Lesson 3 of 3 · Reference tests and complementary error measures
Test at another scale
25 minute lesson · 3 checks along the way
Your goal for this lessonDesign a reduced-resolution comparison and explain why agreement on one metric or scale does not prove full-resolution accuracy.
In this lesson 4 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
Create a test with a measured reference
A fine multispectral reference is usually missing in the actual fusion problem. The 2021 benchmarking paper describes a reduced-resolution test: degrade both inputs, fuse them at the new scale, and compare the result with the original multispectral image. The reference is kept out of the fusion input at that scale. This tests reconstruction against measurements instead of judging only the attractiveness of the output.
Use an original scale exercise with PAN spacing 0.5 m and multispectral spacing 2 m. Their linear ratio is four. Degrade both by four: PAN becomes 2 m and multispectral becomes 8 m. Fuse toward a 2 m output, then compare with the original 2 m multispectral data. Spatial degradation needs suitable low-pass filtering before decimation. Simply skipping samples can alias fine structure and change what the experiment measures.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Match the test to the acquisition
The benchmark emphasizes sensor-dependent filtering and careful alignment. A convenient block mean is useful for our arithmetic, but it is not a verified model of DS-EO’s optics or delivered products. State filters, sampling offsets, masks, borders and units. Compare candidate methods using the same prepared inputs, and keep the reference out of parameter tuning if it is being used as a final test.
Performance at the reduced scale does not automatically transfer to the finest scale. The assumption that a method behaves similarly across scales needs scrutiny: small roofs, vegetation textures, shadows and spectral boundaries can change the difficulty. Evaluate multiple representative scenes and inspect full-resolution spatial and spectral behavior as well. One successful crop cannot establish a universal best method.
Read & understand
Measure direction and magnitude separately
For an original two-band reference vector x=(3,4), compare A=(6,8) and B=(4,3). The spectral angle is arccos[(x·y)/(|x||y|)]. A is a positive multiple of x, so its angle is zero even though both values are doubled. B has dot product 24 and norm product 25, giving arccos(24/25), about 16.26 degrees. Angle favors A because it assesses direction rather than absolute magnitude.
Compute RMSE across these two band entries. A has errors (3,4), so RMSE=√[(9+16)/2]≈3.54. B has errors (1,−1), giving RMSE=1. This measure favors B. Neither metric is broken; they answer different questions. Report both with the units and aggregation rule. Spectral angle is undefined for a zero vector, so a valid mask and documented handling are necessary.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
A consistency check is not a hidden reference
Return to coarse R=20, N=60 and P=(30,50). Suppose a separate reference at the test scale contains R=(5,35), N=(55,65). It matches those coarse means and panchromatic values. The earlier additive output has four errors (5,−5,−5,5), giving RMSE=5; the multiplicative output has (10,−10,−10,10), giving RMSE=10. Under this reference and metric, the additive result is closer. A different compatible reference can reverse that comparison.
Both methods had already passed the coarse consistency checks. Those checks could not supply this ranking because averaging discards fine differences. For a DS-EO mapping workflow, retain original imagery and metadata, preprocessing, fusion settings, masks and the scope of validation. Deliver the fused view with evidence about the actual quantities used for analysis, while keeping estimated detail distinct from independently measured fine color.
Test at a scale with reference data
Original scale exercise and two-band metrics. Sensor-appropriate degradation and alignment matter; scale invariance is an assumption to examine.
Open full-size diagram in a new tab: Test at a scale with reference dataCheck 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Vivone and colleagues: benchmarking protocolComplete 17-page text reviewed. Reduced-resolution protocol, scale-invariance limitation and spectral-angle equation checked in page renders. No DS-EO benchmark data or universal ranking inferred.
- Read: Digital Earth Australia: spatial and spectral evaluationWorked Landsat comparisons are scene-specific. Correlation alone does not establish absolute value accuracy.
- Read: ST Engineering Geo-Insights: DS-EO datasheetSeparate panchromatic and multispectral specifications motivate the scale comparison; original errors and reference vectors are invented.