Lesson 3 of 3 · Thermal motion and passive focus compensation
Keep the detector at focus
24 minute lesson · 3 checks along the way
Your goal for this lessonCompare thermal motion of an optical focus and detector support, design a simple compensating support and test its sensitivity to unequal temperatures.
In this lesson 4 sections · 3 checks
Read & understand
A stable focus is a relative position
The SAP announcement describes planned LEOCAM testing aboard the International Space Station. LightHaus’s product description identifies reflective three-mirror optics and passive athermalization. That description motivates this lesson; it does not disclose enough geometry to reconstruct the camera or prove its hosted flight performance. The model below is an original one-dimensional optical assembly, not LEOCAM’s prescription, support material or qualification limit.
Measure focus position f and detector position L from the same fixed reference along the optical axis. Define signed defocus δ=f−L. Positive δ means the focus is farther from the reference than the detector; negative δ means it is nearer. Initially both are 200 mm and δ=0. Athermal behavior in this model means matching their changes. Neither the optical assembly nor the support needs to remain at constant temperature, and neither position needs to remain fixed.
Read & understand
Subtract the two thermal motions
Assume uniform heating, small changes and constant effective coefficients. Let the focus change by βf₀ΔT and a simple support length change by αL₀ΔT, with coefficients expressed per kelvin. Assign β=15×10⁻⁶/K and α=5×10⁻⁶/K. For a 20 K rise, the focus moves +0.060 mm, or +60 micrometres, while the detector moves +0.020 mm, or +20 micrometres. Defocus is therefore +40 micrometres. Subtracting coefficients without also including length and temperature would not produce a displacement.
With the same coefficients and a 20 K fall, the motions reverse and δ=−40 micrometres. If α instead equals β and L₀=f₀, their uniform-temperature shifts cancel to first order. Choosing the lowest-expansion support is not automatically best: setting α=0 here leaves +60 micrometres of defocus for the warm case. The useful property is matching the optical focus motion. Our effective β is assigned directly; no refractive-glass formula is substituted into LEOCAM’s reflective optical design.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Combine two support lengths
Replace the single support with two collinear segments in series. Assume no bending, joint motion or reference drift. Segment A is 120 mm long with αA=5×10⁻⁶/K; segment B is 80 mm with αB=30×10⁻⁶/K. Their total length is still 200 mm. Under uniform heating, detector motion is (αA LA+αB LB)ΔT. The coefficient of ΔT is 0.0006+0.0024=0.0030 mm/K, equal to the assigned optical focus sensitivity.
For a 20 K rise, A contributes 12 micrometres and B contributes 48 micrometres, matching the +60 micrometre focus shift. The effective support coefficient is length-weighted: 0.0030/200=15×10⁻⁶/K. The unweighted average, 17.5×10⁻⁶/K, would incorrectly predict +70 micrometres. Material proportions and geometry matter. These invented coefficients name no actual alloys or glasses, and a serial rod model omits the three-dimensional deformations of a real instrument.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Break the uniform-temperature assumption
Now let the optical assembly warm by 20 K, segment A by only 10 K and segment B by 20 K. Optical motion remains +60 micrometres, but support motion becomes 6+48=54 micrometres. Residual defocus is +6 micrometres. A design that cancels uniform heating can still respond to a gradient. One temperature reading cannot establish that all components followed the same thermal history.
For a second original single-support model, start with f₀=L₀=100 mm, β=20×10⁻⁶/K and α=10×10⁻⁶/K. A 30 K rise produces +60 and +30 micrometre motions, leaving +30 micrometres of defocus. These position differences are not resolved ground detail, a diffraction limit or an acceptance threshold. Testing a real hosted imager requires optical measurements across relevant temperatures, gradients, mounting and deployment states. Passive compensation can reduce one sensitivity while leaving alignment, timing and other image-quality errors to be evaluated separately.
Relative thermal motion controls focus
Original linear, one-dimensional model. Defocus is focus position minus detector position from the same reference. The displacement axis uses micrometres and support bars preserve their 120:80 length ratio; this is not a LEOCAM optical drawing or a resolution claim.
Open full-size diagram in a new tab: Relative thermal motion controls focusCheck 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: LightHaus: LEOCAM optical payloadComplete product description read. Passive athermalization motivates an independent model; advertised values and readiness are not substituted for SAP flight results.
- Read: Edmund Optics: passive athermalizationThermal Defocus section and equations 1–4 reviewed. The linked figure could not be retrieved. The lesson defines its own signed coordinate model and does not transfer the page’s refractive IR approximation to reflective LEOCAM optics.
- Read: NTU: planned hosted imagingThe February 2026 release describes an intended ISS demonstration; it does not establish completed deployment or optical validation.