and τ=4 h. Residence time is 2 h, the dimensionless exponent is 0.5, and E=60 exp(0.5)≈98.92 kg/h. About 60.65% of the emitted gas survives to the boundary in this model. The corresponding integrated chemical loss is E−I≈38.92 kg/h. Adding that loss back recovers the source budget. The example uses a 12 km radius, deliberately distinct from the paper’s 15 km choice.
Reverse loss within a finite region
Original isolated steady-plume model with uniform wind and first-order removal. The curve is a survival fraction, while the source correction uses its reciprocal; neither is a measured TROPOMI performance curve.
Open full-size diagram in a new tab: Reverse loss within a finite regionCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Ask which assumptions the data can constrain
Holding I, R and w fixed, a lifetime of 2 h gives E=60 exp(1)≈163.10 kg/h; a lifetime of 8 h gives E=60 exp(0.25)≈77.04 kg/h. The interval from 77.04 to 163.10 is a sensitivity range for specified lifetimes, not a statistical confidence interval. Locally, d ln E/d ln τ=−R/(wτ)=−0.5 at the original setting. A small fractional lifetime increase therefore produces about half as large a fractional decrease in E, under the fixed-input assumption.
Two nested boundaries can test this idealized model. At R₁=6 km and R₂=12 km with w=6 km/h, let I₁=80 exp(−0.25) and I₂=80 exp(−0.5) kg/h. Then ln(I₁/I₂)=0.25 and τ=(R₂−R₁)/(w ln(I₁/I₂))=4 h; either boundary recovers E=80 kg/h. This inference requires the same isolated steady source and transport assumptions. Nearby sources, changing winds, footprint smearing or missing areas can invalidate that interpretation of the ratio.
Read & understand
Correct compatible observations before averaging
Consider two equal-duration cases with the same true E=100 kg/h, R=12 km and τ=4 h, but winds of 6 and 12 km/h. Their respective integrals are I₁=100 exp(−0.5)≈60.65 and I₂=100 exp(−0.25)≈77.88 kg/h. Correcting each with its own wind returns 100 in both cases. Their average corrected emission is therefore 100 kg/h, as the stipulated source requires.
Using the average integral and average wind instead gives [(I₁+I₂)/2] exp(12/(9×4))≈96.67 kg/h. The exponential operation and averaging do not commute, and I also changes with wind. In real work, changing wind would additionally change the advection calculation itself. Preserve each observation’s wind, lifetime assumptions, usable area and selection before forming an aggregate. A mathematically consistent correction still needs independent checks of retrieval, transport and source isolation.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Beirle and colleagues: lifetime correction and source estimatesSections 3.10.1–3.10.3 and Appendix B derive the integrated loss correction. The 12 km model, sensitivity range and two-case averaging exercise are original.
- Read: ESA: Sentinel-5P mission and data chainPlaces these inferred scientific quantities downstream of the satellite, receiving stations and processing system.