Lesson 2 of 3 · Thermal paths and the limits of substitute loads
Match temperature and test function
24 minute lesson · 3 checks along the way
Your goal for this lessonCalculate temperatures at explicitly defined locations in a one-path thermal model and identify which functions a substitute-load test leaves unverified.
In this lesson 4 sections · 3 checks
Read & understand
A test result needs an operating condition
The ELITE qualification paper reports nominal thermal performance, a failure during hotter stress testing, and a successful retest referenced to PPU casing temperature. Its long-duration resistor-load tests omitted gas flow. These are different conditions and functions, not one universal pass. Keep the failure and retest together when reading the evidence.
A statement such as “tested at 50°C” is incomplete unless it identifies the sensor location, operating mode, duration and relevant limits. A chamber controller, mounting plate, equipment casing and semiconductor junction can all have different temperatures at the same moment. Changing which temperature is controlled or recorded can change the meaning of an apparently identical number.
Read & understand
Follow heat through explicitly defined locations
Use an original ideal steady-state model with one heat source and one conduction path. All 15 W generated at a hot internal node flows first through 0.8°C/W to the casing, then through 1.2°C/W to a mounting plate held at 30°C. Ignore radiation, other components and alternative paths. Temperature rise across a segment is heat flow times that segment’s thermal resistance. The casing is at 30+15×1.2=48°C, and the hot node is at 48+15×0.8=60°C.
For invented limits of 50°C at the casing and 65°C at the hot node, the margins are 2°C and 5°C respectively. Substituting the plate’s 30°C reading for the casing reading would falsely report 20°C of casing margin. Substituting total bus input for the 15 W of internal heat would also change the model. Electrical power exported to a load outside the modeled module is not automatically dissipated inside it.
These resistances define this complete one-path exercise; they are not package data-sheet values transferred into a spacecraft. Texas Instruments explains why a junction-to-case resistance measured with a cold plate cannot generally be multiplied by total chip power in an ordinary board installation. Heat can split among several paths, and the relevant surface and boundary conditions must match. Our simple calculation is valid because its restrictive heat-flow assumptions were stated explicitly.
An explicit thermal path connects three different temperatures
Original ideal model with no parallel heat paths or radiation. Its effective resistances are defined for this exercise; they are not transferred package specifications or measured ELITE values.
Open full-size diagram in a new tab: An explicit thermal path connects three different temperaturesCheck 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Carry contact and operating changes into the limit
Suppose mounting contact deteriorates, raising only the casing-to-plate resistance from 1.2 to 1.6°C/W. At 15 W and the same 30°C plate, the casing reaches 54°C and the hot node 66°C. Both invented limits are exceeded. The unchanged chamber or plate reading cannot reveal this change without additional observations or a validated model.
With the original resistances, a 50°C casing limit allows at most (50−30)/1.2≈16.67 W of internal heat. The 65°C hot-node limit allows (65−30)/(0.8+1.2)=17.5 W. Both constraints apply, so the smaller value governs. Those calculations describe steady state only. A short run before thermal equilibrium could record lower temperatures and fail to establish the stated continuous operating capability. There is no measured ELITE thermal resistance or allowable heat load hidden in these invented numbers.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
State what the substitute actually exercises
An external resistor can draw electrical output while avoiding a live plasma discharge. For an original load at 300 V and 75 W, Ohm’s law gives R=V²/P=1200 ohms and I=P/V=0.25 A. If that resistor is outside the modeled module, its 75 W heats the resistor’s location. Converter losses still heat the converter. The placement matters to the thermal test.
Such a test can investigate electrical loading and temperature under its setup. Without flowing gas or an operating thruster, it does not directly verify gas regulation, ignition or thrust. A useful coverage table therefore records pass, fail and not exercised separately for each required function. Preserve the exact test article, modifications, sensor locations and retest conditions. A pass after a repair supports that tested configuration; it does not erase the earlier anomaly or establish every untested mode.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Aliena: thermal-vacuum tests and functional coverageSection IV.B.1 and Figures 6–7; retain the distinctions between nominal, stress and retest conditions.
- Read: Texas Instruments: semiconductor thermal metricsSection 2 and Figure 2-1 explain measurement boundaries and invalid uses of junction-to-case resistance. The course uses its own explicitly defined one-path model.