Lesson 1 of 3 · Response width and sidelobe energy
Measure a point response
23 minute lesson · 3 checks along the way
Your goal for this lessonMeasure half-power width and distinguish a peak sidelobe from total sidelobe energy.
In this lesson 4 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
From first image to measured quality
NeuSAR launched with DS-EO and SCOOB-I on June 30, 2022. DSO led the radar pathfinder with NUS research teams, Satrec Initiative from South Korea and MMA Design from the United States. The September 2022 DSO/OSTIn release reported a first image eight days after launch and presented dated Singapore and Phuket scenes. Those images demonstrate a mission milestone; a display alone does not supply a complete image-quality measurement.
A focused point target spreads into a response with a central peak and surrounding lobes. Its shape is useful because an isolated, well-characterized reference provides a controlled comparison. Here we measure invented responses after focusing. We do not infer NeuSAR’s processing settings, calibration accuracy or current operation. The preserved photograph of the shared PSLV-C53 launch audience supplies historical context, with its separate DS-EO archive ownership retained.
Visitors watch PSLV-C53 at Sriharikota on June 30, 2022. The launch carried NeuSAR, DS-EO and SCOOB-I. This complete DOS/ISRO photograph records the shared launch audience, not a radar image or an image-quality test.
Look closely
Which part of NeuSAR’s story can this photograph directly show?
See what to notice
It shows people watching the shared PSLV-C53 launch. It does not show the radar payload, a returned radar scene or a calibrated point response. Its DS-EO archive owner and DOS/ISRO credit remain attached.
Read & understand
Find the half-power crossings
Use a one-dimensional, background-subtracted power profile with its maximum at x=0. At x=0, ±1 and ±2 metres, the powers are respectively 100, 60 and 20 arbitrary units. For this exercise, connect adjacent samples by straight lines. Half the peak power is 50. On the positive side, the profile falls from 60 to 20 over one metre, so reaching 50 takes (60−50)/(60−20)=0.25 of that interval. The crossing is x=1.25 m.
Symmetry puts the other crossing at −1.25 m, giving a full half-power width of 2.5 m. Half power corresponds to 10 log10(0.5), approximately −3.01 dB, commonly called the −3 dB width. Real analysis uses suitable interpolation and evaluates both range and azimuth. This width is neither the one-metre sample spacing nor a measure of absolute map-position error. Interpolating more points does not create independent detail.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Measure the largest sidelobe and all sidelobes
State the ratio convention before comparing numbers. We use PSLR = 10 log10(Pside,max/Pmain,max). A peak power of 100 and a largest sidelobe power of 1 give −20 dB. This is equivalently a sidelobe amplitude one tenth of the main amplitude. Applying 20 log10 directly to the power ratio would incorrectly give −40 dB. Some documents describe the reciprocal ratio; the sign and denominator must travel with the reported value.
For a separate two-dimensional integration example, let main-region energy be 200 and the surrounding side-region energy be 20, using the same area weighting. Define ISLR = 10 log10(Eside/Emain), which is −10 dB. PSLR checks the strongest individual sidelobe; ISLR checks their accumulated energy over explicitly chosen regions. Changing the outer region can change ISLR even when the response itself is unchanged.
Half-power width is measured between two crossings
Original linear-interpolation profile. Sidelobe examples use separate specified measurements and a side-to-main ratio convention.
Open full-size diagram in a new tab: Half-power width is measured between two crossingsCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Compare complete measurements
Imagine processor A gives PSLR −20 dB and ISLR −10 dB, while processor B gives −25 dB and −8 dB under identical region definitions. B has the smaller worst sidelobe but a larger relative total sidelobe energy: about 0.158 rather than 0.100. A single “better” label would hide that tradeoff. The response width must also be checked because spectral weighting can trade narrower detail for lower sidelobes.
A real reference target needs sufficient contrast against its surroundings. Nearby scatterers and an incorrect background estimate can contaminate the result. Keep the acquisition mode, polarization, pixel spacing, interpolation method, analysis regions and processing version with the measurement. Aresys’ point-target documentation makes these operations explicit. Our small profiles illustrate the arithmetic, not its full software implementation or a NeuSAR acceptance threshold.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: DSO: NeuSAR launch and partnersDated July 2022 launch and first-contact announcement; not evidence of present service availability.
- Read: DSO/OSTIn: NeuSAR imagery milestoneSeptember 16, 2022 release and dated scene captions. The complete five-page release and its three scene figures were reviewed; displayed images do not establish calibration accuracy.
- Read: Aresys: point-target analysis algorithmsResolution estimation and explicit negative-dB sidelobe formulas. General methods; not NeuSAR processor documentation.