Lesson 3 of 3 · Calibration changes in radar time series
Compare calibration epochs
24 minute lesson · 3 checks along the way
Your goal for this lessonSeparate a measured brightness change from a processing-scale change and test whether a correction transfers across viewing geometry.
In this lesson 4 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
A time series can contain a processing step
A pathfinder and its proposed successors create a new comparison problem: measurements acquired at different times or by different spacecraft must share a defensible scale. In February 2026, ST Engineering announced plans for four NeuSAR-2 satellites by 2030, with the first scheduled for 2027. Those are development statements. They do not establish a deployed constellation, a shared calibration or continuity with the original NeuSAR data.
Schmidt and colleagues studied a concrete example in Sentinel-1: updates to antenna-pattern and processing gains introduced artificial steps in backscatter time series. They used the recorded old and new parameters to place products on a consistent basis. That is methodological evidence from another system. Our following scalar model teaches how a scale change can hide or exaggerate change without claiming such a fault occurred in NeuSAR.
Read & understand
Undo the old scale before comparing
Define observed brightness y=cP, where P is the underlying linear brightness and c is a positive multiplicative processing scale. At the first date, P₁=0.20 and c₁=1.25, so y₁=0.25. At the second, P₂=0.25 and c₂=2, so y₂=0.50. The observed ratio y₂/y₁ is 2, suggesting a doubling. Restoring the common scale gives (y₂/c₂)/(y₁/c₁)=0.25/0.20=1.25: a 25% increase.
In decibels, the observed difference is 10 log10(2)≈3.01 dB. The scale contribution is 10 log10(2/1.25)≈2.04 dB. Subtracting it leaves approximately 0.97 dB, equal to 10 log10(1.25). For conversion to any chosen reference scale c_ref, use y_ref=y×c_ref/c. Multiplying by the old scale again would strengthen the error instead of removing it.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Test whether one factor is enough
Suppose stable reference regions at near and far viewing positions are observed in two epochs. Their old-to-new observation ratios are 1.2 near and 1.5 far, despite unchanged underlying returns. A correction inferred only from the near region divides all new observations by 1.2. It repairs the near comparison but leaves the far ratio at 1.5/1.2=1.25, an artificial 25% increase.
This example has a position-dependent scale change, so one scalar cannot fix the whole image. Test the transfer by angle, beam, mode and polarization using suitable references, rather than assuming one successful correction applies everywhere. A constant reference also needs evidence of stability: changed moisture, geometry or its physical condition can alter its return. Matching a mean value alone cannot identify which mechanism caused a difference.
Remove a processing-scale change before interpreting a trend
Original multiplicative model and independent viewing-position example. Real products may require several gains with distinct conventions.
Open full-size diagram in a new tab: Remove a processing-scale change before interpreting a trendCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Decide what the remaining difference supports
For a final interval example, suppose the observed brightness ratio is 1.20 and the multiplicative scale ratio c₂/c₁ is bounded by 1.10–1.30. The corrected ratio lies between 1.20/1.30≈0.923 and 1.20/1.10≈1.091. Because that range contains one, the stated information does not establish the direction of change. It also does not establish that nothing changed. Additional uncertainty or viewing differences could widen the interpretation further.
Retain acquisition and processing dates separately, along with product versions, applied gains and the reference conditions used to validate a comparison. The published Sentinel-1 method uses several differently defined gains and mission-specific annotations; its full equation cannot be replaced by our single c without checking those conventions. For NeuSAR or a future constellation, first obtain the actual product definitions and validation evidence, then decide what physical inference the comparable returns support.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Schmidt and colleagues: radiometric re-compensationComplete 15-page primary paper read; equations and Figures 3–6 reviewed in renders. The original scalar exercises are not the Sentinel-1 or NeuSAR flight-processing implementation.
- Read: ST Engineering: NeuSAR-2 development plansFebruary 2, 2026 announcement. Four satellites through 2030 and a first launch in 2027 are plans, not accomplished deployment or calibrated performance.