Lesson 3 of 3 · Spectral density, RMS and frequency-dependent response
Read the vibration spectrum
25 minute lesson · 3 checks along the way
Your goal for this lessonIntegrate acceleration spectral density, scale RMS correctly, and compare frequency-dependent responses without treating an overall level as a complete test specification.
In this lesson 4 sections · 3 checks
Read & understand
An overall level does not specify a whole test
ELITE’s published qualification record includes separate vibration profiles by axis, response comparisons before and after exposure, and functional-test outcomes. This invites a more precise question than whether hardware “survived shaking”: what input was applied, how did the hardware respond, and which functions still worked?
For stationary zero-mean random acceleration, a one-sided power spectral density S(f) distributes mean-square acceleration over nonnegative frequencies. In this lesson its units are g²/Hz, where g represents standard gravitational acceleration. Integrating S over frequency gives mean square in g²; taking the square root gives RMS acceleration in g. RMS is not an instantaneous maximum. The NASA vibration handbook develops this relationship and explains why a finite measurement record has uncertainty.
Read & understand
Add spectral areas before taking the square root
Consider an original ideal profile that is flat at 0.04 g²/Hz from 100 to 200 Hz and at 0.01 g²/Hz from 200 to 600 Hz, with zero density elsewhere. The first band contributes 0.04×100=4 g². The wider second band contributes 0.01×400=4 g². Total mean square is 8 g², so overall RMS is √8≈2.828 g. Adding the two band RMS values, 2+2, would incorrectly produce 4 g.
The equal contributions also show why peak density alone is insufficient: one band is four times lower but four times wider. Area must be evaluated with frequency and density in their linear units. A rectangle measured on a logarithmic drawing does not directly represent this integral. Our teaching profile uses flat bands with explicit edges; it is not an interpolation of the paper’s actual breakpoint table.
If every density value is multiplied by four while the band edges remain fixed, mean square becomes 32 g² and RMS doubles to about 5.657 g. Conversely, halving RMS requires one quarter of the density at every frequency. A phrase such as “half level” must specify whether it means density, RMS or some other quantity. Doubling test duration does not by itself change the specified RMS, although exposure duration can affect fatigue and the evidence collected.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Apply the response at each frequency
For an ideal linear response model, output spectral density is input spectral density multiplied by the squared magnitude of the transfer function. Here the transfer function relates output acceleration to input acceleration, so its magnitude is dimensionless. Assume a piecewise constant magnitude of 3 in the 100–200 Hz band and 1 in the 200–600 Hz band. These are invented band gains, not a fitted ELITE resonance.
Profile A, the earlier example, produces output mean square 3²×4+1²×4=40 g² and RMS √40≈6.325 g. Profile B instead assigns input areas of 1 and 7 g² to the same two bands. It has the same 8 g² input total and 2.828 g input RMS, but output mean square is 3²×1+1²×7=16 g², giving 4 g output RMS. Equal input RMS therefore need not mean equal response. Multiplying by gain rather than gain squared would confuse amplitude and mean-square quantities.
Band areas determine RMS; squared gain determines response
Original two-band spectrum and ideal piecewise response. Density is integrated over frequency before taking RMS; output density uses squared amplitude gain. These are not qualification instructions or measured ELITE profiles.
Open full-size diagram in a new tab: Band areas determine RMS; squared gain determines responseCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Combine spectral evidence with functional evidence
Before comparing measured profiles, retain axis, mounting, control and response sensor locations, bandwidth, averaging and duration. Narrow response features can disappear into coarse frequency bins, while a finite sample makes spectral estimates fluctuate. A missing high-frequency band can also omit real response. The handbook’s measurement discussion separates these limitations; increasing one overall number does not repair an unobserved portion of the spectrum.
An original review might find similar resonance frequencies before and after exposure but a failed valve-command check. The structural comparison does not overrule that functional failure. Conversely, a nominal command test does not establish that the required vibration profile was delivered. Record the measured input, response and function together, investigate discrepancies and retest affected configurations. These examples explain how to interpret a test record, not how to certify ELITE, infer a flight lifetime or prescribe a shaker test for real hardware.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Aliena: vibration profiles and test outcomesSection IV.B.2 and Figures 8–10. Published profiles are context, not the numerical profiles used in the exercises.
- Read: NASA: vibration fundamentalsComplete Section 3.2.3.5, printed pages 3-28 to 3-30, and the response equation 3.94 with Figure 3.33. Original band models use explicit assumptions.