Lesson 3 of 3 · Contamination and ordered statistics
Choose a reference statistic
24 minute lesson · 3 checks along the way
Your goal for this lessonCalibrate and compare mean-based and ordered-statistic thresholds at the same nominal rate, then test their different responses to contaminated references.
In this lesson 4 sections · 3 checks
Read & understand
Separate the reference statistic from its multiplier
One unusually large reference intensity can raise a mean and conceal a test-cell excess. An ordered-statistic detector instead sorts the references and selects a stated rank. With four references, let Y(3) be the third smallest, which is also the second largest. Use threshold αY(3). This statistic is not automatically the background mean, and its multiplier must be calibrated for its own distribution.
Retain the previous independent, same-mean exponential background model. There are four choices for the sample occupying rank three and three choices for the two values below it. Combining their probabilities gives density f3(y)=(12/µ)exp(−2y/µ)[1−exp(−y/µ)]² for y≥0. This rank distribution describes repeated sets of four references; sorting one observed set does not establish that its assumptions hold.
Read & understand
Calibrate an original ordered-statistic example
The false-alarm probability is the integral of exp(−αy/µ)f3(y). Substitute u=y/µ and expand the square to obtain p=12[1/(α+2)−2/(α+3)+1/(α+4)]. Combining the fractions gives p=24/[(α+2)(α+3)(α+4)]. For α=6, p=24/(8×9×10)=1/30, or about 3.33%. The unknown common mean cancels.
A fair comparison must give the cell-average method this same nominal rate. With N=4, its multiplier is 4[30^(1/4)−1]≈5.36139, not 6 and not the earlier 8.64911. Different estimators need different factors. Equal factors would generally mean different background false-alarm rates, making an apparent advantage difficult to interpret.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Change one reference and recalculate both thresholds
Start with references 2,3,4,7 and a test intensity X=40. The mean and third-smallest value both happen to be 4. The calibrated cell-average threshold is approximately 21.4456; the ordered-statistic threshold is 24. The test cell exceeds both. This equality of the two observed reference statistics is a feature of this fixture, not a general identity.
Now replace only the largest reference, 7, with 100. The mean becomes 27.25 and its threshold rises to about 146.098, so X=40 is no longer flagged. The third-smallest value remains 4, keeping its threshold at 24 and its flag unchanged. The isolated high outlier has masked this test-cell excess for the mean-based rule. This single fixture demonstrates sensitivity to contamination; it does not measure detection probability or establish what caused the test-cell brightness.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Find the limit of the apparent robustness
Replace two references instead, giving 2,3,100,101. The third-smallest value is now 100 and its threshold is 600, which also hides X=40. Rank three can resist changes confined to the largest reference, but it cannot reject an arbitrary number or pattern of contaminated values. Lower-valued contamination and background boundaries create other problems. Guard regions and background validation still matter; selecting an order statistic does not make them universally unnecessary.
Finally separate three claims: the chosen rules have equal nominal rates under the homogeneous model; they respond differently to the supplied outlier; and neither has a demonstrated real-image success rate here. Evaluating that last claim requires representative background and known-object examples, with product processing, geometry and evaluation criteria stated. A threshold study supports a particular decision rule under particular evidence. It does not turn every bright return into a named object or certify an operational COSMO-SkyMed product.
Match nominal rates, then test contamination
Original four-reference contamination fixtures. Equal nominal rates assume independent common-mean exponential background samples. The changed fixtures show sensitivity to outliers; they do not measure real-scene detection probability or establish object identity.
Open full-size diagram in a new tab: Match nominal rates, then test contaminationCheck 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.