Lesson 1 of 3 · Mars Science Laboratory
Distinguish crystal spacing from angular offset
18 minute lesson · 3 checks along the way
Your goal for this lessonUse calibrated diffraction angles and several reflections to test a lattice-spacing change against an angular-offset hypothesis.
In this lesson 4 sections · 3 checks
Read & understand
Read structure through a powder pattern
Curiosity brought a mineral laboratory to Gale Crater. CheMin directs X-rays through powdered material and records diffraction patterns associated with ordered atomic structures. Its instrument paper describes converting rings on a detector into intensity versus scattering angle, then comparing complete patterns with candidate minerals. This gives structural evidence that an elemental inventory alone cannot supply. The same ingredients can occur in different atomic arrangements, while a mixture can produce overlapping features from several minerals.
This lesson constructs an original, deliberately simplified diffraction experiment. Use a single wavelength λ = 0.180 nanometre and first-order diffraction, n = 1. These rounded values and invented peaks are not CheMin measurements. Bragg’s law is nλ = 2d sin θ, where d is spacing between a family of crystal planes and θ is the glancing angle to those planes. A diffraction plot reports the scattering angle 2θ, so the angle must be halved before using the sine.
Read & understand
Calibrate the angle before solving for spacing
A reference material has a known peak at 2θ = 30.0°, but the instrument reports 30.4°. Assume, solely for this exercise, that every reported angle has the same additive offset δ. The reference estimates δ = +0.4°, so subtract 0.4° from each sample peak. Recorded sample peaks at 20.4°, 30.4° and 40.4° then become 20°, 30° and 40°. An offset on the reported 2θ axis must be corrected on that axis before halving it; subtracting 0.4° from θ instead would overcorrect.
Apply d = λ/[2 sin((2θ)/2)] using degree-valued angles. The corrected peaks correspond to spacings about 0.518289, 0.347733 and 0.263142 nm. For the first peak, sin 10° belongs in the denominator, not sin 20°. These are three plane spacings, not three grain diameters. Matching several spacings can test a proposed phase, but these three invented numbers alone cannot establish a real mineral identity. Intensities, overlapping phases, missing reflections and the instrument response still matter in an actual powder analysis.
Curiosity’s MAHLI camera recorded the John Klein sample hole and a nearby shallower test hole on Sol 182. The deeper hole supplied powdered rock for analysis inside the rover. This complete published photograph documents sampling work; the powder’s mineral structure requires separate instrument measurements.
Look closely
Can the visible powder identify a mineral’s atomic structure by itself?
See what to notice
No. The image records the sampling site and texture. Diffraction patterns, calibration and several matched reflections supply the structural evidence.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Make a physical change predict every reflection
Now compare an unchanged reference pattern at 20°, 30° and 40° with a second hypothetical sample. Assume its corresponding plane spacings all increase by the same factor s = 1.02, with unchanged wavelength and diffraction order. Bragg’s law predicts sin θnew = sin θold/s. The new scattering angles are 2 arcsin[sin θold/1.02], giving approximately 19.603932°, 29.398367° and 39.183250°. Larger spacing moves each peak to a smaller angle, but the shifts are not equal in degrees.
A competing explanation attributes the first peak’s shift to an instrumental offset of −0.396068°. Applied to the whole reference pattern, that predicts 19.603932°, 29.603932° and 39.603932°. It matches the first feature exactly and misses the next two by about 0.206° and 0.421°. If each observed peak has an invented hard tolerance of ±0.03° and the reference values are exact, only the stated expansion hypothesis fits all three. This comparison distinguishes two constructed models; it does not prove the cause of a physical expansion or rule out every other calibration error.
One angular offset does not mimic every spacing change
The same first peak shift can fit two different explanations. Their predictions separate across a wider angular range. All peaks, offsets, tolerance and spacing changes are invented; the test is not a CheMin flight-calibration algorithm.
Open full-size diagram in a new tab: One angular offset does not mimic every spacing changeCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Reverse the change and preserve the inference
An alternate sample contracts every corresponding spacing by s = 0.98. The same formula predicts 20.412491°, 30.627090° and 40.852344°. A constant offset fitted to the first feature, +0.412491°, would instead predict 20.412491°, 30.412491° and 40.412491°. Again, the higher-angle peaks discriminate the hypotheses. For any matched reflection, s can also be recovered as sin θold/sin θnew. Agreement among several recovered factors tests the assumed uniform scaling; disagreement calls for a different structural or calibration model.
Real CheMin interpretation uses standards, peak shapes and fuller patterns rather than this three-line shortcut. The instrument paper also distinguishes broad scattering from poorly ordered material from sharper crystalline reflections, so unresolved intensity cannot simply be assigned to a missing named mineral. NASA’s October 2026 Curiosity update reported imaging at the Nazca target and preparations for another drill campaign. Those images demonstrate continued investigation; planned analyses in that account are not completed mineral identifications.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: CheMin instrument characterization and calibrationBlake and colleagues, 2012: printed pages 345–346, 374–375 and 381–382 describe powder patterns, standards, full-pattern interpretation and limits of individual reflections.
- Read: NASA Glenn: Bragg’s law and measured scattering angleApril 2023 presentation, slides 11–13: Bragg’s law, the measured 2θ angle and characteristic X-ray wavelengths. The numerical exercise uses a stipulated rounded wavelength.
- Read: NASA: Curiosity prepares to drill at NazcaPublished 28 October 2026, with 16 October planning context and an 18 October acquired image; planned drilling and analyses remain distinct from reported observations.