Lesson 2 of 3 · Spectral sampling, aliasing and finite windows
Separate sampling from resolution
25 minute lesson · 3 checks along the way
Your goal for this lessonDistinguish sampling interval from scan extent and explain the tradeoff between sidelobes and resolution.
In this lesson 4 sections · 3 checks
Read & understand
Choose a coordinate that describes the fringes
An interferogram is sampled against optical path difference, written δ. Wavenumber σ is the reciprocal of wavelength: σ=1/λ. Using micrometres for λ gives inverse micrometres for σ. For example, 0.5 µm corresponds to 2 µm⁻¹. The phase of an ideal fringe is 2πσδ, so the product σδ must be dimensionless.
Use a general ideal Fourier-spectroscopy model to explore two distinct choices: the interval Δδ between samples and the maximum path difference L covered. Neither is inferred from the frame count alone. In a moving-scene system, the optical calibration and point trajectory determine which path differences were sampled. The following values are original exercises, not Kent Ridge instrument settings or a reconstruction of its flight software.
Read & understand
Fine spacing prevents different fringes from looking alike
Suppose uniformly spaced samples must represent all wavenumbers from zero to 2.5 µm⁻¹. For this baseband model, the Nyquist boundary is Δδ=1/(2×2.5)=0.2 µm. Choosing 0.16 µm stays below that boundary. Filtering and calibration are still required: this spacing does not make unwanted light outside the assumed range disappear. Equality at the boundary also leaves no margin and can lose phase information.
At the coarser interval Δδ=0.25 µm, a cosine at 2.5 µm⁻¹ and one at 1.5 µm⁻¹ give identical values at every integer sample index n: cos(2π×2.5×0.25n)=cos(2π×1.5×0.25n). Their wavelengths, 0.4 µm and about 0.667 µm, are different. This is aliasing. Collecting more samples at that same spacing cannot distinguish these two ideal cosines without additional information or a change to the acquisition.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Longer coverage narrows the instrument’s line shape
Now assume adequate sampling and a symmetric interferogram measured from −L to +L. Truncating the sequence with a rectangular window gives a sinc-shaped line response. Define the nominal separation scale here as the distance from its peak to its first zero: Δσ=1/(2L). For L=20 µm, that scale is 0.025 µm⁻¹. It is a stated line-shape criterion, not the spacing of points drawn on a graph.
Multiplying the same data by a triangular window reduces sidelobes but doubles this first-zero scale to 1/L=0.05 µm⁻¹. Two ideal lines separated by 0.04 µm⁻¹ exceed the rectangular scale but not the triangular one. This comparison alone does not guarantee that noisy, unequal or blended real features can be distinguished. First-zero separation, full width at half maximum and channel spacing are different quantities; name the one being used.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
More plotted points do not replace more measured information
With triangular weighting, extending the maximum path difference to L=40 µm brings the first-zero scale back to 0.025 µm⁻¹. That requires additional measured coverage and a sufficiently stable scene. In contrast, adding zeros to the end of an already recorded sequence can make a transform plot smoother while leaving the measured path extent unchanged. It cannot recover fringes that were never observed.
A useful planning sequence is therefore to choose an allowed spectral range, verify the sampling and filtering needed for it, choose a measured path extent for the desired line-shape scale, and state the window. CFHT’s SITELLE documentation provides these general Fourier relationships for its own instrument. Kent Ridge’s crystal optics and moving scene differ from SITELLE’s scanning Michelson; the equations here are a transparent teaching model, not a claim that the two instruments share hardware or processing.
Distinguish sampling aliases from line width
Original cosines use equal amplitude and zero phase. The first-zero criterion is explicit and differs from full width at half maximum. These are general models, not Kent Ridge specifications.
Open full-size diagram in a new tab: Distinguish sampling aliases from line widthCheck 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: CFHT: imaging Fourier transform spectroscopyGeneral interferogram, aliasing and window relationships. The lesson explicitly uses the symmetric-window first-zero criterion, not an unspecified resolution number or Kent Ridge performance.
- Read: DSO: PolarFour measurement principlePrinted pages 128–129 establish the moving-scene crystal-optic context. The numerical sampling and window examples are original.