Lesson 1 of 3 · Plasma selection and energy-per-charge inference
Recover a retarding-current spectrum
18 minute lesson · 3 checks along the way
Your goal for this lessonRecover an energy-per-charge current distribution from retarding thresholds and test how bin widths and voltage calibration affect it.
In this lesson 4 sections · 3 checks
Read & understand
Select charged particles before interpreting a magnetic field
Europa Clipper’s PIMS instrument will characterize charged particles near Europa because plasma currents contribute to the magnetic environment that the mission seeks to interpret. Four Faraday cups collect electrical current; biased grids select particle energies, and segmented collectors provide directional information. This is a local plasma measurement that supports magnetic sounding, rather than a direct reading of ocean depth. As of 6 November 2026, NASA’s timeline still places Jupiter arrival in April 2030; launch and the March 2025 Mars flyby are completed milestones.
Build an original idealized cup containing only positive ions arriving perpendicular to its grids. Let u = E/q be kinetic energy per charge, expressed in volts. An ideal retarding threshold V passes ions with u greater than V. Assume a steady distribution, calibrated thresholds, constant collection efficiency, no electron contribution and no uncorrected spacecraft potential. Define j(u) as collected current per volt, already including charge and efficiency. It is not a particle number density or a magnetic-field component.
Read & understand
Difference cumulative measurements to recover energy intervals
The model’s cumulative current is I(V) = B + ∫ from V to infinity j(u) du, with constant background B. Invent currents of 132, 112, 52 and 12 picoamperes at thresholds 0, 100, 300 and 600 volts. Assume no ions above 600 volts, so the final reading supplies the 12-picoampere background. Subtract adjacent readings: 20 picoamperes belong to 0–100 volts, 60 to 100–300 volts and 40 to 300–600 volts. Each difference removes the same background without subtracting it twice.
These intervals have different widths. Divide each integrated current by its width to obtain average current densities of 0.2, 0.3 and approximately 0.133333 picoamperes per volt. The last interval contains twice the first interval’s total current, yet its average density is smaller because it spans three times as much energy per charge. Assume j is uniform within each interval only when predicting intermediate thresholds. Without that additional assumption, the measurements determine interval integrals, not all structure inside them.
Europa Clipper in JPL’s Space Simulator in February 2024 before thermal-vacuum testing. This photograph records environmental qualification on Earth, before the mission’s planned Europa encounters.
Look closely
Does this photograph establish an instrument measurement at Europa?
See what to notice
No. It documents environmental testing on Earth in February 2024. Flight calibration and destination measurements require their own evidence.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Predict a narrower selection window and a shifted threshold
A difference between ideal thresholds at 100 and 200 volts selects a 100-volt window inside the middle interval. Uniform j = 0.3 gives 30 picoamperes. Narrowing the window to 125–175 volts gives 15 picoamperes: finer selection admits less current. Actual PIMS uses a sinusoidally modulated grid and synchronous detection, with a calibrated response rather than this rectangular endpoint-difference filter. Its instrument paper explains the corresponding resolution-versus-signal tradeoff; the numerical values here are not flight settings or a reproduction of its processing.
Now suppose calibration says effective thresholds are 20 volts below their commanded values. A nominal 100–300-volt window actually accepts 80–280 volts. It collects 20 × 0.2 = 4 picoamperes from the first interval and 180 × 0.3 = 54 from the second, totaling 58. Correcting a voltage scale changes which particles enter the interval, not merely the label printed beside a fixed current. This prediction assumes the original piecewise distribution is unchanged during the measurement.
Recover a spectrum from retarding thresholds
Recover interval-integrated current before comparing spectral densities. All currents and windows are fictional; particle identity and number density need additional assumptions.
Open full-size diagram in a new tab: Recover a spectrum from retarding thresholdsCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Separate the recovered observable from a plasma identity
For an alternate distribution, thresholds 0, 200, 500 and 800 volts give currents 184, 144, 24 and 4 picoamperes. The adjacent differences are 40, 120 and 20, and the interval densities are 0.2, 0.4 and about 0.066667 picoamperes per volt. A 300–450-volt window therefore gives 60 picoamperes; a 337.5–412.5-volt window gives 30. If effective thresholds are instead 30 volts above commands, a nominal 200–500-volt window selects 230–530 volts and gives 108 + 2 = 110 picoamperes.
A recovered u does not uniquely identify an ion. A singly charged particle with 100 electronvolts and a doubly charged particle with 200 electronvolts both have E/q = 100 volts. Converting current to number density also requires charge, velocity and collection geometry. Measurements that increase with rising ideal threshold would contradict this stationary, nonnegative-current model, prompting checks of noise, backgrounds, calibration or plasma variability. PIMS observations become useful through those response models and their connection to other instruments, not through assigning every current feature directly to the ocean.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: PIMS instrument paper: selection and calibrationWestlake and colleagues, 2023: section 3 explains the modulated Faraday cup; sections 6.1–6.3 describe energy sweeps, calibrated thresholds and resolution. The rectangular-window exercise is an original idealization.
- Read: NASA: Europa Clipper timelineLaunch on 14 October 2024 and the 1 March 2025 Mars flyby are completed. As reviewed on 6 November 2026, the December 2026 Earth flyby and April 2030 Jupiter arrival remain future.
- Read: NASA: PIMS and magnetic soundingExplains why plasma measurements and segmented collectors complement the magnetometer’s interior investigation.