Lesson 2 of 4 · Shared supply and startup current
Turn current into bus voltage
18 minute lesson · 3 checks along the way
Your goal for this lessonApply a declared source-resistance model to steady and startup load currents, with consistent units.
In this lesson 3 sections · 3 checks
Read & understand
Declare the source and the loads
Use an ideal 5 V source behind a lumped 0.25-ohm resistance. The resistance represents a simplified shared voltage drop; it is not a detailed battery or wiring model. Essential platform loads draw 0.4 A throughout the exercise. Payload A draws 1.1 A for its first 2 milliseconds, then 0.3 A. Payload B draws 1.3 A for its first 3 milliseconds, then 0.4 A. Each draws zero before its commanded start.
Treat those currents as prescribed profiles over an eight-millisecond observation interval. Their values do not change with bus voltage in this simplified experiment. We omit capacitors, inductors, converter control, temperature and battery discharge. NASA’s 2017 draft hosted-payload interface guidance discusses startup currents, voltage excursions and protection, but its numerical limits concern a different setting. It motivates checking an interface; it does not supply KNACKSAT requirements.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
One shared drop affects every load
At each instant, add the platform and active payload currents. Ohm’s law gives the shared drop as resistance times total current: Vbus = Vs − R × Itotal. Amperes multiplied by ohms give volts. Once both payloads have settled, the total is 0.4 + 0.3 + 0.4 = 1.1 A. The drop is 0.275 V, leaving a bus voltage of 4.725 V.
Now command both payloads to start at time zero. For the first 2 milliseconds, total current is 0.4 + 1.1 + 1.3 = 2.8 A. The drop becomes 0.7 V and the bus falls to 4.3 V. A settled-current calculation would miss this excursion. The same shared drop reaches both payload interfaces in this model, even though each team designed only its own experiment.
A shared drop reaches every load
Original fictional circuit abstraction, not KNACKSAT wiring or flight values. Common return is omitted; all loads share the shown node. Current profiles are prescribed independently of voltage.
Open full-size diagram in a new tab: A shared drop reaches every loadRead diagram data as a table
| Element or state | Value | Meaning |
|---|---|---|
| Source | 5 V | Ideal fixed source |
| Shared resistance | 0.25 ohm | Lumped source and path drop |
| Platform | 0.4 A | Always active |
| A | 1.1 A for 2 ms; then 0.3 A | Zero before commanded start |
| B | 1.3 A for 3 ms; then 0.4 A | Zero before commanded start |
| Simultaneous startup | 2.8 A; 4.3 V | Shared voltage below 4.5 V minimum |
| Settled | 1.1 A; 4.725 V | Startup peak no longer present |
Original fictional circuit abstraction, not KNACKSAT wiring or flight values. Common return is omitted; all loads share the shown node. Current profiles are prescribed independently of voltage.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Follow the changes rather than averaging them away
At 2 milliseconds, A settles to 0.3 A while B still draws 1.3 A. Including the platform load, total current becomes 2 A and voltage becomes 4.5 V. At 3 milliseconds, B also settles, returning the bus to 4.725 V. These intervals form a trace: 4.3 V from 0 to 2, 4.5 V from 2 to 3, and 4.725 V afterward.
We assign each change to the interval beginning at that time. Thus A is already settled at exactly 2 milliseconds. The exercise’s voltage requirement is at least 4.5 V, with equality permitted. The simultaneous start violates that requirement for two milliseconds. This finding concerns the declared voltage envelope, not physical damage or a measured failure aboard a spacecraft. Averaging voltage over the full interval would hide the boundary violation.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: NASA-hosted 2017 draft: hosted-payload interface comparisonMarch 23, 2017 DRAFT hosted-payload guidance, sections 2.2.3–2.2.4: startup currents, undervoltage response and fault propagation require interface consideration. General comparison only; its 28V numerical limits are not KNACKSAT requirements or current certification standards.
- Read: Project team: preliminary KNACKSAT-2 platform presentationProject team presentation by Phongsatorn Saisutjarit: shared bus, user-developed payloads and up to ten slots; preliminary design context. Do not treat its planned launch date or technical table as verified final flight specifications.