Lesson 1 of 3 · GOES-R radiance and brightness temperature
ABI: convert radiance before interpreting temperature
16 minute lesson · 3 checks along the way
Your goal for this lessonUnpack valid radiances, recover a brightness temperature and explain why a mixed pixel cannot be replaced by its average physical temperature.
In this lesson 6 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
One generation, several different measurements
GOES-R names a generation of NOAA weather satellites as well as its first spacecraft during development. The four spacecraft GOES-R, S, T and U became GOES-16, 17, 18 and 19. NASA develops and launches the satellites for NOAA, which operates them and distributes their observations. The photograph shows the first spacecraft upright at Astrotech before launch. It establishes a physical spacecraft and a processing setting, not the quality of a later weather product.
The generation places different instruments toward different targets. The Advanced Baseline Imager, ABI, and Geostationary Lightning Mapper, GLM, look toward Earth. EXIS and SUVI observe the Sun; SEISS and the magnetometer measure particles and fields locally. GOES-U adds the CCOR-1 coronagraph. ABI has sixteen spectral bands, but those bands do not all represent temperature. This lesson follows a thermal measurement from a stored integer to a brightness temperature, keeping that interpretation separate from the temperature of every object inside the pixel.
GOES-R, later GOES-16, stands upright at Astrotech during launch processing on August 23, 2016.
Look closely
Which evidence does this photograph provide?
See what to notice
It records the GOES-R spacecraft upright during launch processing. Calibrated radiances, product quality and later operational performance require separate instrument records.
Read & understand
Read the quality and packing information first
A packed integer in a radiance product is not necessarily a raw detector count. The file can store a scaled representation of an already calibrated quantity. To unpack it, apply L = s × C + o, where C is the stored integer, s the scale and o the offset. Check the fill value and quality metadata before doing arithmetic. A missing value can otherwise turn into a very large, plausible-looking number that receives a temperature and a color like any real observation.
Use an original exercise with a fill value of 1023 and an expressly strict policy accepting only DQF = 0. The four (C, DQF) pairs are (30, 0), (1023, 0), (42, 2) and (10, 1). Only the first passes both conditions. A good-quality flag does not rescue a fill value. Rejecting conditional DQF = 1 is our chosen exercise policy, not a claim that every conditional real observation is unusable. The user guide’s coefficient tables are examples; actual files supply the coefficients for their instrument and product version.
Read & understand
Turn a valid radiance into a brightness temperature
Now introduce fictional constants to make the conversion visible. Let U denote an arbitrary radiance unit and T a temperature in kelvin. Our simplified thermal model is L(T) = 1000 / [exp(1200/T) − 1] U. Its inverse is T(L) = 1200 / ln(1 + 1000/L) K when L is a positive number expressed in U. The ratio inside the logarithm is dimensionless: the numerator’s radiance scale and L use the same units. These are teaching constants, not ABI band coefficients.
For the valid stored value C = 30, use s = 0.5 U per integer step and o = 1 U. Unpacking gives L = 0.5 × 30 + 1 = 16 U. The inverse then gives approximately 289.1 K. Applying the inverse directly to 30 would skip unpacking and answer a different question. In the real emissive-band conversion, file-specific Planck and band-correction coefficients matter. The derived brightness temperature describes the blackbody-equivalent radiance for that band; it does not by itself prove a physical surface or cloud temperature.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Mix the radiances before converting the mixture
Imagine a single pixel containing two ideal blackbody patches in the same band, with equal response weighting, no intervening atmosphere and no reflected contribution. One patch is at 240 K and the other at 300 K. The fictional forward model gives radiances of approximately 6.78365 U and 18.65736 U. For equal areas, the measured mixture is (6.78365 + 18.65736)/2 = 12.72051 U. Convert that mixture once: its brightness temperature is approximately 274.1 K.
The arithmetic temperature average is 270 K. It differs because the forward radiance function is nonlinear: the warmer patch contributes disproportionately to the signal. Neither a more detailed color palette nor an extra decimal place fixes the order of operations. The 274.1-K value also does not reveal that the pixel contains two patches. A uniform ideal patch at the same brightness temperature would produce the same radiance in this model. Additional bands or observations may constrain a scene, but one measured number cannot describe every unresolved component.
Mix radiances, then invert
Original fictional coefficients and radiance unit U. The same-band patches are ideal blackbodies with equal weighting, no atmosphere and no reflected contribution. Only valid, non-fill packed data enter the conversion. The mixture’s brightness temperature does not identify every physical component.
Open full-size diagram in a new tab: Mix radiances, then invertCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Recover an area fraction only with known endpoints
If the two endpoint radiances are independently known, write Lmix = (1 − f) × Lcold + f × Lwarm, where f is the warm area fraction. Rearranging gives f = (Lmix − Lcold)/(Lwarm − Lcold). In the example, (12.72051 − 6.78365)/(18.65736 − 6.78365) is approximately 0.5. Use the radiances in this calculation. Interpolating between 240 K and 300 K using 274.1 K would incorrectly assign about 57% to the warm patch.
This fraction depends on more than algebra. If the endpoint temperatures are unknown, many endpoint-and-fraction combinations can reproduce the same mixture. Different emissivities, atmospheric absorption, viewing geometry or response weighting also change the relationship. Identical endpoints make the denominator zero and erase information about the fraction entirely. The result is a conditional inference under the specified two-component model, not a general retrieval of cloud cover from any infrared temperature image.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
A changed conversion is not automatically a changed scene
Suppose the original integer remains 30 but a reviewed processing version changes the scale from 0.5 to 0.4, retaining the 1-U offset. Recompute the radiance: 0.4 × 30 + 1 = 13 U. The fictional inverse now gives about 275.5 K. The arithmetic has changed even though the stored integer has not. Whether the new calibration is more accurate requires validation; a downward change in the reported temperature alone does not demonstrate that the observed scene cooled.
Preserve the spacecraft, band, times, quality decisions, units and processing version with the result. A NOAA notice in May 2023, for example, identified a planned correction to Planck-coefficient metadata. It illustrates why a historical table should not be copied without its context. For a scientific comparison, first establish that both values describe compatible quantities. Then discuss physical changes, with atmosphere, emissivity, unresolved mixtures and uncertainty still visible in the explanation.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: NOAA GOES-R series mission and agency rolesFollow the spacecraft names and the respective NASA and NOAA roles in the GOES-R generation.
- Read: NOAA GOES-R spacecraft and instrumentsLocate the Earth-pointed, solar-pointed and local instruments, including the coronagraph added on GOES-U.
- Read: NOAA Advanced Baseline ImagerCompare the ABI spectral bands and the different observing tasks they support.
- Read: GOES-R Product Definition and Users Guide, Volume 4, GRBRead PDF pages 94, 101 and 102 for radiance conversion, packing, quality flags and the warning that table coefficients are examples.
- Read: NOAA planned GOES-16/18 software update, May 22, 2023Read the planned May 2023 metadata correction as a reason to retain product version and units, not as new numerical calibration constants.