Lesson 2 of 3 · Additive and multiplicative detail transfer
Compare fusion rules
25 minute lesson · 3 checks along the way
Your goal for this lessonCalculate two detail-injection rules, identify their preserved quantities and diagnose clipping.
In this lesson 4 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
Start from an explicit model
Pansharpening methods differ in how they transfer detail into the bands. For a small original exercise, repeat coarse R=20 and N=60 in two fine cells. Define synthetic intensity I=(R+N)/2=40, and suppose the measured fine panchromatic values are P=(30,50). Assume matching units, exact alignment and equal spectral weights. These conditions isolate the calculation; they are not a DS-EO product specification.
The 2015 comparison paper expresses several component-substitution methods as a base band plus a gain times P−I. We examine a unit-gain additive rule and a multiplicative rule. These are transparent teaching cases, not a ranking of operational methods. Real preprocessing must address different spectral responses, calibration, registration and noise before such formulas can support an application.
Read & understand
Add the brightness difference
The additive rule is F_R=R+(P−I) and F_N=N+(P−I). Here P−I=(−10,+10), so the output bands are F_R=(10,30) and F_N=(50,70). Their means remain 20 and 60 because the injected differences average to zero. At each fine cell, the mean of the two output bands equals the specified panchromatic value: 30 and 50.
Now inspect the normalized band contrast C=(N−R)/(N+R), using positive denominators. The original contrast is 40/80=0.5. The additive output gives 40/60=2/3 in the first cell and 40/100=0.4 in the second. Adding the same amount preserves the band difference, but changes the sum. Preserved coarse means do not imply that this nonlinear contrast stays unchanged at fine scale.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Multiply by a common factor
The multiplicative rule is F_R=R×P/I and F_N=N×P/I, requiring nonzero I. The factors are 0.75 and 1.25, producing F_R=(15,25) and F_N=(45,75). The means again remain 20 and 60. The equal-weight synthetic panchromatic values are again 30 and 50. Both rules therefore pass those same consistency checks while producing different fine color values.
With a common positive factor k, the contrast becomes (kN−kR)/(kN+kR)=(N−R)/(N+R). It stays 0.5 in both cells. That algebraic property is useful to identify, but it is also an assumption about the unresolved variation. A constant fine contrast is not proven correct merely because the fusion rule preserves it. Another surface could have fine spectral changes that the available coarse measurements do not resolve.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Check limits before displaying the result
Change only P to (5,75), keeping mean P=40. The additive red output becomes (−15,55), while N becomes (25,95). If the intended physical quantities must be nonnegative, the negative red value reveals a problem with this simple model. Clipping it to zero gives red mean 27.5 instead of 20. A display can look tidier while breaking the original coarse-band constraint.
Keep a record of clipping, masks and the unmodified values, and revisit the model or preprocessing. Multiplicative injection has its own limit when I is zero or very small: a ratio can be undefined or amplify error. Digital Earth Australia’s worked example likewise distinguishes a visually useful fused product from demonstrated spectral fidelity. Evaluate the quantities the application will use, rather than treating one preserved property as complete validation.
Check what each fusion rule preserves
Original two-band calculations with matching units and equal spectral weights. These are not DS-EO processing coefficients.
Open full-size diagram in a new tab: Check what each fusion rule preservesCheck 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Vivone and colleagues: component substitution methods2015 paper, pages 2–5 reviewed; equations (1)–(5) and Figure 1 inspected. Original two-band examples are not mission algorithms or performance results.
- Read: Digital Earth Australia: pansharpening methods and assessmentRelevant method and evaluation sections reviewed. Landsat-specific band weights and outcomes are not transferred to DS-EO.