Lesson 3 of 3 · GOES-R flare peaks, integrals and gaps
EXIS: measure a flare beyond its peak
16 minute lesson · 3 checks along the way
Your goal for this lessonDistinguish flare class, integrated irradiance and background excess, then bound a missing minute without inventing a quiet interval.
In this lesson 6 sections · 3 checks
Read & understand
Solar photons and local particles are different observations
The Extreme Ultraviolet and X-ray Irradiance Sensors, EXIS, observe the Sun from GOES-R spacecraft. Within EXIS, the X-Ray Sensor, XRS, measures soft X-ray irradiance in two bands. The XRS-B band, nominally 0.1–0.8 nanometres, supplies the quantity used for the familiar GOES flare class. Irradiance is power received per unit area, expressed in W/m². It is neither the Sun’s total emitted power nor the energy absorbed by a particular person or spacecraft component.
Other instruments answer other questions. SEISS measures charged particles near the spacecraft, and the magnetometer measures the local field. Solar images add spatial context. These records complement an X-ray time series, but a large flare class does not itself specify a coronal mass ejection’s arrival time or local particle exposure. Begin the calculation by naming the measured quantity and its units. Only then decide what physical or operational inference the evidence can support.
Read & understand
A flare class summarizes a one-minute peak
For an original five-minute example, take consecutive one-minute mean XRS-B irradiances of 0.4, 1.0, 2.0, 1.0 and 0.4, all multiplied by 10⁻⁵ W/m². Assume all samples are valid and fully cover their respective minute intervals. The peak is 2.0 × 10⁻⁵ W/m², so its class is M2.0. The M scale begins at 10⁻⁵ W/m²; the C and X scales begin at 10⁻⁶ and 10⁻⁴ W/m². This is a peak of minute means, not an instantaneous maximum.
Use the total irradiance for the class. Subtracting a background first would classify a different quantity. The guide also specifies truncating the class coefficient to one decimal place, rather than rounding: 4.29 × 10⁻⁵ W/m² becomes M4.2. A second fictional profile held at 1.2 × 10⁻⁵ W/m² for all five minutes has a lower M1.2 peak. That comparison alone says nothing about which profile delivers the larger irradiance integral over the chosen window.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Integrate the means using their interval durations
A one-minute mean represents the average irradiance during a 60-second interval. Multiply each mean by 60 seconds and add: (0.4 + 1 + 2 + 1 + 0.4) × 10⁻⁵ × 60 = 0.00288 J/m². Watts are joules per second, so multiplying by seconds produces energy per unit area. Because these are interval means, rectangles give the integral implied by the data. They are not instantaneous samples that require an assumed straight line between adjacent points.
Now separately calculate an excess above a stated constant background of 0.2 × 10⁻⁵ W/m². The background contribution over 300 seconds is 0.00060 J/m². Subtract it once from the total: 0.00288 − 0.00060 = 0.00228 J/m². Label this result “background excess.” The user guide’s integrated-flux accumulation adds total irradiances; its reported field should not silently be relabeled as our background-subtracted quantity. A variable or uncertain background would need its own treatment rather than this constant subtraction.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Compare the same window with the lower plateau
For the M1.2 plateau, the total is 1.2 × 10⁻⁵ × 300 = 0.00360 J/m². Using the same background and duration gives 0.00300 J/m² of excess. Both exceed the peaked profile’s corresponding integrals even though the plateau’s maximum is smaller. A brief high peak and a lower sustained signal can reverse their ranking when the question changes from maximum power per area to accumulated energy per area.
Our five-minute window is chosen in advance. It does not implement NOAA’s event-start or event-end detection rules. The flare summary distinguishes the peak, decline to the end criterion and return toward background; those times need not coincide. Real event integrals depend on the event window and processing definition. When comparing two reports, retain their time limits and data versions as well as the numerical values. A shared unit does not guarantee a shared integration interval.
Read & understand
Bound the missing minute instead of setting it to zero
Remove the central sample from the peaked profile. The four observed minutes contribute (0.4 + 1 + 1 + 0.4) × 10⁻⁵ × 60 = 0.00168 J/m² over 240 seconds. Suppose independent information bounds the missing minute’s mean between 1 and 3 × 10⁻⁵ W/m². Its contribution is then between 0.00060 and 0.00180 J/m². The full five-minute total lies between 0.00228 and 0.00348 J/m². The bounds come from that additional assumption, not from the gap itself.
The full-window peak is also uncertain. The surviving maximum is M1.0, and the missing sample could raise the peak as high as M3.0. The original M2.0 cannot be recovered uniquely from the remaining four measurements. Treating the gap as zero would understate even the assumed lower integral bound. Subtracting the full five-minute background from the integral bounds gives excess bounds of 0.00168–0.00288 J/m²; subtracting only four minutes of background would mix coverage definitions.
A peak does not determine an integral
Original fictional minute means over a fixed five-minute window; columns are aligned one-minute intervals and bar areas compare their contributions. Dashed lines mark the constant 0.2 × 10⁻⁵ W/m² background in the complete profiles. The outlined missing interval is a bound, not an observation or an interpolated value. This does not implement operational flare start/end detection.
Open full-size diagram in a new tab: A peak does not determine an integralCheck 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Use quality information before turning a record into evidence
Real minute products carry quality and coverage information, including how many high-cadence observations contributed. An average based on a few usable seconds is not automatically equivalent to a completely observed minute. Interpolation and contamination indicators also matter. A missing or invalid reading during an eclipse or other observing interruption is not evidence that solar activity vanished. Our arithmetic assumes full-minute coverage unless a gap is explicitly introduced; read the product documentation before applying that assumption to an archive file.
NCEI distinguishes operational and science-quality products; retrospective corrections can change the latter. Historical scaling used for earlier GOES instruments must not be applied to GOES-R simply because the files share an XRS name. Keep spacecraft, band, processing version, time window and quality policy attached to any comparison. Report the peak class and integral as different summaries, and keep missing-data bounds visible. If the question concerns particle hazards or an arriving eruption, bring in the relevant observations instead of stretching the X-ray calculation beyond its meaning.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: NCEI GOES-R EXIS data productsFind XRS product definitions, science and operational data distinctions, and the current linked user documentation.
- Read: GOES-R XRS Level 2 Data User Guide, October 6, 2026Read pages 5, 7, 9 and 20 of the October 2026 guide for flare classes, minute coverage, event states and total-irradiance accumulation.
- Read: NCEI GOES-R Space Environment In Situ SuiteCompare local charged-particle measurements with the solar-photon quantity measured by XRS.
- Read: NOAA GOES-R spacecraft and instrumentsLocate the Earth-pointed, solar-pointed and local instruments, including the coronagraph added on GOES-U.