Lesson 2 of 4 · Band ratios and their limits
Interpret a band ratio
17 minute lesson · 3 checks along the way
Your goal for this lessonCompute a fictional NIR/SWIR contrast, handle missing/zero-denominator evidence and distinguish a changed index from a crop diagnosis.
In this lesson 3 sections · 3 checks
Read & understand
Calculate a contrast with a defined denominator
A normalized difference moisture index uses near-infrared and shortwave-infrared reflectance. For this exercise call those nonnegative values N and S, and define I = (N − S) / (N + S), provided N + S is positive. The NASA HLS reference gives this form for its relevant bands. Using a familiar equation does not establish that an unreviewed sensor or product is interchangeable with HLS.
With fictional N = 0.60 and S = 0.20, the numerator is 0.40 and the denominator is 0.80, so I = 0.50. This is a dimensionless contrast, not “50 percent water.” If both inputs are zero, the formula gives zero divided by zero and is undefined. Preserve that case as missing or invalid evidence; replacing it with a valid zero index would invent a measurement.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Ask which changes the ratio can distinguish
Now halve both reflectances: N = 0.30 and S = 0.10. The numerator becomes 0.20 and the denominator 0.40, leaving the index at 0.50. More generally, multiplying both inputs by the same positive factor cancels from the ratio. Consequently, the index alone cannot recover the original pair of reflectances. Retaining the band values provides information lost by retaining only their contrast.
In a different fictional observation, keep N at 0.60 but increase S to 0.30. The index becomes 0.30 / 0.90 = 1/3. That calculation demonstrates a change in the defined contrast. It does not identify a unique cause in a real field. The common-factor cancellation is an algebraic property, not proof that the ratio removes every atmospheric, illumination, calibration or surface difference.
Different reflectances and their normalized contrasts
Original arithmetic examples using nonnegative reflectances. The ratio alone does not recover the input pair or diagnose crop condition.
Open full-size diagram in a new tab: Different reflectances and their normalized contrastsRead diagram data as a table
| N | S | I |
|---|---|---|
| 0.60 | 0.20 | 1/2 |
| 0.30 | 0.10 | 1/2 |
| 0.60 | 0.30 | 1/3 |
| 0.00 | 0.00 | Undefined |
Original arithmetic examples using nonnegative reflectances. The ratio alone does not recover the input pair or diagnose crop condition.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Check suitability before interpreting change
A time comparison needs suitable observations of the same intended target. Examine dates, locations, band definitions and quality information before treating two numbers as a trend. HLS supplies quality flags for conditions such as clouds and shadows; those flags are part of interpreting its products. The existence of a numerical index is not itself evidence that its input observations are suitable for the question.
Suppose an exercise rule marks values below 0.25 for review. That is an arbitrary teaching rule, not an agronomic threshold or irrigation instruction. A flagged field would still need context and corroboration. The next lesson shows a specific reason: an unchanged crop can yield a different pixel-level contrast when the proportion of visible background changes. The arithmetic can be correct while the biological conclusion is unsupported.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.