Lesson 2 of 3 · Current, particle flow and plume direction
Sum axial plume momentum
23 minute lesson · 3 checks along the way
Your goal for this lessonCombine already integrated ion-current regions with their velocities and directions, while distinguishing a plume estimate from total measured thrust.
In this lesson 5 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
A local probe samples only part of the exhaust
The MUSIC concept paper describes another route to a thrust estimate: combine ion-current and energy measurements across a plume. Its newer MUSIC-SI experiment used a Faraday cup and a retarding-potential analyzer. This was a ground measurement on a different version, not a report of NuX-1’s on-orbit thrust. The authors noted that moving probes too close could disturb the experiment, while weak signals farther away limited the measurements.
A Faraday probe measures collected electric current. After appropriate corrections, current density describes charge crossing a unit area per second. One reading at the bright centre does not represent the whole plume. The surface areas and directions represented by the measurements are essential. Brown and colleagues’ measurement guidance separates total beam current from its axial contribution and explains why facility conditions and measurement geometry matter.
Read & understand
Convert charge flow into momentum flow
For singly charged ions of one species, an integrated current I corresponds to I/e ions per second, where e is the elementary charge. If each ion has mass m and speed v, its momentum is m×v. The momentum rate in a direction making angle θ with the intended thrust axis contributes Fz=I×(m/e)×v×cosθ. This model assumes outward-moving ions, known speeds and corrected currents; it omits neutral momentum and other contributions.
Use the rounded teaching value m/e=1.36×10⁻⁶ kilograms per coulomb and a common speed of 20,000 metres per second. One milliampere then represents 27.2 micronewtons of momentum rate before direction is considered. We will supply already integrated currents for entire annular regions. Do not multiply them by a probe area or by two again. Raw current-density samples would first need their represented surface areas and a justified treatment of the unsampled spaces.
Read & understand
Weight each region before adding
Take three regions carrying 1, 2 and 1 milliamperes. Their current-weighted mean cosines are respectively 1, 0.8 and 0.6. With the same speed everywhere, the axial weighted current is 1×1+2×0.8+1×0.6=3.2 milliamperes. The model gives Fz=3.2×27.2=87.04 micronewtons. Using the total current of 4 without direction gives 108.8 micronewtons and overstates the axial result.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Normalize the weighted direction
The angular factor is 3.2/4=0.8 for this uniform-speed model. An ordinary average of the three cosines also happens to be 0.8 here, but that coincidence is not a method. If the currents become 1, 1 and 2, the weighted factor is (1+0.8+1.2)/4=0.75, although the unweighted average remains 0.8. The measurement represents particle transport, so regions with different current cannot automatically receive equal weight.
Ion current needs velocity and direction to estimate axial momentum
Original supplied-region model. Currents already include the represented area; the coefficient uses the lesson’s rounded ion mass-to-charge ratio.
Open full-size diagram in a new tab: Ion current needs velocity and direction to estimate axial momentumCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Preserve velocity information and missing-region bounds
Return to the original currents, but halve only the outer region’s speed to 10,000 metres per second. Its contribution falls from 16.32 to 8.16 micronewtons. The total becomes 78.88. A current-only angular factor cannot capture that change. If an energy measurement is used to obtain speed, use the appropriate ion mass and charge state; doubling kinetic energy increases speed by √2, not by two.
Suppose an unmeasured outward region is independently bounded by I≤0.5 milliamperes, v≤20,000 metres per second and 0≤cosθ≤0.2, using the same species. Its possible axial addition is at most 0.5×27.2×0.2=2.72 micronewtons. Without those bounds it cannot simply be called zero. Different charge states, asymmetric flow, background particles or neutral exhaust require a richer model. Comparing a plume estimate with a calibrated force balance is useful precisely because their errors and assumptions differ.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Laterza and colleagues: direct and plume-based estimatesSection III.B describes limitations of two ground measurement approaches. No performance value is transferred to NuX-1 or later MUSIC-HM.
- Read: Brown and colleagues: Faraday-probe practiceSelected far-field analysis, printed pages 594–596, equations 8–15 and Figures 18–24 reviewed. The course uses supplied integrated regions rather than reproducing the paper’s finite-source corrections.