Lesson 1 of 3 · Background-tail probability
Define a radar brightness threshold
20 minute lesson · 3 checks along the way
Your goal for this lessonSet an intensity threshold from a stipulated background distribution and distinguish a false-alarm probability from object identity.
In this lesson 4 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
Start with the measurement, not the display color
COSMO-SkyMed is Italy’s X-band radar constellation, developed through ASI and the Ministry of Defense. COSMO 1 began the first generation in 2007; COSMO-SkyMed Second Generation, or CSG, continues the programme. Thales Alenia Space supplies the spacecraft and Telespazio the ground segment and operations. France’s Pléiades provides a separate optical partner through ORFEO. Argentina’s SAOCOM contributes separate L-band radar observations through SIASGE. These partnerships combine different measurements rather than making all their pixels interchangeable.
ASI’s 2021 CSG product description distinguishes focused complex samples from detected amplitude products, some with optional multilooking. For a complex sample Z=I+iQ, define linear intensity X=I²+Q² and amplitude √X. If I=3 and Q=4, intensity is 25 and amplitude is 5. Display colors, logarithmic brightness and an average of several looks are different quantities. Read the product definition before choosing a probability model.
Read & understand
State a background-only model
Suppose a homogeneous patch contains only the background process of interest. In this original exercise, I and Q are independent zero-mean Gaussian variables, each with variance µ/2. Their squared sum X then has an exponential distribution with positive mean µ. Its density is f(x)=exp(−x/µ)/µ for x≥0. This is a stipulated single-look intensity model, not a universal distribution for every land cover, sea state or processed COSMO-SkyMed image.
Flag a cell when X exceeds threshold T. Integrating the density above T gives the background-only false-alarm probability p=exp(−T/µ). Solving for the threshold gives T=−µ ln p, where ln is the natural logarithm. For known µ=4 intensity units and desired p=0.01, T≈18.4207. A measured intensity of 25 exceeds this threshold; a value of 12 does not. The model uses a strict greater-than rule; equality has zero probability for its continuous distribution.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Keep the scale and the meaning of probability straight
The equivalent amplitude threshold is √18.4207≈4.2919. Comparing amplitude 5 against intensity threshold 18.4207 mixes units and reverses the example decision. Squaring the amplitude or taking the square root of the intensity threshold preserves the intended comparison. It does not make amplitude exponentially distributed: the exponential assumption belongs to X, not √X.
The stated 1% is the probability that a background-only cell crosses the threshold under this model. It is not a 99% probability that a flagged cell is a ship, a building or any other particular object. That inference would require information about alternative causes, their prevalence and how often the detector responds to them. A published ASI-funded COSMO-SkyMed research study used a statistical pre-screen before further grouping and rejection steps; a threshold crossing was only part of its analysis.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Test what happens when the background changes
Keep T=18.4207 but let the actual background mean double from 4 to 8. The false-alarm probability becomes exp(−18.4207/8)=0.10. A threshold calibrated for one background can therefore produce ten times the intended false-alarm rate in another. This is an exact consequence of the stipulated exponential model, not a measured rate for the constellation.
The SAOCOM 1A image shown here is a processed CONAE view of Córdoba countryside, included as SIASGE partner context. Its fields and hills illustrate heterogeneous scenery; its colors do not supply the linear intensities, channel definition or independent samples needed to test our model. Neither this image nor the mathematical exercise establishes a current COSMO-SkyMed fleet count. ASI’s January 2026 FM3 release records a launch and a future addition to operations; launching a spacecraft and commissioning its service are different milestones.
A threshold depends on the background model
Original exponential-background exercise. Both axes and all numbers belong to linear intensity units, not display colors or observed COSMO-SkyMed performance. Curves show background-only exceedance probabilities, not probabilities of an object given a flag.
Open full-size diagram in a new tab: A threshold depends on the background modelCONAE radar view from SAOCOM 1A, the separate L-band SIASGE partner of X-band COSMO-SkyMed. This processed Córdoba countryside image is context, not a COSMO-SkyMed acquisition or a dataset for the threshold exercises. Acquisition date and numeric channel mapping are not supplied. Full frame retained; delivery resized and encoded as WebP.
Look closely
Can this partner image supply the independent linear intensities required by the threshold exercise?
See what to notice
No. This processed SAOCOM 1A image shows fields and hills, but lacks the numeric channel definition and independent samples needed for that calculation. It is CONAE SIASGE partner context, not a COSMO-SkyMed acquisition. The complete frame, credit and CC BY 4.0 license remain attached to its exact archive owner.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: ASI: COSMO-SkyMed programmeProgramme responsibilities and generations; mixed dated operational totals are not used as a current count.
- Read: ASI: CSG system and products, revision A (2021)Pages 32–43, especially 37–40, distinguish complex samples, amplitude detection and optional multilooking. No flight false-alarm rate is inferred.
- Read: ASI: SIASGE cooperationItalian X-band and Argentine L-band systems remain distinct partners.
- Read: CNES: Pléiades cooperationHistorical French-Italian ORFEO relationship.
- Read: ASI: CSG-FM3 launch, January 3, 2026Dated launch and future operational addition; not evidence of its later commissioning.
- Read: Rohling: radar CFAR thresholding (1983)Sections III–IV establish the independent exponential reference model. All numerical exercises here are original.
- Read: Bacci and colleagues: ICOSSOP (2013)Section 2 describes a COSMO-SkyMed research pre-screen followed by further candidate processing; this course does not reproduce an operational pipeline.